11
3.5.2.3 Setting of end position DOOR OPEN
• Move the door manually into the mechanical end position DOOR OPEN.
• Loosen the locking device (grub screw J) of the switch cam (B).
• Adjust switch cam B so that the limit switch DOOR OPEN (G) is operated as shown in
illustration D.3 (position (H)).
• Fix the switch cam (B) again by tightening the grub screw (J).
• If necessary, adjust the door position DOOR OPEN with the screw for fine adjustment
(K) at the switch cam.
• Please mount the case lid afterwards.
Legend illustration D/1 - D/3:
A Cam end position DOOR CLOSED
B Cam end position DOOR OPEN
C Cam for soft running out DOOR CLOSED
D Cam for soft running out DOOR OPEN
E Cam SKS-Stop
F Free cam
G Limit switch
H Position of the respective cam
J Grub screw
K Screw for fine adjustment
3. Initial operation of the Control 22 / 23 control unit
ABCDEF
B
J
H
G
Fig. D/3: Setting of end position DOOR OPEN