555040
3
Verklein
Vergroot
Pagina terug
1/6
Pagina verder
GSM car alarm CA-1802 „Athos“ 3/6 MHF57202
Configuration table - be careful to put spaces between words in SMSes (e.g. MASTER RESET EN 1).
SIM entry* SMS instruction Text Description
RESET EN 1
(After which, the
entry is erased
from the SIM)
MASTER RESET EN 1 Mode setting. RESET 1 = alarm has its own remote control and provides signals for central
locking. Performing the RESET instruction is indicated by 4 beeps. Consequently, all settings, enrolled
remote controllers and wireless detectors will be erased.
Not applicable MASTER UC uuuu
User code setting – the code allows you to operate the alarm remotely via SMS from unauthorized
phones. uuuu is a new user code, 4 to 8 letters (A–Z & 0–9, case insensitive). Factory default user code
is USER
Not applicable MASTER MC xxxx Master code setting –xxxx is a new master code (A–Z & 0–9, case insensitive). The code allows you to
change the maintenance settings for the car alarm. Factory default master code is MASTER
TEL1 xx...x MASTER TEL1 xx...x
TEL2 xx...x MASTER TEL2 xx...x
TEL3 xx...x MASTER TEL3 xx...x
TEL4 xx...x MASTER TEL4 xx...x
Setting of phone numbers to report alarms to (these phones will also be authorized to control the
alarm via SMS without a user password)
E.g.: MASTER TEL2 +420602123456 will enter the phone number into memory TEL2
MASTER TEL3 0 will erase the memory TEL3.
DIAL1 xx...x
MASTER DIAL1 xx...x
DIAL2 xx...x
MASTER DIAL2 xx...x
DIALA xx...x
MASTER DIALA xx...x
DIALB xx...x
MASTER DIALB xx...x
Setting the phone numbers to dial using Hands free.
E.g.: MASTER DIAL2 +420602123456 will assign the number to the
button of the remote controller.
MASTER DIAL2 0 will erase the number assigned to the
button.
Not applicable MASTER LEARN RC Enrollment of RC-8x controllers - up to 4 controllers can be enrolled, turn the ignition key on before
sending the instruction. To enroll controllers, press and hold buttons
and together for 3 seconds.
After you have enrolled all remote controls, turn the ignition key off. By enrolling the first controller all other
controllers previously enrolled will be erased. All the desired controllers should be enrolled in a single enrollment
session.
Not applicable MASTER LEARN INT
(EXT)
JA-8X wireless detector enrollment – see the description in section 5. Up to 8 detectors can be
enrolled (the total of both groups). Turn the ignition key on before sending the instruction. To enroll the
sensors, insert their batteries. After you have enrolled all detectors, turn the ignition key off. All desired
detectors from a single group should be enrolled in a single enrollment session.
DIP abcdefghij MASTER DIP
abcdefghij
DIP parameter entry – see the DIP table
SET abcdefghij MASTER SET
abcdefghij
SET parameter entry – see the SET table
TELU xx...x MASTER TELU xx...x SIM card validity maintenance call setting (for pre-paid cards) 1x month the xx..x number is called, call
duration 10 s to maintain the validity of SIM cards requiring this.
Not applicable MASTER TXT 01,text
Modifying SMS messages and instructions (see chapter 9.1). The maximum length of a single text is 30
characters. Information texts (with indices starting at 27) can be modified using the user code USER (optional). To
change instruction texts (indexed by 01 to 26) the MASTER installation code is always necessary.
It is not possible to modify access codes or SMS texts to enroll controllers or detectors by storing numbers in the SIM card phone directory.
Always use CAPITAL letters when writing into the SIM card!!!
6. DIP parameters
Parameters A to J correspond to DIP switches. Setting is performed
by SMS: MASTER DIP ABCDEFGHIJ
Description
DIP
0 1
A 0 = silent arming/disarming without siren chirps
1 = 10 ms siren chirps when arming/disarming (non backed-up siren)
2, 3, 4 ... 9 = siren chirps when arming/disarming (a siren of another
type) lasting 20, 30, 40, 50, 100, 200, 300 or 500 ms
B Silent alarm
Audible alarm
C
SMS alarm report only
SMS alarm report and siren sound
phone call
D SMS remote control not
confirmed by SMS reply
SMS remote control instructions
confirmed by SMS reply
E
0 = arming control by dialling-in disabled
1 = arming control by dialling from TEL1 enabled
2 = arming control by dialling from TEL1 and TEL2 enabled
3 = arming control by dialling from TEL1, TEL2 and TEL3 enabled
4 = arming control by dialling from all TEL1 to TEL4 enabled
F
Arming control by dialling
in is not confirmed by
SMS
Arming control by dialling in (see E)
is confirmed by SMS to the phone
which called the car alarm
G
User can not change SMS
Texts
User can change SMS texts by TXT
Sequence
H
REARM disabled
If the car is not entered within 1
minute after disarming, it will REARM
I
0 = Immobilization by arming* and by SMS instruction**
1 = Immobilization by arming* and automatically 5 minutes after
ignition is turned off (AUTOIMO) and also by SMS instruction**
2 = Immobilization only by SMS instruction
3 = Immobilization and also by SMS instruction. If disarmed and
ignition is turned off for more than 60 minutes the SMS STATUS is
sent as an alert to possible forgotten arming.
J
Self-location disabled
The car’s location will be sent by
SMS after an IMO instruction has
been performed. or if the car stops
after an immobilization SMS
instruction (See 13.6.)
Factory default setting is DIP 1111000000 (bold letters in the text).
* When the car is armed, the immobilization circuit is inactive. To
activate the circuit after the car has been disarmed, it is necessary to
turn the ignition key on.
** This SMS instruction results in immobilization that can only be
cancelled via an appropriate SMS instruction. Arming or disarming the
car will not mobilize the car in this case.
7. SET parameters
Parameters A to J correspond to SET switches. Setting is performed
by SMS: MASTER SET ABCDEFGHIJ
Description
SET
0 1
A 0 = open door signalling and INP activation while arming are both
disabled
1 = open door signalling and INP activation while arming are
both enabled
2 = INP activation while arming enabled, open door signalling
enabled with a 10 second delay
3 = INP activation while arming enabled, open door signalling
disabled
B
Voltage detector disabled
Voltage-drop detector enabled
C
lock / unlock signal duration
0 = 0.5 / 0.5 sec (suitable for electromagnetic locks)
1 = 4 / 4 sec (suitable for pneumatic locks)
2 = 60 / 0.5 sec (suitable for automatic window closing)
D
DOOR input logic:
1 = activated by falling edge (grounding)
2 = activated by rising edge (disconnecting from GND)
E INP1 logic:
1 = activated by falling edge (grounding)
2 = activated by rising edge (disconnecting from GND)
F INP2 logic:
0 = activated by falling edge (grounding), it triggers an alarm also
if disarmed (24 hour reaction) 1 = activated by falling edge
(grounding)
2 = activated by rising edge (disconnecting from GND)
G no function in Mode1, you can enter 0
H no function in Mode1, you can enter 0
I no function in the CA-1802 version, you can enter 0
J 0 = AUX output is a bus for communication with CR-11A modules
1 = AUX output provides power for external sensors
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron CA-1802 - Athos GSM RESET 1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron CA-1802 - Athos GSM RESET 1 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,3 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Jablotron CA-1802 - Athos GSM RESET 1

Jablotron CA-1802 - Athos GSM RESET 1 Gebruiksaanwijzing - English - 16 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info