18
6
SCAN OPERATION
■ Skip channel setting
Memory channels can be set to be skipped for memory skip
scan. In addition, memory channels can be set to be skipped
for both memory skip scan and frequency skip scan. These
are useful to speedup the scan interval.
q Select memory mode with [V/M].
w Rotate [DIAL] to select memory channel to be pro-
grammed as a skip channel.
e Push [V/M] for 2 sec. to enter expanded set mode.
r Rotate [DIAL] until “SKIP” appears.
•Turn the expanded set mode ON for selection. (p. 28)
•“SKIP” disappears after 1 sec. and “Sk” appears.
t While pushing [FUNC], rotate [DIAL] to select condition.
•“OFF” for no skipping of channels, “SKIP” for memory skip scan
or “P SKIP” for frequency skip scan and memory skip scan.
y Push [V/M] to exit set mode.
This setting is effective when the frequency skip function
(P SCAN) is turned ON. See the next page for details.
■ Scan resume condition
DSetting the scan pause time
The scan pauses when receiving signals according to the
scan pause time. It can be selected as a pause or timer scan.
q Push [V/M] for 2 sec. to enter expanded set mode.
w Rotate [DIAL] until “PAUSE” appears.
•Turn the expanded set mode ON for selection. (p. 28)
e While pushing [FUNC], rotate [DIAL] to select condition.
•“2SEC”–“20SEC”: scan pauses for 2–20 sec. on a received sig-
nal.
•“HOLD”: scan pauses on a received signal until it disappears.
r Push [V/M] to exit set mode.
DSetting the scan resume time
The scan restarts after a signal disappears according to the
resume time. It can be selected to 0–5 sec.
q Push [V/M] for 2 sec. to enter expanded set mode.
w Rotate [DIAL] until “RESUME” appears.
•Turn the expanded set mode ON for selection. (p. 28)
e While pushing [FUNC], rotate [DIAL] to select condition.
•“1SEC”–“5SEC”: scan restarts 1–5 sec. after the signal disap-
pears.
•“0SEC”: scan restarts immediately after the signal disappears.