G. Display functions and programming possibilities
Learning of drive power:
Attention!
If the operator cuts out during the test run and LED 8 and LED 2
are flashing quickly (error number 10 / automatic cut-out):
• Set the automatic cut-out
• For this look up point 2:
Programming 2nd level, point 2 + 3.
• Travel the operator (with door engaged) completely and without interruption
two times from door position 'DOOR CLOSED' to door position 'DOOR OPENED'
and vice versa.
During these two learning travels the operator determines the maximum push
and pull force which is required to move the door. After two further complete
door travels the operator is definitely ready for operation.
These settings remain unchanged even if power supply is interrupted, but they
can, nevertheless, if necessary, be changed as described before.
Test:
• Press button .
–> The door must open and travel to the 'door open' position, that has been
set by you.
• Press button .
–> The door must close and travel to the 'door closed' position, that has been
set by you.
• Shortly press the button on your hand transmitter.
-> The operator moves the door to 'OPEN' resp. 'CLOSE' direction.
• Press the button on your hand transmitter again during the operator run.
-> The operator must stop
The next push onto the button causes the operator to run in the opposite direction.
GB
English Page 61
G. Display functions and programming possibilities
1. Programming 'light time'
• Press button for more than 10 sec,
until LED 2 flashes quickly.
• Still hold programming button and
press simultaneously button or ,
until LED 5 flashes quickly and all others
are on.
• Release button .
The control unit changes to the
programming menu 'light time'.
LED1 flashes.
• With button or the light time can
be set in steps from 1 (90 sec.) to 16
(240 sec.) (according to table).
• Save your setting with programming
button .
The control unit changes automatically to
programming menu 'signal lights'.
Advice:
Still hold programming button , when after 2 sec. LED 2
starts to flash. To come to the programming menu of
extended operator functions, please hold programming
button for further 8 sec. (LED 2 then flashes quickly).