4
ENGLISH
EN
Input/power supply
Power supply Min. 5 x 4 mm² (16 A) / 5 x 6 mm² (32 A)
Rated voltage 230 V / 400 V
Mains connection 25 A 1-phase 230 V 50 Hz (3.7 kW version); 25 A 3-phase 400 V
50 Hz (11 kW version); 40 A 3-phase 400 V 50 Hz (22 kW version)
Rated frequency 50 Hz
Back-up fuse 20 A - 80 A (required on site)
Connecting terminals M20 terminal block, for cable sizes from 12.5 mm - 20.5 mm,
Cable-clamps max. 6 mm² (main switch)
Grounding TN-system: PE-wire
Output/vehicle connection
Connection system 1 x type 1 or type 2 connector in accordance with IEC62196-2
Output Voltage 230 V or 400 V
Max. charging current 16 A, 1-phase or 16 A, 3-phase or 32 A, 3-phase
Max. output 3,7 kW or 11 kW or 22 kW
Shut down (Standby) all contacts
Dynamic load balancing -
Protection/integrated compo-
nents
RCCB Residual-current circuit breaker (RCCB) - external (required on
site)
Energy meter kWh-meter, integrated, MID certied, Modbus
Installation contactor 4-pole (charging procedure activation) at 400 V
Standards/Directives
IEC 61851-1 (2010), IEC 61851-22 (2010), Renault Z.E. Ready Guidelines
2.3 Technical specications
Product