1
HACCP LED display
A green LED appears with icon “ “ indicates a safe cool or fr ozen condition below 6ºC
or appears with icon “
“ indicates a safe holding temperatur e above 65ºC. When tem-
perature is between 6-65ºC, the r ed LED with icon “ “ will appear and indicate that the
temperature is fall en within the HACCP “Danger Zone”.
HACCP Check
Green Red Green
<6ºC 6-65ºC >65ºC
HACCP LCD backlight
Similar to HACCP LED Display , a green L CD backlight appears with icon “ “ indicates a
safe cool or frozen c ondition below 6ºC or appears with icon “
“ indicates a safe holding
temperature abov e 65ºC. When temperature is between 6-65ºC, the r ed LED with icon “
“ will appear and indicate that the temperature is f allen within the HACCP “Danger Zone” .
Tr ouble shooting
The thermometer incorporates visual diagnostic messages
as follows:
‘
’ or ‘ ’ is displayed when the temperatur e being meas-
ured is outside of the measur ement range.
‘ ’ is displayed when the thermometer is exposed to rap -
id changes in the ambient temperature. ‘ ’ is displayed
when the ambient temperature is not in operating r ange, which
is below 0ºC or above 50ºC.
For all over err or massages it is necessary to r eset the ther-
mometer . T o reset it, wait f or auto power off , remove the batt ery
and wait for a minimum of one minute, reinsert the batt ery and
turn on. If the error message r emains please contact the Ser-
vice Department for further assistanc e.
Batteries
The thermometer incorporates visual low battery indic ation as follows:
‘Battery OK’: measure-
ments are possible
‘Battery Low’: battery
needs to be replaced,
measurements ar e
possible
Battery Exhausted’:
measurements ar e not
possible
When the ‘Low Battery’ icon indicatrs the battery is lo w, the battery should be
replaced immediatel y with 2xAAA, 1.5V batteries. Please note: It is important
that the thermometer is off before r eplacing the battery otherwise the ther-
mometer may malfunction.
Dispose of used battery promptl y and keep away fr om children.
Specification
Infrared scan function
(IRT mode)
Thermocouple probe
(K type, Grounded)
(COT mode)
Measurement range -60 ~ 350ºC -60 ~ 350ºC
Operating range 0 ~ 50ºC
Accuracy (T obj = 15-35º C,
T amb= 25ºC)
±0.6ºC
below -5: ±1ºC
-5 ~ 65: ±0.5ºC
above 65: ±1 % of reading
Accuracy (T amb = 23±ºC) -60 ~ 0: ±(1ºC +0.1/
degree)
0 ~ 65: ±1ºC
65 ~ 350: ±1.5% of reading
Emissivity range 0.95 default - adjustable
0.1 to 1 step 0.01
Resolution (-9.9~ 199.9
ºC/ ºF)
0.2ºC, otherwise 1ºC
Distance spot 8:1
Dimension 39,3x52,9x158mm
Weight (with battery)
145g
Battery life typ. 18, min 14 hour continuous use (Alkaline, with
Laser) (Auto power offafter 15 seconds)
EMC/RFI
Readings may be affected if the unit is oper ated within a radio frequency elec-
tromagnetic field str ength of approximat ely 3 volts per meter , but the perf or-
mance of the instrument will not be permanently aff ected.
LED-weergave voor HA CCP
Als er een groen LED-lampje brandt bij het pictogram “ “ geeft dit een veilige koele of
bevror en toestand lager dan 6ºC aan. Als er een groen LED-lampje brandt bij het pict ogram
“
“ geeft dit een veilige bewaartemperatuur hoger dan 65ºC aan. W anneer de tempera-
tuur tussen 6-65ºC ligt, brandt er een rood LED-lampje bij het pictogram “ “ om aan te
geven dat de temperatuur zich in de HACCP-gev arenzone bevindt.
