12124
44
Verklein
Vergroot
Pagina terug
1/48
Pagina verder
i400PRO
UHF TRANSCEIVER
INSTRUCTION MANUAL
IC-400PRO.qxd 03.6.19 6:13 PM Page a (1,1)
i
RWARNING! NEVER connect the transceiver to an
AC outlet. This may pose a fire hazard or result in an electric
shock.
RWARNING! NEVER operate the transceiver while
driving a vehicle. Safe driving requires your full attention—
anything less may result in an accident.
NEVER connect the transceiver to a power source of more
than 16 V DC. This will damage the transceiver.
NEVER cut the DC power cable between the DC plug and
fuse holder. If an incorrect connection is made after cutting,
the transceiver might be damaged.
NEVER place the transceiver where normal operation of
the vehicle may be hindered or where it could cause bodily
injury.
NEVER allow children to play with any radio equipment
containing a transmitter.
NEVER expose the transceiver to rain, snow or any liquids.
The transceiver may be damaged.
NEVER operate or touch the transceiver with wet hands.
This may result in an electric shock or damage the transceiv-
er.
PRECAUTION
Icom, Icom Inc. and the logo are registered trademarks of Icom
Incorporated (Japan) in the United states, the United Kingdom, Germany,
France, Spain, Russia and/or other countries.
SmarTrunk II™ is a trademark of the SmarTrunk Systems, Inc.
IMPORTANT
EXPLICIT DEFINITIONS
WORD DEFINITION
RWARNING
Personal injury, fire hazard or electric shock
may occur.
CAUTION
Equipment damage may occur.
NOTE
If disregarded, inconvenience only. No risk
of personal injury, fire or electric shock.
READ ALL INSTRUCTIONS carefully and com-
pletely before using the transceiver.
SAVE THIS INSTRUCTION MANUAL This
instruction manual contains important operating instructions
for the IC-400PRO UHF TRANSCEIVER.
IC-400PRO.qxd 03.6.19 6:13 PM Page i (1,1)
ii
DO NOT push the PTT when not actually desiring to trans-
mit.
DO NOT use or place the transceiver in areas with tem-
peratures below –10°C or above +60°C, or in areas subject to
direct sunlight, such as the dashboard.
AVOID operating the transceiver without running the vehi-
cle’s engine. When the transceiver’s power is ON and your
vehicle’s engine is OFF, the vehicle’s battery will soon
become exhausted.
AVOID placing the transceiver in excessively dusty envi-
ronments.
AVOID placing the transceiver against walls. This will
obstruct heat dissipation.
AVOID setting the transceiver in a place without adequate
ventilation. Heat dissipation may be affected, and the trans-
ceiver may be damaged.
AVOID the use of chemical agents such as benzine or
alcohol when cleaning, as they damage the transceiver sur-
faces.
USE the specified microphone only (supplied or optional).
Other microphones have different pin assignments and may
damage the transceiver.
BE CAREFUL! The transceiver will become hot when
operating continuously for long periods.
This device complies with Standard
Australia Specification No. AS/NZS4365-
1996 and AS4295-1995.
IC-400PRO.qxd 03.6.19 6:13 PM Page ii (1,1)
iii
TABLE OF CONTENTS
IMPORTANT ........................................................................ i
EXPLICIT DEFINITIONS ..................................................... i
PRECAUTION ..................................................................... i
TABLE OF CONTENTS ...................................................... iii
SUPPLIED ACCESSORIES ............................................... iv
1 PANEL DESCRIPTION ............................................... 1–4
Front panel ................................................................... 1
Function display ........................................................... 4
2 BASIC OPERATION .................................................... 5–6
Turning power ON ........................................................ 5
Channel selection ......................................................... 5
Receiving and transmitting ........................................... 6
3 REPEATER OPERATION ............................................... 7
Repeater operation.........................................................7
Accessing a repeater......................................................7
4 SCAN OPERATION ................................................... 8–14
Scan types......................................................................8
Scanning preparation .....................................................9
Open scan ....................................................................11
Group and priority scans ..............................................12
Repeater search scan ..................................................13
5 GROUP MODE OPERATION .................................. 15–16
Group mode (CTCSS)..................................................15
6 SELCALL OPERATION .......................................... 17–21
General.........................................................................17
Calling operation ..........................................................17
When receiving a call ...................................................20
Setting the silent stand-by condition.............................21
7 OTHER FUNCTIONS .............................................. 22–33
Smart-Ring and ATS
(Automatic Transponder System) .....22
Voice scrambler function ..............................................23
DTMF transmission ......................................................24
Channel lock function ...................................................24
RX frequency setting ....................................................25
Wide/Narrow function ...................................................26
Set mode ......................................................................27
8 PROGRAMMABLE FUNCTION KEYS ................... 34–36
9 CONNECTION AND MAINTENANCE .................... 37–40
Rear panel and connection ........................................ 37
Mounting the transceiver ............................................. 38
Optional UT-108 installation ....................................... 39
Optional UT-109 or UT-110 installation ...................... 39
Optional OPC-617 installation ..................................... 40
Antenna ....................................................................... 40
Fuse replacement ....................................................... 40
Cleaning ..................................................................... 40
10 SPECIFICATIONS ....................................................... 41
11 OPTIONS ..................................................................... 42
IC-400PRO.qxd 03.6.19 6:13 PM Page iii (1,1)
iv
q Microphone .................................................................. 1
w Microphone hanger and screw set .......................... 1 set
e Microphone hanger cable .............................................. 1
r DC power cable (OPC-1194) ..........................................1
t Function name stickers* (KEY STICKER) ......................1
y Mounting bracket ........................................................... 1
u Bracket bolts ................................................................. 4
i Mounting screws (M5×12) ............................................. 4
o Self-tapping screws (M5×20) ......................................... 4
!0 Flat washers .................................................................. 4
!1 Spring washers ............................................................. 4
!2 Nuts ............................................................................... 4
*Function name stickers
Function of keys can be changed. Stickers are supplied for
easy identification.
qw
e
ry
u
i
o
!0
!1
!2
t
KEY-STICKER
ICOM
SUPPLIED ACCESSORIES
IC-400PRO.qxd 03.6.19 6:13 PM Page iv (1,1)
1
1
PANEL DESCRIPTION
ie
q
Function Display (p. 4)
w
u y t r
Speaker
Front panel
q AF VOLUME CONTROL KNOB
Rotate the knob to adjust the audio output level.
Minimum audio level is pre-programmed.
w []/[ ] KEYS*
Push to select an operating channel.
After pushing [
O
], push to toggle between CB bank and
Private bank (user programmable channels).
e POWER SWITCH [ ]
Push to turn the power ON and OFF.
The Automatic scan start function and the password prompt are
available at power ON as optional settings. (The optional CS-
400PRO
CLONING SOFTWARE
is required.)
r [O] KEY*
Push to enter channel bank selection mode.
In channel bank selection mode, push []/[]to select the
desired channel bank.
Push for 1 sec. to toggle Function mode, Set mode or
Normal mode.
Returns to the Normal mode automatically after 30 sec. when
no key operations are performed in Function or Set mode.
Normal mode
Set mode Function mode
Push [
O
]
for 1 sec.
IC-400PRO.qxd 03.6.19 6:13 PM Page 1 (1,1)
2
1
PANEL DESCRIPTION
1
t [DUP] KEY*
NN
NN
Push to toggle the transmit frequency mode between
duplex and simplex. (CB channel 1 to 8 only)
Duplex: The set TX frequency is used for the transmission.
Simplex: The set RX frequency is used for the transmis-
sion.
NN
NN
Push and hold to set the selected channel to priority
or normal.
Priority channel is used for both group and priority scans.
