The IMPRESSA is set to 16° dH by default. You can change this setting.
Proceed as follows:
Ⅲ READY
Ⅲ Press and hold the Rotary Switch (1) until RINSE appears on the dis-
play.
Ⅲ The illuminated ring (2) is active.
Ⅲ Turn the Rotary Switch (1) until the following message appears on
the display:
Ⅲ HARDNESS
Ⅲ Now press the Rotary Switch (1) to enter the programme item.
Ⅲ 16° dH
Ⅲ Now turn the Rotary Switch (1) until the desired water hardness
appears.
Ⅲ For example 20° dH.
Ⅲ Confirm the desired water hardness by pressing the Rotary Switch (1).
Ⅲ OK
Ⅲ HARDNESS
Ⅲ Turn the Rotary Switch (1) until the following message appears on
the display:
Ⅲ EXIT
Ⅲ Now press the Rotary Switch (1) to exit programming mode.
Ⅲ READY
5. Using the CLARIS filter cartridge
If you use the CLARIS filter cartridge correctly, your automatic
coffee machine no longer has to be descaled. The DE-SCALE
programme item no longer appears.
5.1 Inserting the filter
Ⅲ Press and hold the Rotary Switch (1) until RINSE appears on the dis-
play.
Ⅲ The illuminated ring (2) is active.
Ⅲ Turn the Rotary Switch (1) until the following message appears on
the display:
Ⅲ FILTER –
Ⅲ Press the Rotary Switch (1) again to enter this programme item.
Ⅲ NO –
Ⅲ Turn the Rotary Switch (1) until the following message appears on
the display:
Ⅲ YES ߛ
Ⅲ Press the Rotary Switch (1) to activate the filter cartridge.
Ⅲ OK
Ⅲ INSERT
OPEN TAP
Ⅲ Remove and empty the water tank (10).
Ⅲ Fold up the filter holder. Insert the filter cartridge in the water tank,
exerting slight pressure (Fig. 1).
Ⅲ Close the filter holder until it audibly snaps into place.
Ⅲ Fill the water tank with cold, fresh mains water and reinsert the
tank.
Ⅲ Place a sufficiently large receptacle (around 1 litre) under the Pro-
fessional Cappuccino Frother (15) (Fig. 10).
Ⅲ Open the steam / hot water draw-off tap (14) (Fig. 13).
Ⅲ FILTER
RINSING
E