HACCP-contr ole
Groen Rood Groen
<6ºC 6-65ºC >65ºC
Achtergr ondverlichting van het HACCP-L CD
Net als de LED-weergave voor HA CCP , geeft een gr oene achtergr ondverlichting bij het
pictogram “ “ een veilige koele of bevror en toestand lager dan 6ºC aan. Een gr oene
achtergr ondverlichting bij het pictogram “
“ geeft een veilige bewaartemperatuur hoger
dan 65ºC aan. Wanneer de temperatuur tussen 6-65ºC ligt brandt er een r ood LED-lampje
bij het pictogram “ “ om aan te geven dat de temperatuur zich in de HACCP-geva-
renzone bevindt.
Problemen oplossen
De thermometer beschikt over de volgende visuele diagnos ti-
sche meldingen:
‘
’ of ‘ ’ wordt weer gegeven wanneer de gemeten tem-
peratuur buiten het meetbereik valt.
‘ ’ wordt weer gegeven wanneer de thermometer wor dt
blootgesteld aan snelle ver anderingen in de omgevingstempe-
ratuur . ‘ ’ wordt weergege ven wanneer de omgevings-
temperatuur buiten het werkbereik (lager dan 0ºC of hoger
dan 50ºC ) valt.
Bij alle andere foutmel dingen moet de thermometer worden
gereset. Als u de thermometer wilt r esetten, wacht dan tot
deze automatisch uitschakelt, verwijder de batterij en wacht
minimaal één minuut, plaats de batterij terug en schakel de
thermometer weer in. Als de foutmelding daarna nog altijd
wordt weer gegeven, neem dan contact op met de servic eafde-
ling voor verder e hulp.
Batterijen
De thermometer geeft een visuele melding wanneer de batterijen bijna leeg zijn:
‘Battery OK’: u kunt
metingen uitvoeren
‘Battery Low’: de batterijen
moeten worden vervangen,
maar u kunt nog metingen
uitvoeren
Battery Exhausted’:
u kunt geen metingen
uitvoeren
Wanneer het pictogram ‘Low Battery’ v erschijnt, geeft dit aan dat de bat-
terijen bijna leeg zijn en onmiddellijk moet worden v ervangen door 2x AAA
1,5V-batterijen. Houd er rek ening mee dat belangrijk is om de thermometer
uit te schakelen v oordat u de batterij vervangt, omdat er zich anders s toringen
kunnen voordoen.
Gooi gebruikte batterijen direct en op de juiste wijze w eg en houd ze buiten
bereik van kinder en.
Specificaties
Infraroodscanfunctie
(IRT -modus)
Thermokoppelsonde (K-ty-
pe, geaard) (COT -modus)
Meetbereik -60 ~ 350ºC -60 ~ 350ºC
Werkber eik 0 ~ 50ºC
Nauwkeurigheid (T obj =
15-35º C, T amb= 25ºC)
±0.6ºC
onder -5: ±1ºC
-5 ~ 65: ±0,5ºC
boven 65: ±1 % van meting
Nauwkeurigheid (T amb
= 23±ºC)
-60 ~ 0: ±(1ºC +0,1/
graden)
0 ~ 65: ±1ºC
65 ~ 350: ±1,5% van meting
Emissiviteitsbereik 0,95 standaard – instelbaar
van 0,1 tot 1 met stappen
van 0,01
Resolutie (-9,9~ 199,9
ºC/ ºF)
0,2ºC, anders 1ºC
Afstand/meetpunt 8:1
Afmetingen 39,3x52,9x158mm
Gewicht (met batterijen)
145g
Levensduur batterijen typ. 18, minimaal 14 uur continu gebruik (alkaline, met
laser) (automatisch uitschakelen na 15 sec onden)
EMC/RFI
Metingen kunnen worden beïnvloed als het apparaat w ordt gebruikt binnen een
radiofrequente elektr omagnetische veldsterkte van onge veer 3 volt per meter ,
maar de prestaties van het instrument w orden niet permanent beïnvloed.