FF
FF
Push to toggle the 5tone mute activity between CONT
(Continuous Tone) and SGL (Single Tone).
CONT: SelCall mute is released.
SGL: SelCall mute is activated. In this case, [PTT] switch
action is inhibited while SelCall mute is activated.
y [SCN] KEY*
NN
NN
Push to start or stop the scan.
NN
NN
Push and hold to enter the scan type selection mode.
Push []/[]to select the desired scan type.
Push [SCN] to set the channel as a tag channel.
-
S
appears for tag channels.
FF
FF
Push to recall the received ID code.
Push []/[]to select the record.
u [MONI] KEY*
NN
NN
Activates the following functions on each channel
independently:
Push and hold the key to release the mute to the channel
(audio is emitted; Audible condition).
- “” appears.
During “” appears, push the key to mute the channel
(sets to Inaudible).
NOTE: The unmute condition (Audiblecondition)
may automatically return to the mute condition
(Inaudiblecondition) after a specied time period
depending on the pre-setting.
FF
FF
Push to transmit the SelCall code on the selected
channel.
FF
FF
Push and hold to enter the SelCall code/code number
selection mode (p. 17).
Push []/[]to select the desired code/code number.
*Information
Up to two desired functions, one each for Normal and
Function mode, can be re-assigned to [], [], [
O
],
[DUP], [SCN] and [MONI] keys with the optional CS-
400PRO
CLONING SOFTWARE
. (p. 34)
The default setting is used in this instruction manual, for
description.
NN
NN
: Stands for Normal mode operation.
FF
FF
: Stands for Function mode operation.
IC-400PRO.qxd 03.6.19 6:13 PM Page 2 (1,1)
3
1
PANEL DESCRIPTION
Key flow chart for the default setting
i MICROPHONE CONNECTOR
Connect the supplied microphone or optional DTMF micro-
phone.
NEVER connect non-specified microphones. The pin
assignments may be different and the transceiver may
be damaged.
DD
MICROPHONE
The supplied microphone has a PTT switch and a hanger
hook.
The following functions are available when the microphone is on or
off hook:
(The optional CS-400PRO
CLONING SOFTWARE
is required.)
- Automatic scan start when on hook.
- Automatic priority channel selection when off hook.
- Sets to Inaudible condition (mute condition) when on hook.
- Sets to Audible condition (unmute condition) when off hook.
Normal mode
Function mode
Set mode
: Set the desired level/mode.
: Change the individual setting.
/
: Change the common setting.
: Push to enter channel bank selection mode.
Push for 1 sec. to enter Normal mode.
: Turn the function ON and OFF.
: [CH Up] : [ID-MR Select]
: [Bank/Func]
: [CONT/SGL]
: [Call]
: [CH Down]
: [CH Up] : [Scan Start/Stop]
: [Bank/Func]
: [Dup/Pri]
: [Moni(Audi)]
: [CH Down]
Push [
O
] for 1 sec.
Push [
O
] for 1 sec.
Push [ ] to turn power ON.
IC-400PRO.qxd 03.6.19 6:13 PM Page 3 (1,1)
4
1
PANEL DESCRIPTION
1
Function display
q TRANSMIT INDICATOR
Appears while transmitting.
w BUSY INDICATOR
Appears while receiving a signal or when the squelch is
open.
e SIGNAL STRENGTH METER
Indicates relative receive signal strength level.
r LOW POWER INDICATOR
Appears when low output power is selected.
[High/Low] must be assigned to the desired program-
mable key using the optional CS-400PRO
CLONING
SOFTWARE
when change the output power.
t SQUELCH INDICATOR
Appears when the channel is in Audible condition
(SelCall/CTCSS mute is released).
y DUPLEX INDICATOR
Appears when the duplex operation is selected.
u SCRAMBLER INDICATOR
Appears when the scrambler function is activated. (Optional
UT-109 (#02)/UT-110 (#02) SCRAMBLER UNIT is required.)
i SELCALL/5TONE INDICATOR
Appears when the specied Selcall/5-tone is received.
o SCAN CHANNEL INDICATOR
Appears when the selected memory channel is specied
as a scan channel.
!0 ALPHANUMERIC DISPLAY
Displays the operating channel number, channel names,
Set mode contents, DTMF numbers, etc.
!1 UNDER BAR INDICATOR
Shows the channel mute condition (Inaudiblecondi-
tion) as below.
The left under bar blinks in Function mode, and lights in
Set mode.
Appears in Set mode when the key under the indicator
can be activated.
During “” appears, the channel is
Audiblecondition
even if the channel is in mute condition.
The channel is in CTCSS mute condition.
The channel is in SelCall mute condition.
The channel is in both CTCSS/SelCall mute
condition.
t
q
w
e
r
u
i
!0
oy
!1
IC-400PRO.qxd 03.6.19 6:13 PM Page 4 (1,1)
5
2
BASIC OPERATION
Turning power ON
Push [ ] to turn the power ON.
Channel selection
Push []/[]to select the desired operating channel.
While pushing and holding []or [], the displayed channel
changes continuously until channel number 01 appears.
When displayed channel stops at channel number 01, beeps
are emitted.
D Private channel selection
q Push [
O
] (Bank/Func) to enter the channel bank selection
mode. Then select the desired bank with []/[]. Push
[
O
] (Bank/Func) again to set the bank.
w Push []/[]to select the desired operating channel in
sequence.
NOTE: The selected channel is retained even when the
transceiver is turned off.
Push [
O
]
Push [] or []
Push []
About the password prompt:
If the transceiver is programmed for a start up passcode,
enter the specied 4-digit code.
(The optional CS-400PRO
CLONING SOFTWARE
is required.)
The keys in the table below can be used for password input:
The transceiver detects numbers in the same block as identical.
Therefore 01234 and 56789 are the same.
When the PASSWORD indication does not clear after
entering 4 digit code, the enter code number is incorrect. In
this case, turn the power off and start over.
KEY
NUMBER
01234
56789
IC-400PRO.qxd 03.6.19 6:13 PM Page 5 (1,1)
6
2
BASIC OPERATION
2
Receiving and transmitting
RECEIVING:
q Push [ ] to turn the power ON.
w Select the desired operating channel. (p. 5)
e While receiving a signal, adjust the audio output level to a
comfortable listening level.
TRANSMITTING:
q While pushing and holding [PTT], speak into the micro-
phone at your normal voice level.
w Release [PTT] to receive.
IMPORTANT!: To maximize the readability of your signal;
After pushing [PTT], pause briey.
Hold the microphone 2 to 5 cm from your mouth, then
speak into the microphone at a normal voice level.
D Transmitting notes
Time-out timer
After continuous transmission for a pre-programmed period,
the time-out timer is activated causing the transceiver to stop
transmitting and automatically select receive.
NOTE: Transmission is inhibited when the channel is in 5
tone mute condition (Inaudiblecondition), or receive only
channel is selected.
IC-400PRO.qxd 03.6.19 6:13 PM Page 6 (1,1)
7
3
REPEATER OPERATION
Repeater operation
Repeaters allow you to extend the operational range of your
radio.
Normally, a repeater has independent frequencies for receive
and transmit.
Accessing a repeater
A repeater amplies received signals and re-transmits them
on a different channel, allowing you to communicate over
greater distances with improved reliability. When using a
repeater, the transmit channel is shifted from the receive
channel by 30 channels. You can search the accessible
repeater in your local area using the Repeater search scan
function (p. 13).
q Push []/[]to select the desired channel from 1 to 8
(repeater output channel).
w Push [DUP] (Dup/Pri) to set duplex.
“” appears.
The duplex setting is only available on channels 1 to 8.
e While pushing and holding [PTT], speak into the micro-
phone at your normal voice level.
