ENGLISH
53
the open phase.
Warning phase:
The time between the command to set the door in
motion and the onset of door movement. If a new
command is given during this phase, the warning
phase ends without subsequent door movement.
Automatic timed return:
Door closes automatically after a preset phase on
reaching the "OPEN" travel limit.
For safety reasons we strongly advise using a photo-
cell or closing edge safety device when the automatic
timed return is activated.
Figure 19
Wiring diagram
Note: In order to carry out the following
steps, the carriage must be engaged
(see fig. 12.4). If the garage does not
have a separate entrance, then the furt-
her points should be carried out from
inside the garage:
Figure 20
Programming the radio receiver to respond to
the selected hand transmitter button
1. Disconnect from the mains by pulling out the plug
2. Press the selected button on the hand transmitter
and keep pressed,
3. then immediately re-insert the mains plug and
keep the hand transmitter button pressed for as
long as the operator lighting flashes. To put into
operation, now proceed to delete the door data
as explained under fig. 21.
Note: If the receiver was already pro-
grammed as desired, the operator
lighting will have flashed just once and
the door data will have been deleted.
You can then proceed immediately to
fig. 22 – putting into operation.
Figure 21
Deleting the door data
1. Disconnect from the mains by pulling out the plug
2. Press the programmed hand transmitter button or
circuit board button (to actuate the circuit board
button, the operator cover must be removed) and
keep pressed,
3. then immediately re-insert the mains plug and
keep the hand transmitter button or circuit board
button pressed for as long as the operator
lighting flashes. If this flashes just once, this
indicates that the door data has been deleted.
You can then proceed to fig. 22 – putting into
operation.
Functions of the operator and the
free-wired relay
Operator without special functions (fac-
tory setting) –
Relay is activated with the operator
lighting, but without flashing
Operator without special functions –
Relay is activated on reaching the
"CLOSE" travel limit (DOOR CLOSED
signal)
Automatic timed closing from "OPEN"
travel limit position after 30 secs. open
phase and 2 sec. warning phase –
Relay is permanently activated during
open and warning phases as well as
when the door is in motion
Automatic timed closing from the
"OPEN" travel limit position after 30
secs. open phase and 2 secs. warning
phase –
Relay flashes slowly during the open
phase and rapidly during the warning
phase: continues to flash normally when
door is in motion
Warning phase (2 secs.) always activa-
ted – Relay is permanently activated
during the warning phase as well as
when the door is in motion
Warning phase (2 secs.) always activa-
ted – Relay flashes rapidly during the
warning phase;
continues to flash normally when the
door is in motion
Warning phase (2 secs.) always activa-
ted –
Automatic timed return from the "OPEN"
travel limit position after 30 sec. open
phase and 2 sec. warning phase –
Relay is permanently activated during
the open and warning phases as well as
when the door is in motion
Warning phase (2 secs.) always activa-
ted –
Automatic timed return from the "OPEN"
travel limit position after 30 secs. open
phase and 2 sec. warning phase –
Relay flashes slowly during the open
phase and rapidly during the warning
phase; continues to flash normally when
the door is in motion
Open phase:
The time the door waits in the "OPEN" travel limit
position. An impulse given during this time restarts