HACCP-LEDs
Die grün beleuchteten LEDs mit dem darauf abgebildeten Symbol „ “ bedeuten, dass
die Lebensmittel auf eine (sichere) T emperatur unterhalb 6°C abgekühlt bzw . eingefror en
sind. Ebenso bedeutet die grüne Hintergrundbeleuchtung der LEDs, die mit dem Symbol „
“ gekennzeichnet sind, dass das Lebensmittelpr odukt auf eine (sichere) T emperatur v on
über 65°C erhitzt wurde. Beträgt die Pr odukttemperatur zwischen 6 und 65 ºC, leuchtet die
mit dem Symbol „ “ gekennzeichnete LED rot auf , was bedeutet, dass die Pr odukttem-
peratur die HACCP-Sicherheitstemperatur grenze überschritten hat.
HACCP-Kontr olle
Grün Rot Grün
<6ºC 6-65ºC >65ºC
HACCP-Display mit Hintergrundbel euchtung
Ähnlich zu den HACCP-LEDs leuchtet das Display mit dem darauf abgebildeten S ymbol „
“grün auf, was bedeutet, das s das jeweilige Lebensmittel auf eine (sichere) T emper atur
unterhalb 6°C abgekühlt bzw. eingefr oren sind. Ebenso bedeutet die grüne Hinter grund-
beleuchtung des Displays, auf dem das Symbol „
“ erscheint, dass das Lebensmittel-
produkt auf eine (sichere) T emperatur von über 65°C erhitzt wurde. Betr ägt die Produkt-
temperatur zwischen 6 und 65 ºC, leuchtet das mit dem Symbol „ “ gekennzeichnet e
Display rot auf , was bedeutet, dass die Produkttemperatur die HACCP-Sicherheitstempe-
raturgr enze überschritten hat.
Störungen suchen und beseitigen
Folgende Diagnosemeldungen k önnen dem Display entnom-
men werden:
Die „
“ bzw. „ ”-Meldungen zeigen an, dass die ermitt el-
te T emperaturmessung außerhalb der Skala liegt.
Die „ “-Meldung bedeutet, dass das Thermometer
plötzliche Änderungen in der Umgebungstemperatur fest-
gestellt hat. Die „ “-Meldung bedeutet, dass die Um-
gebungstemperatur sich außerhalb des Betriebsbereichs des
Geräts befindet, einschließlich T emperaturen unter 0°C bzw.
über 50°C.
Wird eine Fehl ermeldung erzeugt, muss das Gerät zurück-
gesetzt werden. W arten Sie so lange, bis sich das Gerät auto-
matisch ausschaltet, nehmen Sie den Akku heraus und warten
mindestens eine Minute ab. Legen Sie den Akku erneut ein und
schalten Sie das Gerät ein. Wenn die F ehlermeldung weiterhin
angezeigt wird, wenden Sie sich an die Serviceabteilung, um
weitere Anweisungen zu erhalten.
Akkus
Folgende Akkustandsanzeigen er scheinen auf dem Display:
„Akku geladen“: Messun-
gen können dur chgeführt
werden
„Niedriger Akkustand“:
Der Akku muss ausge-
tauscht werden, es k önnen
weiterhin Messungen
durchgeführt wer den
„Akku leer“:
Messungen können
nicht mehr durchgeführt
werden
Wird die Meldung „Niedriger Akkustand“ angezeigt müssen 2 neue AAA-Batt e-
rien (1,5 V) eingesetzt werden. Achtung: Denk en Sie daran, das Thermometer
auszuschalten, bevor Sie den Akku austauschen, da sonst das Gerät beschädigt
werden kann.
Gebrauchte Akkus sofort entsor gen und außerhalb der Reichweite von Kindern
aufbewahren.
T echnische Daten
Infrarot-Scan-F unktion
(IRT -Modus)
Thermoelementfühler (Typ
K, geerdet) (COT -Modus)
Messbereich -60 ~ 350ºC -60 ~ 350ºC
Arbeitsbereich 0 ~ 50ºC
Messgenauigkeit (T obj =
15-35°C, T amb = 25°C)
±0.6ºC
unterhalb -5: ± 1ºC
-5 ~ 65: ±0,5ºC
oberhalb 65: ±1 % vom
Messwert
Messgenauigkeit (T amb
= 23 ± ºC)
-60 ~ 0: ±(1ºC +0,1/Grad)
0 ~ 65: ±1ºC
65 ~ 350: ± 1,5% vom
Messwert
Emissionsgrad Der werkseitig eingestellte
Emissionsgrad beträgt
0,95. Er ist im Beriech von
0,1 bis 1 in 0,01-Schritten
einstellbar .