The displayed channel automatically changes to the transmit
channel (repeater input channel), and “” appears.
r Release [PTT] to receive.
t To cancel the duplex setting, push [DUP] (Dup/Pri).
Repeater example;
Receives the channel 31 signal and
the detected audio signals are trans-
mitted on channel 1 simultaneously.
Station A:
Tx: Channel 31
Rx: Channel 1
Station B:
Tx: Channel 31
Rx: Channel 1
Ch 31 Ch 1
Ch 1 Ch 31
IC-400PRO.qxd 03.6.19 6:13 PM Page 7 (1,1)
8
4
SCAN OPERATION
3
4
Repeatedly scans all tag channels in sequence.
ch 40
ch 1 ch 2 ch 3
ch 4
ch 5
ch 6ch 39
OPEN SCAN
Repeatedly watches a priority channel while scanning
only specified tag channels.
ch 8
ch 26ch 12
Priority
channel
GROUP OR PRIORITY
SCAN
ch 1
RX only
ch 2
RX only
ch 8
RX only
TX on ch 31
RX on ch 1
TX on ch 38
RX on ch 8
TX on ch 32
RX on ch 2
TX on ch 33
RX on ch 3
TX on ch 34
RX on ch 4
Scan cancel
REPEATER SEARCH SCAN
Scans all repeater channels (1 to 8) in sequence.
If there are no busy channels after scanning channels 1
to 8 (RX only), it begins scanning from channel 1 again,
then the transceiver transmits a signal to search for a re-
peater while the scanning.
Scan types
The transceiver has 4 scan types, tag function and 4 resume
conditions providing scanning versatility.
Tag channels are independently set for open, group and pri-
ority scans. Initially, all channels may be set as tag channels
for all scans.
IMPORTANT!:
A microphone should be on hook to start scanning.
IC-400PRO.qxd 03.6.19 6:13 PM Page 8 (1,1)
9
4
SCAN OPERATION
Scanning preparation
IC-400PRO scans all tagged channels, and can be selected
so the scan resume condition is a pause or timer scan.
Therefore, these items must be set before starting a scan
(except the repeater search scan). These items must be set
for each scan type (open, group and priority) independently.
D Setting scan tag
q Select the desired channel. (p. 5)
w Push [SCN] (Scan Start/Stop) for 1 sec. to enter the scan
type selection mode.
e Push []/[]to select the desired scan type.
Open, group, priority and repeater search scans are available.
r Push [SCN] (Scan Start/Stop) to select the tag setting ON
and OFF.
S
appears when the tag setting ON (The channel is set as a
scan channel).
t Push [SCN] (Scan Start/Stop) for 1 sec. to return to
Normal mode.
To speed up scanning:
For open scan, cancel the tag channel setting to skip unde-
sired channels such as usually busy channels.
For group scan, set only often-used channels as tag chan-
nels.
All memory channels may be set as tag channels by
default.
Open scan setting
Push [SCN]
(Scan Start/Stop)
Appears for
the channels
to be scanned
Open scan
Push [] or []
Push [SCN] for 1 sec.
Previously selected scan type
is displayed.
IC-400PRO.qxd 03.6.19 6:13 PM Page 9 (1,1)
10
4
SCAN OPERATION
4
D Setting scan resume condition
q Push [
O
]
(Bank/Func)
for 1 sec. to enter Function mode.
w Push [
O
]
(Bank/Func)
for 1 sec. again to enter Set mode.
e Push [SCN] for 1 sec. to enter the common setting for the
transceiver.
r Push [SCN] several times until SST appears.
t Push []/[]to select the desired scan resume condi-
tion.
- T-5 : Scan pauses for 5 sec. then resumes.
- T-10 : Scan pauses for 10 sec. then resumes.
- T-15 : Scan pauses for 15 sec. then resumes.
- P-5 : Scan pauses until the signal disappears, then resumes
5 sec. after the signal disappears.
y Push [SCN] for 1 sec., then push [
O
] for 1 sec. to return to
Normal mode.
T-5 setting
T-10 setting
P-5 setting
T-15 setting
SST appears
Push [SCN]
Channel*Bank*
The keys under these indicators can be activated.
*The bank and channel number
are continuously displayed af-
ter entering set mode.
Push [
O
] for 1 sec.
[
IC-400PRO.qxd 03.6.19 6:13 PM Page 10 (1,1)
11
4
SCAN OPERATION
Open scan
Open scan searches for being transmitted signals automati-
cally and makes it easier to locate new stations for contact or
listening purposes.
IMPORTANT!:
A microphone should be on hook to start scanning.
During open scan, transmission is inhibited except on a
busy channel.
q Push [SCN] (Scan Start/Stop) for 1 sec. to enter the scan
type selection mode.
w Push []/[]to select the open scan.
e Push [SCN] (Scan Start/Stop) for 1 sec. to return to
Normal mode.
- OS appears besides the channel number indication.
r Push [SCN] (Scan Start/Stop) to start the open scan.
t When receiving a signal, scan pauses and resumes
according to the selected scan resume condition. (p. 10)
y Push [SCN] (Scan Start/Stop) to cancel the scan.
Start channel
Open scan setting
Open scan
Push [] or []
Push [SCN] for 1 sec.
Previously selected scan type
is displayed.
IC-400PRO.qxd 03.6.19 6:13 PM Page 11 (1,1)
12
4
SCAN OPERATION
4
Group and priority scans
Group and priority scans repeatedly watch a priority channel
while scanning specied channels. This is useful when wait-
ing for a call on the priority channel or several specied chan-
nels.
Group and priority scans behave differently when transmit-
ting. Group scan can only transmit on a busy channel, and
priority scan can only transmit on a priority channel or start
channel.
IMPORTANT!:
A microphone should be on hook to start scanning.
q Push [SCN] (Scan Start/Stop) for 1 sec. to enter the scan
type selection mode.
w Push []/[]to select the group or priority scan.
e Push [SCN] (Scan Start/Stop) for 1 sec. to return to
Normal mode.
- GS or PS appears besides the channel number indication.
r Select the priority channel if desired.
- Push []/[]to select the desired channel.
- Push [DUP] (Dup/Pri) for 1 sec. to set the channel as a priority
channel.
t Push [SCN] (Scan Start/Stop) to start the scan.
y When receiving a signal, the scan pauses and resumes
according to the selected scan resume condition. (p. 10)
u Push [SCN] (Scan Start/Stop) to cancel the scan.
Group scan Priority scan
Start channel
Group scan setting Priority scan setting
Priority channel
Group scan
Priority scan
Push [] or []
IC-400PRO.qxd 03.6.19 6:13 PM Page 12 (1,1)
13
4
SCAN OPERATION
Repeater search scan
The repeater search scan is not only searching for a signal
on the repeater channels, but also access a repeater by
transmitting automatically in sequence.
Thus the repeater search scan function searches an available
repeater in the area even if the repeater is not in use.
IMPORTANT!:
A microphone should be on hook to start scanning.
The repeater search scan detects a signal on the repeater
output, CH 1 to 8, only. Therefore, repeater availability can-
not be guaranteed even the repeater scan is stopped,
because the scan will stop if any activity is detected. (The
scan is cancelled when receiving a signal, such as stations
communicating in simplex operation on a repeater output
channel.)
q Push [SCN] (Scan Start/Stop) for 1 sec. to enter the scan
type selection mode.
w Push []/[]to select the repeater scan.
e Push and hold [SCN] (Scan Start/Stop) to return to Normal
mode.
RS appears when the repeater scan is selected.
r Push [SCN] (Scan Start/Stop) to start the repeater scan.
See the flow as described at right for repeater search scan
details.
t When receiving a signal on the repeater channel, scan
stops.
