10 English
Device description
The maximum amount of equipment is described in
these operating instructions. Depending on the model
used, there are differences in the scope of delivery (see
packaging).
For the illustrations, refer to the graphics page
Illustration A
1Connection adapter with integrated check valve
2Sealing plug
3Connection G 1 (33.3mm) suction line (inlet)
4Filling nozzle with cap
5Connection G 1 (33.3mm) pressure line (outlet)
6Connection adapter for pumps G 1
7ON/OFF switch
8Pressure indicator
9Stand with elongated hole for screwing
10 Air valve (car valve) with cap
11 Power supply cable with plug
12 Drain screw
Startup
We recommend using only original Kärcher suction hos-
es, filter components and hose connections. Using
components from other manufacturers can lead to mal-
functions when sucking the feed fluid, especially when
using bayonet connection systems.
Before initial startup
Preparation
Before initial startup, check the pressure of the air
filling in the storage tank. If necessary, top up to 2.0
bar with a commercially available air pump when
switched off/depressurised.
Illustration B
Secure the device against slipping, screw it down if
necessary.
Remove the sealing plug.
Screw the connection adapter with integrated check
valve into the suction connection of the pump (inlet).
Illustration C
Note
If the water is dirty, we recommend fitting a pre-filter
(see Special accessories) between the check valve and
the suction hose.
Illustration D
1 Connect vacuum-proof suction hose with integrated
backflow stop to suction side. (Available as an spe-
cial accessory).
2 Screw the connection adapter into the pressure con-
nection of the pump (outlet).
3 Connect the pressure line.
4 Open the filling nozzle cap.
Illustration E
Fill with water until it overflows.
Illustration F
Screw the cap tightly onto the filling nozzle.
Open existing stop valves in the pressure line.
Note
Even minor leaks lead to malfunctions.
In case of leaks, seal all connections with a suitable
sealant (e.g. Teflon tape) to avoid malfunctions due
to leakage or air intake.
Permanent installation
In a permanent installation, the pump can be screwed to
a suitable surface.
Screw the pump tightly to a level surface using suit-
able screws.
In addition, in the case of a fixed installation, it is recom-
mended to fit a flexible component on the pressure side,
such as a flexible pressure equalization hose (see Spe-
cial accessories), on the pressure side. This has the fol-
lowing advantages:
Greater flexibility in erection and installation.
Sound reduction since no vibration is transmitted in
to the pipes of the house water system.
With smaller leaks, the pump switches less often.
Note
In order to simplify the subsequent draining and pres-
sure relief of the system, we recommend the installation
of a stop cock between the pump and the pressure line
(not included in the scope of delivery).
Closing the stop cock prevents water from flowing out of
the pressure line when the pump is drained.
Operation
Operation
1. Plug the mains plug into the socket.
2. Switch the device on with the ON/OFF switch.
Note
Pump starts immediately. Wait until the pump sucks in
and delivers evenly, then close the stop valves in the
pressure line.
After reaching the switch-off pressure, the pressure
switch switches off the motor. The storage tank is now
filled, the domestic water supply is ready for operation.
If there is no water supply, the switch-off pressure is not
reached and the pressure switch can no longer shut off
the device. This heats up the water in the pump head.
To prevent damage to the pump due to overheating, the
power supply is interrupted by the thermal switch in the
event of overheating. After cooling down, the power
supply is restored.
Note
The cooling time until the engine restarts can be up to
150 minutes.
We recommend the use of a dry-running protection de-
vice (see special accessories) for regular protection
against water shortage.
ATTENTION
Risk of injury, the system is pressurised!
When opening a pressurised system, you can be in-
jured by flying parts.
Depressurise the device before opening the connec-
tions (for pressure, see chapter Technical data)
Ending operation
1. Switch off the device at the ON/OFF switch.
2. Unplug the device at the mains plug.
Care and maintenance
DANGER
Danger of electric shock.
Always switch the device off and disconnect the mains
plug before working on the device.
The device is maintenance-free.
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Karcher BP 3.200 Home bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Karcher BP 3.200 Home in de taal/talen: Alle talen als bijlage per email.

De handleiding is 3.44 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info