Auflösung (-9,9 ~ 199,9
ºC / ºF)
0,2ºC, sonst 1ºC
Abstandsverhältnis zum
Produkt
8:1
Abmessungen 39,3x52,9x158mm
Gewicht (inkl. Akku)
145g
Akkulebensdauer in der Regel 18, aller dings mind. 14 Stunden Dauer
-
betrieb (Alkaline-Akkus, mit Laser-Nutzung) (auto-
matische Abschaltung nach 15 Sekunden)
EMC/RFI
Die Messung ist möglicherweise nicht genau, wenn das Gerät in einem elekt-
romagnetischen Fel d mit einer elektromagnetischen F eldstärk e von ungefähr
RF-Frequenz v on 3 V pro Meter betrieben wir d. Dies hat keine Auswirkung
auf den Betrieb des Geräts außerhalb des einwirkenden el ektromagneti-
schen Felds.
Infrared thermometer with pr obe, Hendi no. 271254
Operating Instructions
This is a two-in-one infrared thermometer f or food service. Combines an infrar ed non-con-
tact thermometer for surface scans with a pr obe thermometer for internal temperature
readings.
The infrared thermometer measur es temperature of an object ’s surf ace. Thanks to the
8-beam laser , aiming is more precise, which provides better accur acy of measurement. The
electronic sys tem of this instrument converts information int o a temperature value which
is displayed on the LCD.
* Multi-beams laser specifies the approximate measur ement area for better targeting.
Non-contact infrared thermomet er function
Simply aim at the tar get with “Infrared Lens ” and press Scan key to display the surf ace tem-
perature. The distanc e to target ratio is 8:1 ther efore the thermometer should be positioned
as close to the target as possibl e.
The newest temperatur e will be updated on the LCD and the measur ement will continue as
long as the Scan (infrared) k ey is pressed. When the Scan key is r eleased, icon “Hold” will
appear on the display and the last measurement will r emain visible for 15 seconds befor e
the device automaticall y turns off.
Mode selection MIN → MAX → LOCK → ºC/ ºF → EMIS
Minimum or maximum mode
• T o utilize the minimum mode, please press Scan key → Mode k ey → Scan key . And keep
pressing Scan k ey for measurement.
• T o utilize the maximum mode, please press Scan key → Mode k ey *twice → Scan key .
And keep pr essing Scan key for measurement. Pr ess Mode to exit minimum or maxi-
mum mode.
Lock mode
The lock mode is particularly useful for c ontinuous monitoring of temperatures. The ther-
mometer will continuously display the temper ature for up to 60 minutes.
T o utilize the lock mode, please press Scan key → Mode k ey *three times → Scan key for
measurement. Hold down the scan k ey to exit lock mode.
ºC or ºF mode
T o change the ‘ºC’ or ‘ºF’ mode, please press Scan key → Mode k ey *four times → Scan key .
Same steps can be tak en when switching from ºF to ºC.
Emissivity
The infrared thermometer is supplied with a default emis sivity of 0.95. The emissivity can
be changed from 0.10 (10E) to 1 (100E). Changes should onl y be carried out by experienced
personnel. For information r elating to the emissivity of specific materials, please contact the
nearest r etailer . Note: non-contact infrared thermometers ar e not recommended for use in
measuring the temperature of shiny or polished metals.
T o change the emissivity, please Scan k ey->Mode key *fiv e times->Scan key f or each 0.01
(1E) adjustment->Mode key .
In contact thermocouple pr obe function
Insert the probe at tar get and press probe k ey to continuously display the temperatur e for up
to 4 minutes, before the de vice automatically turns off . Press the probe k ey for holding to the
last temperature. Pr ess the probe key one more time t o exit hold mode and res tart reading.