3 high beeps sound when receiving a signal, and 3 low beeps
sound when no signal receiving.
y Push [SCN] (Scan Start/Stop) to cancel the scanning man-
ually.
Repeater search scan
Repeater scan
Push [] or []
IC-400PRO.qxd 03.6.19 6:13 PM Page 13 (1,1)
14
4
SCAN OPERATION
4
DD
Repeater search scan ow
Searches for signal on
repeater output signal.
Scanning channel
is displayed.
Access to the repeater
automatically.
Wait for a signal from
the repeater.
Access to the next re-
peater automatically.
Scan is cancelled automatically.
Scan
When not reply signal is received.
IC-400PRO.qxd 03.6.19 6:13 PM Page 14 (1,1)
15
5
GROUP MODE OPERATION
Group mode
(CTCSS)
D Setting the CTCSS frequency
The IC-400PRO is equipped with 51 CTCSS frequencies for
group mode operation. The group mode operation provides
communication with silent stand-by since you will only receive
calls from group members using the same CTCSS frequency.
First of all, set the same CTCSS frequency for all group mem-
bers transceivers.
To access the IC-40Jr or IC-4088S operating in Group mode
(including Smart-Ring function), the same CTCSS frequency
should be set. Select the CTCSS frequency matching the
group code that is set to the IC-40Jr or IC-4088S, referring to
the Group code/frequency table in the next page.
For example, when group code 01 is set to the IC-40Jr/IC-
4088S, select 67.0 as CTCSS frequency.
NOTE: Only the stations with the same CTCSS frequency
or matching the group code can be heard in group mode
operation.
To turn ON the group mode operation:
q Push []/[]to select the desired channel.
w While in Function mode, push [
O
]
(Bank/Func)
for 1 sec.
to enter Set mode.
Push [
O
]
(Bank/Func)
for 1 sec. to enter the transceiver into
Function mode.
The bank and channel can be selected after entering Set mode.
e Push [MONI] for 1 sec. to enter the individual setting.
r Push [MONI] several times until CT appears.
t Push []/[]to select the desired frequency.
When OFF is displayed, push [DUP] to enables the tone fre-
quency selection, in advance.
y Push [MONI] for 1 sec. to exit the individual setting, then
push [
O
] for 1 sec. to exit Set mode.
The under bar indicator appears. (p. 4)
CT appears
[MONI]
Channel*Bank*
The keys under these indicators can be activated.
*The bank and channel number
are continuously displayed af-
ter entering set mode.
Push [
O
] for 1 sec.
[
IC-400PRO.qxd 03.6.19 6:13 PM Page 15 (1,1)
16
5
GROUP MODE OPERATION
5
To cancel the group mode operation:
q While in Function mode, push [
O
]
(Bank/Func)
for 1 sec.
to enter Set mode.
Push [
O
]
(Bank/Func)
for 1 sec. to enter the transceiver into
Function mode.
w Push [MONI] for 1 sec. to enter the individual setting.
e Push [MONI] several times until CT appears.
r Push [DUP] to select OFF (group mode OFF).
t Push [MONI] for 1 sec. to exit the individual setting, then
push [
O
] for 1 sec. to exit Set mode.
The under bar indicators disappear.
DD
Group code/frequency table (unit: Hz)
Code
01
---
---
02
03
04
05
06
07
08
09
Freq.
67.0
69.3
71.0
71.9
74.4
77.0
79.7
82.5
85.4
88.5
91.5
Code
10
11
12
13
14
15
16
17
18
19
20
Freq.
94.8
97.4
100.0
103.5
107.2
110.9
114.8
118.8
123.0
127.3
131.8
Code
21
22
23
24
25
---
26
---
27
---
Freq.
136.5
141.3
146.2
151.4
156.7
159.8
162.2
165.5
167.9
171.3
Code
28
---
29
---
30
---
31
---
---
32
Freq.
173.8
177.3
179.9
183.5
186.2
189.9
192.8
196.6
199.5
203.5
Code
---
33
34
35
---
36
37
38
---
---
Freq.
206.5
210.7
218.1
225.7
229.1
233.6
241.8
250.3
254.1
OFF
Push [DUP]
What is CTCSS (Continuous Tone Coded Squelch
System) GROUP MODE ?
CTCSS (Continuous Tone Coded Squelch System)
GROUP MODE allows communication with silent stand by.
Only signals containing a specific CTCSS frequency can
open the squelch.
This conveniently eliminates unwanted audio and is useful
in group activities or security related activities where
unwanted output can be a problem. Note that CTCSS
group mode is not privateanyone can receive your calls.
The IC-400PRO is equipped with 51 CTCSS frequency for
CTCSS GROUP MODE use. Selecting a CTCSS frequen-
cy applies it to all 40 operating channels. To temporarily
hear all signals (including noise) push and hold [MONI]. Do
not use CTCSS GROUP MODE if you want to hear signals
on all channels.
: Stands for the recommended CTCSS frequency. In
case a frequency other than at left is used, sometimes
the squelch system may not performed correctly.
IC-400PRO.qxd 03.6.19 6:13 PM Page 16 (1,1)
17
6
SELCALL OPERATION
General
In addition to the group mode operation for silent stand-by,
the SelCall operation is available. SelCall is an abbreviation
for Selective Calling. In Group mode operation, there are 51
ways to make an individual call with CTCSS frequencies ver-
sus 100,000 ways to make an individual call with Selcall using
5tone.
SelCall allows you to selectively call another unit that is oper-
ating on the same channel.
SelCall can also call the entire group on that channel using
group call code.
The caller station code/name, status message, Answer Back
function, automatic scan start function, etc. are available with
SelCall operation. A variety of functions are available depend-
ing on the setting with the CS-400PRO
CLONING SOFTWARE
.
See the help le for setting details.
Calling operation
D TX code channel selection
The [MONI] (Call) key (in Function mode) enables you to
change the TX code channel with []/[]keys.
TX code is transmit SelCall code. Max. 32 TX code chan-
nels can be pre-programmed into the IC-400PRO using
the optional CS-400PRO
CLONING SOFTWARE
.
To select a TX code channel:
q While in Function mode, push [MONI] (Call) for 1 sec. to
enter the TX code channel selection mode.
Push [
O
]
(Bank/Func)
for 1 sec. to enter the transceiver into
Function mode.
w Push []/[]to select the desired TX code channel.
Push [] or []
The TX code or TX code
channel name (if program-
med) is displayed.
Push [MONI] for 1 sec.
IC-400PRO.qxd 03.6.19 6:13 PM Page 17 (1,1)
18
6
SELCALL OPERATION
6
e Push [MONI] (Call) to set the TX code channel, and return
to Function mode.
r Push [MONI] (Call) to transmit the code on the selected
channel.
CONVENIENT!
The TX code channel name can be assigned to the all 32
TX code channel via the optional CS-400PRO
CLONING
SOFTWARE
. The TX code channel name allows you to easy
to select the channel, nd the channel user, and so on.
The long tone function is useful and provides you to proper
individual or group call even through a repeater, or when the
calling station is in scanning operation. The long tone func-
tion can be activated in Set mode. (p. 30)
D TX code number edit
The [MONI] (Call) key (in Function mode) enables you to
change the TX code contents within the allowable digits.
The group call function works by allowing you to edit a special
group code into the last 2 digits position of the SelCall ID
code.
To edit a TX code:
q While in Function mode, push [MONI] (Call) for 1 sec. to
enter the TX code channel selection mode.
Push [
O
]
(Bank/Func)
for 1 sec. to enter the transceiver into
Function mode.
