578941
2
Verklein
Vergroot
Pagina terug
1/4
Pagina verder
3. PUTTING INTO OPERATION
The communication between the main unit (receiver) and the remote sensor (transmitter)
is wireless, thus simplifying the installation. The remote temperature sensor transmits data
to the main unit, with an operating range of up to 100 feet (30 meters) in opened area.
The remote temperature sensor can be placed indoors or outdoors, depending on the area
where the temperature is intended to be measured. If you intend to measure outdoor
conditions, place the remote sensor outdoors.
Start-up the transmitter-receiver communication:
• It is important to power-up the remote sensor BEFORE powering-up the main unit.
Immediately after batteries are installed, the remote sensor will start transmitting a
temperature and humidity data to the main unit.
• It is strongly recommended to power up and test communication between the remote
sensor and the main unit BEFORE permanently mounting the sensor outside.
• During initial set up, place the remote sensor within a range of 1m to the main unit in the
same room, both receiver and transmitter far from any other electric product.
After reception is established (remote readings will appear on the main unit’s display),
position the remote sensor and the main unit within the maximum transmission range of
up to 30 meters (100 feet).
NOTE:
Avoid pressing any button on the main unit before the remote readings are displayed.
• Transmission or reception range may be affected by trees, metal structures, electronic
appliances, surrounding building materials and how the main unit and transmitter are
positioned.
Placement of sensor and main unit
• Place the remote sensor so that it faces the main unit (receiver), minimizing obstructions
such as doors, walls and furniture.
• Though the remote sensors are weather-resistant, they should be placed away from direct
sunlight, rain or snow. The optimal location for the outdoor sensor is under the eaves on
the north side of a building with free air circulation.
• The remote sensor can be placed on the flat surface or mounted on the wall in vertical
position by using the included stand. For fixing the stand, use a screw, rather than a nail.
• Ideally, place the remote sensor over soil, rather than asphalt which may affect the
correct measurement.
Avoid placing the remote sensor near sources of heat, such as chimneys and heating
elements
Avoid areas that collect heat from the sun and radiate heat, such as metal, brick or
concrete structures, paving, and patios
• The international standard for the valid air temperature measurements is 1.25meters
(4 feet) above the ground
• When mounting the main unit on the wall or vertical surface, fold the table stand back
into the unit.
• Make sure that the main unit is locating within the operating range of all remote sensors.
• Ideally the main unit should be placed within line of sight of remote sensors. Avoid
placing the main unit where surfaces emitting and radiating heat (e.g. heating ducts or air
conditioners) and areas with interference from wireless devices (e.g. cordless phones,
radio headsets, baby monitoring devices and other electronics).
Important notice about batteries
• The HBR636 is delivered with batteries to make the start-up easy for you. These
batteries may not last as long as fully new batteries may. Once you have to replace the
batteries on the outside sensor, we recommend to use alkaline batteries. Advantage of
this is a better performance in case the outside temperature falls below 0° (32°F). For
optimum performance, we recommend even lithium batteries.
Avoid using rechargeable batteries. (Rechargeable batteries cannot maintain correct
power requirements.)
ALWAYS install batteries in the remote sensor before the main unit.
• Insert batteries before first use, matching the polarity in the battery compartment.
When the
display
shows...
Forecast
is...
Sunny
Partly
Cloudy
Heavy
Rainy
Heavy
Snowy
Cloudy Rainy Snowy
NOTE: The weather forecast accuracy is approximately 70%. The HBR636 shows
the forecasted (predicted), not the current conditions. The SUNNY icon indicates
clear weather, even when displayed during the night-time.
4.1.1 OPERATION OF THE WEATHER/PRESSURE WINDOW
For all operations described in Chapter 4.2, press UP () or DOWN () until the
pressure icon “PRESSURE”, to the left of the barometric pressure value, begins to
flash.
The pressure window displays the weather forecast and the local barometric or sea level
pressure. Additionally you may see some statistical data like the pressure reading and
bar-chart for the past 24 hours or a temperature or humidity history bar chart.
Pressure can be displayed in hPa/mBar, inHg or mmHg, and altitude is set in meters or feet.
