English / Page 25
Legend:
Switches (system plugs):
S5 Wicket door switch
S6 Cable slack switch
S7 Night lock
Switches (screw terminals):
S5a * Wicket door switch
S6a * Cable slack switch
S6b ♦ Cable safety device
Plug connections:
X31 Closing edge safety device
(in control unit)
X71A Wicket door contact
X71B Cable slack switch
X71C Night lock
X71D Cable slack switch
X72 Optosensor receiver
X73 Connection cable
X74 Optosensor transmitter
Terminal blocks:
X2c Static current circuit
(in control unit)
X7C Coiled cable
X7H Static current circuit
X7L Cable slack switch
X7V ♦ Connection terminal
Optosensors:
V5 Transmitter
V6 Receiver
* If connected, the shortcircuit bridge
must be removed.
♦ If available
7. Connection of closing edge safety device
Function:
The closing edge safety device monitors the bottom door seal. If whilst closing
the door meets with an obstruction, the closing edge safety device automatically
halts the door and lifts it to clear the obstruction.
Fig. 8: Wiring diagram closing edge safety
device
Connecting the closing edge safety
device:
Insert the optosensors into the bottom
door seal and connect them according
to fig. 8.