5
ENGLISH
EN
Charge control/status indicators
Charge controller 1 x IB503 and 1 x communication module
Communication with vehicle Mode 3, Renault Z.E. Ready
Operating status indicator 4 x RBG LED
Card reader RFID (NFC) Mifare 13.56 Mhz, DESFire, integrated (optional)
Internet / Network ability GPRS (900/1800Mhz), SIM lock free or TCP/IP (at least CAT5
Ethernet)
Communication protocol OCPP 1.5 (JSON)
Backend-connection ICU Connect (optional) or other backend (on request)
Communication with Smart Meter -
Operating conditions
Operating temperature -25°C to 40°C
Relative humidity 5% to 95%
Class of protection I
Degree of protection (housing) IP54
IK Protection IK10
Stand-By consumption C. 20 W
Housing
Type Wall-mounted housing
Fixing type Plug and screw mounting or screwed to a pole (optional)
Material Aluminium
Colour RAL 9010 (Trafc white), Powder coated, semi-gloss
Locking -
Weight C. 6.3 kg
Product