There are three viewing options available: barometric pressure SEA LEVEL or LOCAL
or ALTITUDE. Local pressure is a measured value (can’t be adjusted) while the
SEA LEVEL is calculated from the Altitude setting. You may also set the SEA LEVEL
value directly, but it is advisable to program only the Altitude and allow the unit to
calculate the SEA LEVEL value. The direct setting of the SEA LEVEL is only advised
if you wish to calibrate the SEA LEVEL pressure based on very accurate pressure
information for your location.
The unit is designed to measure the pressure changes at your specific location and show
this value as the LOCAL barometric pressure.
The SEA LEVEL pressure value is meant to match your local meteo information (like on
TV, radio, newspaper etc.).
4.1.2 SETTING INITIAL PRESSURE PARAMETERS
NOTE: The unit will automatically exit any programming mode if it does not detect a
button press for about 1 minute.
SELECT PRESSURE AND ALTITUDE UNITS
Select the PRESSURE window.
Press MODE button, to toggle through selections until “SEA LEVEL” or “LOCAL”
barometric pressure is displayed.
Press and hold MEM button to enter the setting of the pressure unit (unit blinking). Press
the UP () or DOWN () button to select the preferred barometric pressure unit:
hPa/mBar, inHG or mmHg (hPA is the international standard: 1hPA = 1 mBar.). Press
MEM to confirm your selection.
Then press MODE to move to the Altitude unit selection mode. Press and hold MEM
button to enter select the altitude unit (unit blinking). Press the UP () or DOWN ()
button to select FEET or METER. Press MEM to confirm.
PROGRAMMING ALTITUDE
Select the PRESSURE window.
Press MODE to move to the
Altitude setting.
Press and hold MODE to move to the ALTITUDE value setting (altitude value blinking).
Press UP () or DOWN () to adjust the altitude value to your location. (Press and hold
either button for fast adjustment)
Press MODE to confirm the programming selection.
PROGRAMMING SEA LEVEL PRESSURE (not required if you did altitude)
Select the PRESSURE window.
Press MODE, to toggle through selections until “SEA LEVEL” is displayed.
Press and hold MODE, until the barometric pressure digits are flashing.
Enter the desired sea level pressure value by pressing UP () or DOWN () buttons.
(Press and hold either button for fast adjustment).)
Press MODE, to confirm sea level value selection.
VIEWING PRESSURE AND ALTITUDE INFORMATION
Select the PRESSURE window.
Press MODE. With each press, the display will alternate between the sea level pressure,
local pressure and the local altitude.
VIEWING SEA LEVEL PRESSURE HISTORY
Select the PRESSURE window.
Press MEM to enter the sea level pressure display.
When the SEA LEVEL is displayed, press MEM repeatedly viewing the sea level
pressure history for the past 24 hours in 1 hour intervals.
If no buttons are pressed for 5 seconds, the unit will automatically return to the default
Pressure and Weather Forecast Mode.
VIEWING PRESSURE, TEMPERATURE AND HUMIDITY CHARTS
The bar chart in Pressure Window can be configured to display a historical data for the
sea level pressure and temperature or humidity for channel 1 (only channel 1!).
After selecting the Pressure Window, press and hold ALARM button to toggle the bar
chart between the sea level pressure with a word “PRESSURE” displayed at the right
bottom corner of the chart, temperature with a thermometer icon and “CH1” and a
humidity with “RH” icon and “CH1”.
4.1.3 MOON PHASE
In steps of 3 days, the current moon phase is displayed by the following icons (the dark
part is same as with the moon: dark !)
New
Moon
Waning
Crescent
First
Quarter
Waxing
Gibbous
Full
Moon
Waning
Gibbous
Last
Quarter
Waning
Crescent
4.2 TEMPERATURE/ HUMIDITY WINDOW
The main unit supports up to 3 remote sensors, each corresponding to a separate channel
of the temperature and relative humidity display. The temperature can be displayed in
Celsius (ºC) or Fahrenheit (ºF).
The main unit carries the "indoor" temperature and humidity sensor and uses this data to
calculate the indoor comfort level - Wet, Comfort, Dry or "NO INDICATION".