1. Do not twist, over-str ess, or rotate the probe in wrong dir ection.
2. Probe can r emain hot right after measuring hot objects.
3. Al ways k eep the probe in folded position when it is not in use. Leaving the
probe in open position can be danger ous.
The probe of contact thermometer may be damaged if the measur ement is out
of specification range.
T o avoid electric shock or damaging thermometer, do not measur e with probe
when voltage exc eeds 24V AC or 60V DC.
HACCP check
The “HACCP CHECK” feature is incorporated to indicate HACCP temper ature range. The
HACCP LED display and HACCP L CD back light indicate whether food product s are in a safe
zone or danger zone in HACCP temperature.
Infrarood thermometer met sonde, Hendi nr . 271254
Gebruiksaanwijzing
Dit is een twee-in-een infraroodthermometer v oor de horeca die een contactloze infr a-
roodthermometer voor oppervlaktescans c ombineert met een sondethermometer voor
interne temperatuurmetingen.
De infraroodthermometer meet de temperatuur v an het oppervlak van een voorwerp.
Dankzij de laser met 8 bundels is richten nauwkeuriger en wor dt er een nauwkeurigere
meting verkregen. Het elektr onische systeem van dit apparaat zet de informatie om in een
temperatuurwaarde die wor dt weergegeven op het LCD-display .
* De laser met meervoudige bundels specificeert het meetgebied, zodat u beter
kunt richten.
Contactloze infraroodthermometer -functie
Richt simpelweg met de infrar oodlens op het te meten punt en druk op de Scantoets om
de oppervlaktetemperatuur weer te geven. De v erhouding afstand/meetpunt bedraagt 8:1
en de thermometer moet daarom zo dicht mogelijk bij het te meten punt wor den geplaatst.
De meest recente t emperatuur wordt bijgewerkt op het L CD-display en de meting gaat door
zolang de Scantoets (infrarood) w ordt ingedrukt. Wanneer de Scant oets wordt losgelaten,
verschijnt het pictogram “Hold” op het display en blijft de laats te meting 15 seconden zicht-
baar . Daarna schakelt het apparaat automatisch uit.
Selecteren modus MIN → MAX → LOCK → ºC/ ºF → EMIS
Minimum- of maximummodus
• Als u gebruik wilt mak en van de minimummodus, druk dan op de Scantoets → Modustoets
→ Scantoets. Houd de Scantoets ingedrukt om een meting te mak en.
• Als u gebruik wilt mak en van de maximummodus, druk dan op de Scantoets → twee k eer
op de Modustoets → Scantoets. Houd de Scantoets ingedrukt om een meting te mak en.
Druk op de Modustoets om de minimum- of maximummodus af te sluiten.
Ver grendelingsmodus
De vergr endelingsmodus is met name handig voor het continu monitoren v an temperatu-
ren. De thermometer geeft de temperatuur gedur ende maximaal 60 minuten continu weer.
Als u gebruik wilt maken van de ver grendelingsmodus, druk dan op de Scantoets → drie
keer op de Modustoets → Sc antoets om een meting te maken. Houd de scantoet s ingedrukt
om de vergr endelingsmodus af te sluiten.
ºC- of ºF-modus
Als u over wilt schakel en van de ºC- naar de ºF-modus, drukt u op de Scantoets → vier
keer op de Modustoets → Sc antoets. U kunt deze stappen ook volgen om over t e scha-
kelen van ºF naar ºC.
Emissiviteit
De infraroodthermometer wor dt geleverd met een standaardemissiviteit v an 0,95. De emis-
siviteit kan worden inges teld op een waarde van 0,10 (10E) tot 1 (100E). Wijzigingen mogen
alleen worden uitge voerd door ervar en personeel. Neem voor informatie over de emissivit eit
van specifieke materialen c ontact op met de dichtstbijzijnde wink elier . Opmerking: contact-
loze infraroodthermometer s worden niet aanbevol en voor gebruik bij het meten van de
temperatuur van glanzende of gepolijste metalen.