Push []/[]to select the desired TX code channel, if desired.
w Push [MONI] (Call) for 1 sec. again to enter the TX code
edit mode.
e Push [MONI] (Call) to select the desired digit to be edited.
Editable digit blinks
Push [MONI]
The first digit starts blinking
Push [MONI] for 1 sec.
Push [MONI]
Appears while transmitting
Push [MONI]
IC-400PRO.qxd 03.6.19 6:13 PM Page 18 (1,1)
19
6
SELCALL OPERATION
r Push []/[]to set the desired code.
Select when group code is set.
t Push [MONI] (Call) to set the code and the editable digit
move to right automatically.
y Repeat step r and t to input all allowed digits.
u Push [MONI] (Call) to set the TX code.
i Push [MONI] (Call) to return to Function mode.
o Push [MONI] (Call) to transmit the code on the selected
channel.
NOTE: The TX code editable digit can only be set/changed
with the optional CS-400PRO
CLONING SOFTWARE
.
Push [MONI]
Appears while transmitting
Push [MONI]
Push [MONI]
Push [] or []
IC-400PRO.qxd 03.6.19 6:13 PM Page 19 (1,1)
20
6
SELCALL OPERATION
6
When receiving a call
D Receiving an individual call
When receiving an individual call (default setting);
- PiRo beeps sound repeatedly for 10 sec.
- Transmits the answer back call with single tone for 2 sec.
- The received ID code is displayed and memorised into the trans-
ceiver.
- “” and “” appear, and the channel turns Audible condition
(mute is released)
RX code is receiving SelCall code. Max. 8 RX code chan-
nels can be pre-programmed into the IC-400PRO using
the optional CS-400PRO
CLONING SOFTWARE
.
You can set the transceiver condition when receiving an indi-
vidual call using the CS-400PRO
CLONING SOFTWARE
. See the
help le for setting details.
Recall the memorised RX code:
q During in Function mode, push [SCN] (ID-MR Select) to
display the memorised RX code.
w Push []/[]to select the desired RX code.
e Push [MONI] (Call) to transmit the code on the selected
channel.
D Receiving a group call
When receiving a group call (default setting);
- PiPi beep sounds.
- GROUP is displayed.
- “” blinks and “” appears, and the channel turns Audible con-
dition (mute is released)
You can set the display condition when receiving a group call
with the CS-400PRO
CLONING SOFTWARE
. See the help le for
setting details.
D Answering a call
q When receiving a call (individual or group call), the indica-
tors appear as at left/above.
w Push any key to return to the condition before receiving a
call.
“” still lights/blinks on the display.
e Then push [PTT] to communicate via the microphone with
the caller, if desired.
BlinksAppears
Appear
IC-400PRO.qxd 03.6.19 6:13 PM Page 20 (1,1)
21
6
SELCALL OPERATION
The SelCall mute condition allows silent operation until you
are selcalled.
q While in Function mode, push [DUP] (CONT/SGL) and
select the single tone to activate the SelCall mute
(Inaudible condition).
Push [
O
]
(Bank/Func)
for 1 sec. to enter the transceiver into
Function mode.
When the single tone is selected, SGL is displayed briey, and
the under bar appears as below.
w Push [
O
] for 1 sec. to enter Set mode, and push for 1 sec.
again to return to Normal mode.
e To monitor the channel;
Push [MONI] (Moni(Audi)) for 1 sec. to release the SelCall
mute (audio is emitted; Audible condition).
“” appears.
r To enable SelCall mute;
When “” appears, push the key to mute the channel
(sets to Inaudible).
“” disappears.
NOTE: The unmute condition (Audible condition) may
automatically return to the mute condition (Inaudible con-
dition) after a specied time period depending on the pre-
setting.
Push [MONI]
Push [MONI] for 1 sec.
Appears
Push [
O
] for 1 sec.
Normal mode
Push [DUP]
Appears
Setting the silent stand-by condition
IC-400PRO.qxd 03.6.19 6:13 PM Page 21 (1,1)
22
7
OTHER FUNCTIONS
6
7
These functions have an answer back feature, and allows you
to confirmation of whether or not a call has reached the
receiving party even if the operator is temporarily away from
the transceiver. The Smart-Ring is for manual, and the ATS
is for automatic conrmation. Both functions are compatible
with the IC-40Jr and IC-4088S.
[ATS/S-ring] must be assigned to the desired programma-
ble key using the optional CS-400PRO
CLONING SOFTWARE
.
D Smart-Ring
q Set the same CTCSS frequency (or group code) for all of
the group transceivers. (See p. 15)
w Push [ATS/S-ring].
A beep is emitted and “” appears on the display.
When a member of a specic group answers a call, “” blinks.
When no answer back is received, the transceiver emits short
faint beep tones.
e Push [PTT] to answer and to stop the ashing.
NOTE: This function is available only when the called sta-
tion has set the same CTCSS frequency (or group code)
and the same operating channel as you.
D ATS
Push [ATS/S-ring] for 1 sec. to turn the function ON.
The transceiver starts to send a searching signal every 60 sec.
•“ and “” appear on the display when the function is activat-
ed.
- When the transceiver receives an answer back signal, “” stays
on the display until the next search transmit.
- If no reply is received, “” blinks until the next search transmit.
NOTE:
The setting at left is for the calling station only. A called
party automatically sends an answer back signal without
any presettings. All IC-400PROs operating on the same
operating channel will answer back to the call in the sur-
roundings communications area.
When the CTCSS frequency (or group code) is set to the
IC-400PRO, this function is available only for the same
frequency (code) setting.
Appear
Appears while transmitting
Blinks when a group
member answers a call.
Smart-Ring and ATS (Automatic Transponder System)
KEY ASSIGNMENT
IC-400PRO.qxd 03.6.19 6:13 PM Page 22 (1,1)
23
7
OTHER FUNCTIONS
The voice scrambler function provides communication priva-
cy. The optional UT-109/110 (#02)
VOICE SCRAMBLER UNITS
provides high performance private communication between
stations with the same scrambling codes. The scrambler is
not compatible with the IC-4088Ss scrambler system.
The scrambler group code is must be set in advance using
the optional CS-400PRO when the UT-110 is installed.
ACA class licence inhibits using this function in channels
5, 11 and 35, or while accessing a repeater.
q Push []/[]to select the desired channel.
Except for the channels 5, 11 or 35.
w While in Function mode, push [
O
]
(Bank/Func)
for 1 sec.
to enter Set mode.
Push [
O
]
(Bank/Func)
for 1 sec. to enter the transceiver into
Function mode.
e Push [MONI] for 1 sec. to enter the individual setting.
r Push [MONI] several times until SCR appears.
t Push [DUP] to turn the scrambler function ON.
t Push []/[]to select the desired code.
Available codes;
- UT-109 (Non-rolling type): 1 to 32
- UT-110 (Rolling type): 1 to 255
y Push [MONI] for 1 sec. to exit the individual setting, then
push [
O
] for 1 sec. to exit Set mode.
Push [] or []
The scrambler
code appears
Push [DUP]
SCR appears
Push [MONI]
Channel*Bank*
The keys under these indicators can be activated.
*The bank and channel number
are continuously displayed af-
ter entering set mode.
Push [
O
] for 1 sec.
Voice scrambler function (optional UT-109/110 is required)
[
IC-400PRO.qxd 03.6.19 6:13 PM Page 23 (1,1)
24
7
OTHER FUNCTIONS
7
DTMF
transmission
Up to 8 DTMF (Dual Tone Multiple Frequency) code channels
are available for storage of often used DTMF codes of up to
24 digits and the automatic DTMF transmission function is
available without using the optional HM-100TN
DTMF MICRO
-
PHONE
.
DTMF signaling can be used for remote control via phone
patch system, etc.
