56
Operating instructions for Control 410
Installation and initial operation
4.7.5 Wireless remote control
If deadman mode has been activated, it is not possible to operate the door by
remote control.
A maximum of 28 wireless hand transmitters or wireless wall-mounted
transmitters can be used in conjunction with the roller shutter control unit.
Each of these transmitters must be programmed into the controls as follows.
If deadman mode has been activated, no transmitters can be
programmed in and, for safety reasons, the stored data for all
transmitters that have already been programmed will be deleted.
Programming hand transmitters (Step 5)
The programming process is carried out as shown in the following flow chart:
37
Product description
Operating instructions for Control 410
2.3 Features
The Control 410 roller shutter control unit can be used to operate tubular
drives with integrated travel cut-out systems and a power consumption of up
to 600 VA. The areas of application are privately and commercially used
garage doors and gateways. If used with roll-up grilles or other doors with
openings or penetrations, the controls may be operated only in deadman
mode (see Chapter 4.7.2)!
Drive commands can be given using the integrated direction buttons, an
externally connected key switch (if fitted), or a wireless hand transmitter.
The operating parameters are set via a menu system and 6 LEDs inside the
housing. Two of these LEDs are visible from the outside and indicate the most
important operational states.