Als u de emissiviteit wilt wijzigen, druk dan op de Scantoets->vijf k eer op de Modustoets->
druk voor elke aanpassing van 0,01 (1E) op de Sc antoets ->Modustoets.
Thermokoppelsonde-functie (met contact)
Plaats de sonde op het te meten punt en druk op de Sondetoets om de temperatuur ge-
durende maximaal 4 minuten continu w eer te geven. Daarna schak elt het apparaat auto-
matisch uit. Druk op de Sondetoets om op de laatste temperatuur vast t e houden. Druk
nogmaals op de Sondetoets om de vasthoudmodus af te sluiten en het meten opnieuw te
starten.
1. Ver draai, overbelast of draai de sonde niet in de verkeer de richting.
2. De sonde kan na het meten van hete voorwerpen nog altijd heet zijn.
3. Houd de sonde altijd in de opgevouwen stand wanneer deze niet in gebruik is.
Als u de sonde in de uitgevouwen stand houdt, kan dit ge vaarlijk zijn.
De sonde van de contactthermometer kan beschadigd rak en als de meting
buiten het specificatiebereik valt.
Om elektrische schokken en schade aan de thermometer te v oorkomen, niet
meten met de sonde wanneer de spanning hoger is 24V AC of 60V DC.
HACCP-contr ole
Het apparaat beschikt over de functie “HACCP CHECK” om het HAC CP-temperatuurbereik
aan te geven. De LED-weer gave voor HACCP en achter grondverlichting van het HACCP-L CD
geven aan of voedselproduct en zich wat betreft de HACCP-temperatuur in de v eilige zone
of gevarenzone bevinden.
Infrarot- Thermometer mit Sonde, Hendi no. 271254
Bedienungsanleitung
Die vorliegende Bedienungsanleitung beschr eibt ein 2-in-1-Infrarot-Thermometer , das in
der Gastronomiebranche zum Einsatz k ommt. Das Gerät kombiniert zwei Methoden der
T emperaturmessung: eine berührungslose Infr arotmethode durch Sc annen der Oberfläche
eines Lebensmittelprodukts sowie Kontaktmes sungen mittels einer verbauten Sonde zum
Ablesen der T emperatur im Inneren des Produkts.
Das Infrarot-Thermometer mis st die Oberflächentemperatur des zu untersuchenden
Lebensmittels. Dank des 8-Strahl-Lasers ist der Ziel vorgang präziser , was sich auf eine
höhere Messgenauigk eit auswirkt. Das im Gerät verbaute elektr onische System wandelt
die ermittelten Informationen in einen T emperaturwert um, der anschließend auf dem
LCD-Display angezeigt wir d.
* Der Mehrstrahl-Laser definiert den ungefähr en Messbereich, damit ein genaueres
Abzielen des zu prüfenden Objekts err eicht werden kann.
Berührungslose Infrarot- Thermometerfunktion
Richten Sie die Infrarotlinse auf das Pr odukt und drücken Sie die Scan- Tast e, um die auf
der Produktoberfläche gemessene T emperatur anzuzeigen. Das Verhältnis von Abstand zu
Produkt beträgt 8:1, daher sollte das Thermometer so nah wie möglich am zu scannenden
Produkt platziert wer den.
Wird die (Infrar ot-) Scan- T aste gedrückt gehalten, wird der Sc an fortgesetzt und die T em-
peratur auf dem LCD-Display k ontinuierlich aktualisiert. Wird die Scan-T aste losgelassen
erscheint im Display das „Hold“-Symbol. Der letzte Messwert wir d für weitere 15 Sekunden
angezeigt. Danach schaltet sich das Gerät automatisch aus.
Modusauswahl MIN → MAX. → SPERRE → ºC/ ºF → EMISSIONSGRAD
Min- bzw. Max- Temperaturmodus
• Zum Starten des Minimaltemper aturmodus drücken Sie die Scan- Taste → Modus- Tas-
te → die Scan- T aste. Die Messung mit der gedrückt gehaltenen Scan-T aste fortsetzen.