[DTMF Autodial] must be assigned to the desired pro-
grammable key using the optional CS-400PRO
CLONING
SOFTWARE
.
To transmit a DTMF code:
q Push [DTMF Autodial]a DTMF code channel appears.
w Push []/[]to select the desired DTMF channel.
e Push [DTMF Autodial] to transmit the DTMF code the
selected DTMF channel.
If the transceiver has a [Re-dial] key, the last transmitted
DTMF code is sent immediately when pushing the key.
Channel lock
function
This function electronically locks [], [], [SCN] (Scan
Start/Stop)/(ID-MR Select), [MR-CH 1] to [MR-CH 4] and
[Hook Scan] keys (if assigned) to prevent accidental chan-
nel change.
[Ch Lock] must be assigned to the desired programmable
key using the optional CS-400PRO
CLONING SOFTWARE
.
Push [Ch Lock] for 1 sec. to turn the channel lock func-
tion ON and OFF.
Push [Ch Lock]
for 1 sec.
KEY ASSIGNMENT
DTMF code channel appears.
KEY ASSIGNMENT
IC-400PRO.qxd 03.6.19 6:13 PM Page 24 (1,1)
25
7
OTHER FUNCTIONS
The receive frequency in the private bank channels can be
re-programmed within 450 to 500 MHz frequency range
depending on the setting.
q Push []/[]to select the desired channel.
w While in Function mode, push [
O
]
(Bank/Func)
for 1 sec.
to enter Set mode.
Push [
O
]
(Bank/Func)
for 1 sec. to enter the transceiver into
Function mode.
The bank and channel can be selected after entering Set mode.
e Push [MONI] for 1 sec. to enter the individual setting.
r Push [MONI] several times until the RX frequency appears.
t Push [DUP] to enter the RX frequency setting mode.
y Push [DUP] to select the desired digit to be edited.
u Push []/[]to set the desired number.
Push [] or []
Push [DUP]
The first digit starts blinking.
Push [DUP]
RX frequency appears
Push [MONI]
Channel*Bank*
The keys under these indicators can be activated.
*The bank and channel number
are continuously displayed af-
ter entering set mode.
Push [
O
] for 1 sec.
RX frequency setting (for private banks only)
[
IC-400PRO.qxd 03.6.19 6:13 PM Page 25 (1,1)
26
7
OTHER FUNCTIONS
7
i Push [DUP] to set the number and the editable digit move
to right.
o Repeat step u and i to input the desired frequency.
!0 Push [DUP] to set the RX frequency.
!1 Push [MONI] for 1 sec. to exit the individual setting, then
push [
O
] for 1 sec. to exit Set mode.
CONVENIENT!
The 5-digit channel name can be programmed using the
optional CS-400PRO
CLONING SOFTWARE
.
Wide/Narrow
function
This function temporarily changes the bandwidth between
wide or narrow on Private channels only.
[Wide/Narrow] must be assigned to the desired program-
mable key using the optional CS-400PRO
CLONING SOFT
-
WARE
.
Push [Wide/Narrow] to toggle the bandwidth between
wide or narrow.
Push
[Wide/Narrow]
KEY ASSIGNMENT
Push [DUP]
Push [DUP]
IC-400PRO.qxd 03.6.19 6:13 PM Page 26 (1,1)
27
7
OTHER FUNCTIONS
Set mode
Set mode allows you to change seldom used common set-
ting for the transceiver, or individual setting for the operating
channel. In this case you can customize transceiver opera-
tion to suit your preferences and operating style.
To enter the common setting for the transceiver, or individ-
ual setting, push the appropriate key in step t below.
Entering the Set mode:
q Push [
O
] (Bank/Func) to enter the channel bank selection
mode. Then select the desired channel bank with []/
[]key. Push [
O
] (Bank/Func) again to exit the channel
bank selection mode.
w Push []/[]to select the desired channel when you
change the individual setting.
*The bank and channel can be selected after entering Set mode.
e Push [
O
]
(Bank/Func)
for 1 sec. to enter the Function
mode.
r Push for 1 sec. again to enter the Set mode.
t Push [SCN] for 1 sec. to change the common setting, or
[MONI] for the individual setting.
y Push [SCN]/[MONI] (the same key that you pushed in
step t) to select the appropriate item. Then, push []/
[]to set the desired level/mode or [DUP] to turn the func-
tion ON or OFF (depending on the selected item).
u After pushing [SCN]/[MONI] (the same key that you
pushed in step t) for 1 sec., push [
O
] for 1 sec. to exit Set
mode.
NOTE: The displayed items can be changed depending on
the pre-setting via the optional CS-400PRO
CLONING SOFT
-
WARE
.
See next page for Set mode ow chart.
Channel*Bank*
The keys under these indicators can be activated.
*The bank and channel number
are continuously displayed af-
ter entering set mode.
IC-400PRO.qxd 03.6.19 6:13 PM Page 27 (1,1)
28
7
OTHER FUNCTIONS
7
Push [SCN] for 1 sec.
Backlight
CTCSS frequency
Scrambler
Normal mode
Set mode
Function mode
Beep
AF Min level
Auto power OFF
Scan Stop Timer
SelCall Form
Long Tone
SelCall Sequency Station code ID code
Squelch level
Push [
O
] (Bank/Func)
for 1 sec.
Push [
O
] (Bank/Func)
for 1 sec.
Push [MONI]
for 1 sec.
Push [SCN]
Push [MONI]
Lockout
Time-out timer
Appears when accessing user set mode
from CB bank only.
Appears when accessing user set mode
from private bank only.
RX frequency
Individual setting
Common setting
DD
Set mode ow chart
The following ow chart describes Set mode details.
IC-400PRO.qxd 03.6.19 6:13 PM Page 28 (1,1)
29
7
OTHER FUNCTIONS
DD
Common setting
Backlight condition
The transceiver has display backlight for night-time opera-
tion. Select the desired condition.
- OFF : Backlight never lights.
- DIM : Backlight lights dimly.
- AUT : Backlight turns ON when no signal applied to external DIM
terminal, and lights dimly when a signal applied to external
DIM terminal (optional OPC-617
ACC CABLE
is required).
- ON : Backlight lights continuously.
Beep condition
The key-touch beeps can be turned ON and OFF.
Squelch level
Adjust the noise squelch level within a 0 to 255 range.
- The lower the set value is the easier it is for the squelch to open,
and easier for the scan to stop.
AF Min level
Adjust the minimum audio output level within a 0 to 255
range.
Auto Power OFF
The transceiver can be set to automatically turn OFF after 2
hours in which no operations are performed and receiving
no signal.
To cancel the function, select OFF in Set mode.
Turn OFF after 2 hours This function is OFF
0 setting 255 setting
0 setting 120 setting
Beep ON Beep OFF
(silent operation)
AUT setting Continuously ON setting
Backlight is OFF DIM setting
IC-400PRO.qxd 03.6.19 6:13 PM Page 29 (1,1)
30
7
OTHER FUNCTIONS
7
Lockout CB
Select the transmission lockout (temporary transmission
inhibit) capability from OFF, Busy and Rpt 1 for CB mode.
- OFF: No restriction for receiving a signal.
- BUSY (Busy Lockout): Transmission is inhibited while receiving a
signal.
- RPT1 (Repeater Lockout (1)): Transmission is permitted only while
receiving a matched CTCSS tone, or receiving no signal.
Scan stop timer
The scan resume condition can be selected as a pause or
timer scan.
- T-5/10/15 : Scan pauses 5/10/15 sec. while receiving a signal.
- P-5 : Scan pauses until the signal disappears and then
resumes 5 sec. thereafter.
