3. Transmitters: Wireless components like remotes. The signals of these
components will be received by a controller with transceiver
functionality (IRRF 7243, TM13 or console of a Marmitek
Security System).
The Transceiver will translate the signals into Marmitek X-10
signals on the power line.
Addresses
Up to a maximum of 256 different addresses can be preset. These are
subdivided into a so-called HouseCode (A to P incl.) and a UnitCode (1 to 16
incl.). The HouseCode can also be set on the controllers, so that the
controllers and modules become part of the same system. The address can be
set either using code dials or by pressing buttons, depending on the type of
module.
The Marmitek X-10 System uses standard commands, which control all units
with the same HouseCode at the same time (e.g. all lights on, all off, etc.).
Signal Range
Range of Marmitek X-10 signals over the Power Line and how to
increase the range.
The Marmitek X-10 System is based on power line communication. The
range of the Marmitek X-10 signals very much depends on the local
circumstances. On average the range is a cable length of 80 meters.
If you have difficulties with the range of your Marmitek X-10
signals, please pay attention to the following facts:
1. When more than one phase is used for your electrical system, it is
necessary to couple these phases for the Marmitek X-10 signals.
For coupling you can use FD10 Phase Couplers/Filters. You only need to
install a Phase Coupler/Filter when your wall outlets and light switches are
divided over more than one phase (more than one group is no problem).
For bigger buildings or longer distances we advice you to use an active
repeater instead of passive FD10’s.
2. It is possible that Marmitek X-10 signals are attenuated by devices and
lights which are connected to the power line. In a normal home situation
this effect is negligible (the Marmitek X-10 system is using active gain
control to eliminate the effects). However, it is possible that a particular
device in your house is attenuating the signals so much that the range of
Marmitek X-10 signals is decreased significantly. When you have range
problems, it is wise to try to locate the device which is attenuating the
4© MARMITEK