• Zum Starten des Maximaltemperaturmodus drücken Sie die Sc an-T aste → Modus- T aste
*zwei Mal → die Scan- T aste. Die Messung mit der gedrückt gehaltenen Scan-T aste fort-
setzen. Drücken Sie die Modus- Taste, um den Minimal- bzw . Maximaltemperaturmodus
zu verlassen.
Sperrmodus
Der Sperrmodus ist besonders nützlich, wenn eine k onstante T emperaturüberwachung ge-
wünscht ist. Das Thermometer zeigt die T emperatur 60 Minuten lang an.
Zum Starten des Sperrmodus drücken Sie die Scan- Tas te → Modus-T aste *drei Mal → die
Scan- T aste. Drücken Sie die Sc an-T aste, um den Sperrmodus zu verlassen.
ºC- bzw. ºF-Modus
Um die angezeigte T emperatur in °C bzw. °F anzeigen zu lassen, drücken Sie die Scan- Taste
→ Modus-T aste *vier Mal → die Scan- Taste. Beim Umschalten von ºF auf ºC k önnen zusätz-
liche Schritte ausgeführt werden.
Emissionsgrad
Der werkseitig eingestellte Emis sionsgrad beträgt 0,95. Der Emissionsgrad kann in einem
Beriech von 0,10 (10E) bis 1 (100E) eingestellt wer den. Alle Änderungen sich durch quali-
fiziertes Personal vorzunehmen. Informationen zum Emissionsgr ad bestimmter Materialien
erhalten Sie bei Ihrem nächstgelegenen Händl er . Achtung: Die Temperaturmessung von
glänzenden oder polierten Metallen mittels des berührungslosen Infrar ot-Thermometers
wird nicht empfohlen.
Um den Emissionsgrad zu ändern, drücken Sie die Scan- Tas te -> Modus- T aste *fünf Mal ->
Scan- T aste (das einmalige Drücken ändert den W ert um 0,01 (1E)) -> Modus-T aste.
Thermoelementfühler – Kontaktthermometer
Führen Sie die Sonde in das Pr odukt ein und drücken Sie die Sonden-T aste, um die T em-
peratur bis zu 4 Minuten lang kontinuierlich anzuzeigen. Nach dieser Zeit schaltet sich das
Gerät automatisch aus. Drücken Sie die Sonden- Tas te, um den zuletzt gemessenen T empe-
raturwert zu speichern. Drücken Sie die Sonden- Tas te erneut, um den Speichermodus zu
verlassen und den Lesevor gang erneut zu starten.
1. V erdrehen Sie die Sonde nicht. Üben Sie keinen Druck auf das Gerät aus.
Sonde nicht in die falsche Richtung drehen.
2. Nach dem T emperaturmessvorgang heißer Pr odukte kann die Sonde sehr
heiß werden.
3. Wird die Sonde nicht verwendet, ist sie im zusammengebaut en Zustand
aufzubewahren. Bleibt sie im auseinander gebauten Zustand liegen kann es
Gefahren zur F olge haben.
Die Kontaktthermometersonde kann beschädigt wer den, wenn der zu ermit-
telnde Messwert außerhalb der Spezifikation liegt.
Um einen Stromschlag bzw . eine Beschädigung des Thermometers zu vermei-
den, führen Sie k eine Messungen mit der Sonde durch, wenn die Spannung 24
V AC bzw. 60 V DC überschr eitet.
HACCP-Kontr olle
Das Gerät ist mit der Funktion „HAC CP CHECK“ zur Ermittlung des HACCP- T emperaturbe-
reichs ausgestattet. Die HAC CP-LEDs und das hintergrundbeleuchtete HAC CP-Display zei-
gen an, ob die T emperatur des untersuchten Lebensmittelprodukts eine Grenztemperatur
innerhalb des sicheren HACCP- Temperaturber eichs überschritten hat.
Hendi b.v.
For technical information and Declar ations of Conformity see
www.hendi.eu.
Hendi b.v.
Voor technische inf ormatie en conformiteitsv erklaringen raadpleeg
www.hendi.eu.
Hendi b.v.
Für technische Auskünfte und Konf ormitätserklärungen siehe
www.hendi.eu.
DE EN NL