SelCall Format
Select the SelCall format from CCIR, ZVEI1, ZVEI2, DZVEI,
EEA, EEA2, DAPL, TP40, TP100, DTMF, IC20 and INH.
The optional UT-108
DTMF DECODER UNIT
is required to select
DTMF.
TP40 and TP100 are compatible with other manufactures CB
transceiver SelCall.
Long tone
Select the long tone function to activate the long tone capa-
bility for CB mode.
SelCall sequence
Select the own ID code sending sequence from ST and
ST-ID.
- ST : Does not send the ID code.
- ST-ID: Sends the ID code after sending station or group code.
STN+ID settingSTN setting
The long tone function is ON The long tone function is OFF
TP40 setting SelCall inhibit setting
T-15 settingP-5 setting
Lock-out function is OFF.
Rpt1 setting
Busy setting
IC-400PRO.qxd 03.6.19 6:13 PM Page 30 (1,1)
31
7
OTHER FUNCTIONS
STN code (Station to be called)
Select the station code channel with []/[]key.
Set the desired station code following the steps as below.
q
While the station code is displayed,
push [DUP] to
enter the station code edit mode.
w Push [DUP] to select the desired digit to be edited.
Editable digit blinks
e Push []/[]to set the desired code.
Select when group code is set.
r Push [DUP] to set the code and the editable digit
move to right automatically.
t Repeat step e and r to input all allowed digits.
y Push [DUP] to set the station code.
ID code (Self ID number)
Select the ID code channel with []/[]key.
Set the desired ID code in the same way as the station
code setting.
The ID code 12345
Push
[DUP]
The code channel name is displayed.
(if programmed)
The station code 11111
Push
[DUP]
The code channel name is displayed.
(if programmed)
IC-400PRO.qxd 03.6.19 6:13 PM Page 31 (1,1)
32
7
OTHER FUNCTIONS
7
DD
Individual setting
CTCSS function
Select CTCSS frequency.
Time-out timer
Turn the time-out timer function ON or OFF to limit continu-
ous transmission.
Scrambler function
(The optional UT-109/110 is required)
Set the scrambler codes to provides high performance pri-
vate communication between stations with the same codes.
ACA class licence inhibits using this function in channels 5,
11 and 35, or while accessing a repeater. (p. 23)
- UT-109: 1 to 32
- UT-110: 1 to 255
The scrambler group code is must be set in advance using
the optional CS-400PRO when the UT-110 is installed.
The scrambler code is 1
The scrambler code is 255
Scrambler function is OFF
Push [DUP]
Push [DUP]
Push
[ ] or [ ]
Time-out timer function
is ON
Time-out timer function
is OFF
Push
[ ] or [ ]
CTCSS frequency 67.0
CTCSS frequency 88.5
CTCSS function is OFF
Push [DUP]
Push [DUP]
Push
[ ] or [ ]
IC-400PRO.qxd 03.6.19 6:13 PM Page 32 (1,1)
33
7
OTHER FUNCTIONS
RX frequency
The receive frequency can be re-programmed from the
transceiver if permitted. (p. 25)
q While the receive frequency is displayed, push [DUP] to
enter the RX frequency setting mode.
w Push [DUP] to select the digit to be edited.
e Push []/[]to set the desired number.
r Push [DUP] to set the number and the editable digit
move to right.
t Repeat step e and r to input the desired frequency.
y Push [DUP] to set the RX frequency.
Receive frequency is 450.000000
Push
[DUP]
IC-400PRO.qxd 03.6.19 6:13 PM Page 33 (1,1)
34
8
PROGRAMMABLE FUNCTION KEYS
The following functions can be assigned to [MONI], [SCN],
[DUP], [
O
], [ ] and []programmable function keys with
the optional CS-400PRO
CLONING SOFTWARE
.
In the following explanations, programmable function names
are bracketed. The specic switch used to activate the func-
tion depends on programming.
CH UP AND DOWN KEYS
In standby condition, push to select an operating channel.
After pushing [BANK/FUNC], push to select the desired
channel bank.
*The private channels are set in the channel bank 2 to 8. Select
the desired channel bank before operating the private mode.
BANK/FUNC KEY
Push to enter channel bank selection mode.
In channel bank selection mode, push []/[]to select the
desired channel bank.
Push for 1 sec. to toggle Function mode, Set mode or
Normal mode.
Returns to the Normal mode automatically after 30 sec. when no
key operations are performed in Function or Set mode.
NOTE: This key should be assigned to Normal/Function
mode respectively to change the key mode.
SCAN START/STOP KEY
Push to start or stop the scan.
Push and hold to enter the scan type selection mode.
Push [CH Up]/[CH Down] to select the desired scan type.
In scan type selection mode, push to set the channel as a
tag channel.
S
appears for tag channels.
NOTE: Place the microphone on hook to start scanning.
Take the microphone off hook to stop scanning.
MR-CH 1/2/3/4 (Private bank only)
Push to select the operating channels 1 to 4 directly.
OUTPUT POWER SELECTION KEYS
Select the transmit output power temporarily, or permanently,
depending on the pre-setting.
See the help le of the optional CS-400PRO
CLONING SOFTWARE
for
the output power level for each selection.
Normal mode
Set mode Function mode
Push [
O
]
for 1 sec.
7
8
IC-400PRO.qxd 03.6.19 6:13 PM Page 34 (1,1)
35
8
PROGRAMMABLE FUNCTION KEYS
MONITOR KEY
Activates one of (or two of) the following functions on each
channel independently:
Push and hold the key to unmute the channel (audio is emitted;
Audible condition).
Push the key to toggle between the mute and unmute conditions
(toggles between Audible and Inaudible).
Push the key to mute the channel (sets to Inaudible only).
Push the key to unmute the channel (sets to Audible only).
Push the key after communication is nished to send a reset code.
NOTE: The unmute condition (Audible condition) may
automatically return to the mute condition (Inaudible con-
dition) after a specied period depending on the pre-set-
ting.
WIDE/NARROW KEY (Private bank only)
Push this key to toggle the bandwidth between wide or nar-
row.
DTMF AUTODIAL KEY
Push this key to display the text of the DTMF channel number
and set the desired channel number via the [CH Up]/[CH
Down] key. Then, push this key again to transmit a specied
DTMF code.
RE-DIAL KEY
Push to send the last transmitted DTMF code.
CALL KEY
Push to transmit the 5tone code on the selected channel.
Push and hold to enter the 5tone code channel/number
selection mode. (pgs. 17, 18)
Push [CH Up]/[CH Down] to select the desired channel/ num-
ber.
ID-MR SELECT KEY
Push to recall the received ID code.
Push [CH Up]/[CH Down] to select the record.
HOOK SCAN
Push to turn the hanger action scan function (automatic scan
start when on hook) OFF temporarily, and push again to turn
the function ON.
ATS/S-RING KEY
Push to transmit the Smart-ring signal to the other station.
Push for 1 sec. to turn the ATS function ON and OFF.
CH LOCK KEY
This function electronically locks [CH Up], [CH Down], [Scan
Start/Stop], [MR-CH 1] to [MR-CH 4], [ID MR Select] and
[Hook Scan] keys to prevent accidental channel change.
IC-400PRO.qxd 03.6.19 6:13 PM Page 35 (1,1)
36
8
PROGRAMMABLE FUNCTION KEYS
8
DUP/PRI KEY
Push to toggle the transmit frequency mode between
duplex and simplex.
Duplex: The set TX frequency is used for the transmission.
Simplex: The set RX frequency is used for the transmission.
Push for 1 sec. to set the selected channel to priority or
normal.
Priority channel is used for group or priority scan.
CONT/SGL KEY
Push to toggle the 5tone mute activity CONT (Continuous
Tone) and SGL (Single Tone).