A temperature alert function is available for all channels. It can be programmed to sound
once one of the remote temperatures exceeds or falls below the pre-set upper and lower
limits.
OPERATION OF THE TEMPERATURE/HUMIDITY WINDOW
FORCED SEARCH FOR REMOTE SENSORS
Select the TEMPERATURE/HUMIDITY window.
The main unit can be manually activated to search for the signal from the selected remote
sensor by pressing and holding the DOWN () button.
The wave icon above the current channel icon shows the connection status of the
corresponding remote sensor:
For all operations described in Chapter 4.4, press UP () or DOWN () until the
icon, to the left of the indoor temperature value, begins to flash.
Icon
Status
Searching for the signals from the remote sensor
Corresponding remote sensor signal received
successfully
No signals received for over 1 hour
VIEWING REMOTE (CHANNEL) TEMPERATURE AND HUMIDITY
Select the TEMPERATURE/HUMIDITY window.
Static Display: Press the CHANNEL button to select measurements from different
remote sensors (channel 1, 2 or 3).
Channel Auto-Scan Display: To enable an automatic scan of all present channels, press
and hold CHANNEL, until the icon is displayed. The measurements from each
remote channel will be alternately displayed with a 5 seconds viewing.
NOTE: the channel auto-scan feature can be active only if there are more than one
remote sensors operating and are MODE to different channels.
PROGRAMMING TEMPERATURE IN CELSIUS OR FAHRENHEIT
Select the TEMPERATURE/HUMIDITY window.
Press and hold MODE button for 3 seconds to toggle the temperature unit in Celsius (ºC)
or Fahrenheit (ºF).
TEMPERATURE ALARM
Select the TEMPERATURE/HUMIDITY window.
Press ALARM button selecting the desired alarm, the upper temperature alert with icon
(if disabled, display shows OFF), or lower temperature alert with icon (if disabled,
display shows OFF).
Press and hold ALARM button until the temperature digits flashing. Adjust the
temperature digits using the UP () or DOWN (). Press and hold either button for fast
setting. Press the ALARM to confirm selection and return to the temperature alarm
selection screen
ACTIVATING OR DEACTIVATING TEMPERATURE ALARMS:
Once the above alerts are displayed, press the UP () to enable or DOWN () to disable
the alert.
VIEWING MAX/MIN READINGS
Select the TEMPERATURE/HUMIDITY window.
Press the MEM button to read the minimum temperature and humidity of all sensors
(indoor and remote) with the MIN, next MEM press the maximum values with the MAX
icon and then back to the current values.
4. OPERATION
Immediately after batteries are installed, the remote sensor will start transmitting the
temperature and humidity data to the main unit in regular intervals.
Once the main unit is powered-up by activating the batteries, the display will show all
available LCD segments for a moment.
IMPORTANT: After this, all of the display functions will be locked for about 1 minute
(or as long as you are performing a setting), allowing setting your local altitude and
pressure parameters by pressing the UP () or DOWN () and MODE buttons. The
locked display will show the pressure icon and abbreviation “hPA/mBar” flashing in the
Weather/ Pressure Window,
If pressure and altitude are not set within this minute, the unit will self-calibrate and show
the default settings for the pressure and altitude (sea level).After this, the unit will scan the
remote sensors (Ch 1 to Ch 3) in the Temperature/ Humidity Window. There is no
immediate need to press any button during this process.
After this, the unit will start to scan the DCF77 time transmitter in the Clock Window.
Thereby, the default time the unit has started with at the beginning is 12:00. Here too,
there is no immediate need to press any button during this process.
Recommendation: Allow the unit to receive the sensors and the time without touching
ANY button for about 6-8 minutes during the main unit initial set up. This will give the
unit time to synchronize with remotes, stabilize pressure readings and settle with default
settings.
4.1 WEATHER FORECAST
This unit is capable of detecting the atmospheric pressure changes. Based on collected
weather data, it forecasts the weather for the next 12 to 24 hours.
3938
4140
4342
4544
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Irox HBR636 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Irox HBR636 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,49 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Irox HBR636

Irox HBR636 Gebruiksaanwijzing - Deutsch - 4 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info