IC-400PRO.qxd 03.6.19 6:13 PM Page 36 (1,1)
37
9
CONNECTION AND MAINTENANCE
Optional speaker
(SP-22)
Optional cable
(OPC-617)
Antenna
NEVER connect to
a 24 V battery.
+
red:
black:
12V
Battery
Solder
Crimp
NOTE: Use the terminals as
shown below for the cable
connections.
R CAUTION! NEVER re-
move the fuse-holder from
the DC power cable.
e
r
t
w
q
IMPORTANT! The
microphone hanger
connection is neces-
sary to use the scan-
ning function.
Rear panel and connection
IC-400PRO.qxd 03.6.19 6:13 PM Page 37 (1,1)
38
9
CONNECTION AND MAINTENANCE
9
q ANTENNA CONNECTOR
Connects to an antenna. Contact your dealer about an-
tenna selection and placement.
w MICROPHONE HANGER
Connect the supplied microphone hanger to the vehicles
ground for microphone on/off hook functions. (See p. 3)
IMPORTANT!:
The microphone hanger connection is necessary to use
the scanning function. Scan starts when a microphone
on hook.
e DC POWER RECEPTACLE
Connects to a 12 V DC battery. Pay attention to polarities.
NEVER connect to a 24 V battery. This could damage
the transceiver.
r OPTIONAL CABLE (OPC-617)
Connect an external modem unit, dimmer control, etc.
t EXTERNAL SPEAKER JACK
Connect a 48 (5 W) external speaker, if desired.
Mounting the transceiver
The universal mounting bracket supplied with your transceiv-
er allows overhead mounting.
Mount the transceiver securely with the 4 supplied screws
to a thick surface which can support more than 1.5 kg.
Flat washer
Spring washer
When using
self-tapping screws
IC-400PRO.qxd 03.6.19 6:13 PM Page 38 (1,1)
39
9
CONNECTION AND MAINTENANCE
Optional UT-108 installation
Install the optional UT-108 unit as follows:
q Turn the power OFF, then disconnect the DC power cable.
w Unscrew the 4 cover screws, then remove the bottom
cover.
e Install the unit as shown in the diagram below.
r Replace the bottom cover and screws, then re-connect the
DC power cable.
UT-108
Optional UT-109 or UT-110
installation
q Turn the power OFF, then disconnect the DC power cable.
w Unscrew the 4 cover screws, then remove the bottom
cover.
e Cut the pattern on the PCB at the TX mic circuit (MIC) and
RX AF circuit (DISC) as shown below.
r Install the scrambler unit as described in the installation of
optional UT-108 as on the page at left.
t Replace the bottom cover and screws, then re-connect the
DC power cable.
NOTE: Be sure to re-solder the above
disconnected points when you remove
the scrambler units. Otherwise no TX
modulation or AF output is available.
MIC
DISC
Front panel
Front panel
IC-400PRO.qxd 03.6.19 6:13 PM Page 39 (1,1)
40
9
CONNECTION AND MAINTENANCE
9
q
Dimmer cont. IN or
IGSW cont. IN
w AF OUT
e Det. AF OUT
r Mod. IN
t PTT control IN or
y Horn drive cont. OUT
u AF GND
i Det. AF GND
o Mod. GND
OPTIONAL CABLE PIN ASSIGNMENT
t r e w q
o i u y
FTSW control IN
OPC-617
Cut off the bushing as in the
illustration, when you install
the optional OPC-617.
Optional OPC-617 installation
Install the OPC-617 as shown below.
Antenna
A key element in the performance of any communication sys-
tem is an antenna. Contact your dealer about antennas and
the best places to mount them.
Fuse replacement
A fuse is installed in the supplied DC power cable. If a fuse
blows or the transceiver stops functioning, track down the
source of the problem if possible, and replace the damaged
fuse with a new rated one.
Fuse rating: 10 A, IC-F520/F620: 20 A
Cleaning
If the transceiver becomes dusty or dirty, wipe it clean with a
soft, dry cloth.
AVOID the use of solvents such as benzene or
alcohol, as they may damage the transceiver sur-
faces.
IC-400PRO.qxd 03.6.19 6:13 PM Page 40 (1,1)
41
10
SPECIFICATIONS
DD
GENERAL
Frequency coverage
CB : 476.425477.400 MHz
Private : 450.000500.000 MHz (RX only)
Mode
CB : 16K0F3E
Private : 16K0F3E (Wide)/8K50F3E (Narrow)
Number of channels
CB : 40 channels/1 bank
Private : 88 channels/7 banks
Channel spacing
CB : ±25 kHz
Private : ±25 kHz (Wide)/±12.5 kHz (Narrow)
Current drain (approx.)
TX : (at 5W) 4 A
RX : Max. audio 1200 mA
Stand-by 300 mA
Power supply voltage : 13.8 V DC
Frequency stability : ±2.5 ppm
Antenna connector : SO-239 (50 )
Usable temperature range : 10°C to +60°C
Dimensions : 150 (W) × 40(H) × 117.5(D) mm
(Projections not included)
Weight (approx.) : 800 g
DD
TRANSMITTER
Output power (at 13.8 V DC) : 5 W
Modulation system :
Variable reactance frequency
modulation
Max. frequency deviation : ±5 kHz
Spurious emissions : 30 dBm
Adjacent channel power : 22 dBm
DD
RECEIVER
Sensitivity (12 dB SINAD) : 0.25 µV typ.
Squelch sensitivity : 0.25 µV typ. (Threshold)
Intermodulation rejection ratio:
70 dB
Spurious response rejection ratio
: 75 dB
Adjacent channel selectivity : 73 dB (Wide)/65 dB (Narrow)
Audio output power : 4.0 W typ. at 10% distortion with a 4
load
All stated specications are subject to change without notice or
obligation.
DD
Channel frequency list
CH
1
2
3
4
5
6
7
8
9
10
Freq.
476.425
476.450
476.475
476.500
476.525
476.550
476.575
476.600
476.625
476.650
CH
31
32
33
34
35
36
37
38
39
40
Freq.
477.175
477.200
477.225
477.250
477.275
477.300
477.325
477.350
477.375
477.400
CH
21
22
23
24
25
26
27
28
29
30
Freq.
476.925
476.950
476.975
477.000
477.025
477.050
477.075
477.100
477.125
477.150
CH
11
12
13
14
15
16
17
18
19
20
Freq.
476.675
476.700
476.725
476.750
476.775
476.800
476.825
476.850
476.875
476.900
IC-400PRO.qxd 03.6.19 6:13 PM Page 41 (1,1)
42
11
OPTIONS
10
11
UT-108
DTMF DECODER UNIT
Provides pager and code squelch capabilities.
UT-109/UT-110
VOICE SCRAMBLER UNITS
UT-109: Non-rolling type (max. 32 codes)
UT-110: Rolling type (max. 1020 codes)
UT-108 UT-109 UT-110
SP-22
EXTERNAL SPEAKER
Compact and easy-to-install. Same
as that supplied with some versions.
Input impedance: 4
Max. input power: 5 W
HM-100TN
DTMF MICROPHONE
Hand microphone with a DTMF key-
pad.
SM-25
DESKTOP MICROPHONE
For base station operation.
Monitor switch is equipped.
OPC-617
ACC CABLE
Provides external terminal connec-
tion.
IC-400PRO.qxd 03.6.19 6:13 PM Page 42 (1,1)
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003 Japan
A-6287D-1AU
Printed in Japan
© 2003 Icom Inc.
IC-400PRO.qxd 03.6.19 6:13 PM Page Z (1,1)
44

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Icom IC-400PRO bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Icom IC-400PRO in de taal/talen: Engels als bijlage per email.

De handleiding is 1,85 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info