659867
2
Verklein
Vergroot
Pagina terug
1/28
Pagina verder
Art. No. 0572
FB 04-278 Rev. 0
Date: 10.05.2016
Manual
Argos²
0572
2
Safety Instructions
Foreword 3
Safety instructions 4
Cleaning & Disinfection 8
Getting to know the unit 9
Before the use 10
Area of Application 10
Fill in the spray liquid 10
Operation 11
Application 12
Operation 12
Work positioning 13
Infilling the spray liquid 15
Mounting/Changing the filter 15
Insert the bur 15
Adjusting the speed 16
Spray 16
Drying / changing tool 16
Footswitch 16
Maintance and Care 17
Changing the washer 17
Changing the water filter 17
Cleaning function 18
Cleaning the chuck 18
Maintance overview 19
Handling instructions 20
Troubleshooting 21
Technical Details 23
3
Safety Instructions
The Argos
2
foot care unit was produced according to strict quality criteria and
uses the latest technology in its design. The images in this manual may vary
slightly from the product you have bought as we are constantly developing our
products.
This user manual includes a detailed description and explanation of how to
use the Argos
2
unit. If you have any questions or suggestions you can contact
us by telephone or email.
This user manual belongs with the Argos
2
unit. Keep it somewhere safe. If you
give this product to someone else please include this document as it includes
important information on how to correctly use the product.
Short description of functions
The Argos is a device for the treatment of callus and nails. The handpiece is
compatible with rotating tools such as diamond polishers, steel cutters and
ceramic cutters. These can reach at speeds up to 40,000 rpm and therefore
provide an efficient way of removing tissue. The direction of rotation can be
changed by pressing a button. The integrated spray function emerges reliably
bundles emerging dusts and the integrated filtered suction function effectively
sucks up any dust particles.. The speed of the bur, the amount of spray and
the suction function can be adjusted via knob.
4
Safety Instructions
Children should be supervised not to play with the appli-
ance.
The installation of the working area has to correspond to
the relevant regulations. Set up the unit in such a way, that
the louvers are not covered and the extracted air can es-
cape well.
To avoid the risk of an electric shock, this device might
only be connected to a power supply with protective con-
ductor.
If you pull the power plug it will stop the connection to the
mains power supply. Set up the unit so that the power plug
is always accessible. The power switch should also always
be easily accessible.
Only switch on the unit if the handpiece rests secured in
the handpiece holder, or if you hold it safely in your hand.
Prevent the permeation of liquids into the control unit. The
electronic elements could be damaged.
Clean the outside of the box only with a damped cloth. Be
sure you unplug the unit before.
Only when pulling the mains cable, you can ensure that
the device will be com-pletely disconnected from mains
check the mains cable regularly for damages, and in case
of such let it change or repair from an authorized service center.
Prevent your hair from wrapping itself around moving
parts.
If applicable, wear a hair net.
When working with materials which might create dust or
moisture use a drilling unit with suction- or spray tech-
5
Safety Instructions
nique. Wear a nose and mouth protec-tion. Always follow the
safety instructions provided by the manufacturer of the materials
being formed.
For safety reasons you must always wear disposable
gloves and protective glasses when operating this unit. In
addition, a face mask conforming to EN 14683 type IIR or
EN 149 FFP 2 must also be worn.
When changing the filter it is advisable to wear a face
mask conforming to EN 14683 type IIR or EN 149 FFP 2.
Only use the suction function, if you have installed the suc-
tion filter. Check this filter every 10 operating hours. If it is
full, please exchange it. A filter should be exchanged at
least after 50 operating hours.
Never use the suction to vacuum any liquids (or air/water
fog which contains particles of liquids).
If water leaks from the unit, then a disturbance is present.
The unit has to be separated from the socket and cannot
be used any longer
Only use distilled water plus a sterilizing additive (e.g. hadewe
Aqua Hy item no. 8555). If you use other brands pay attention to
their manuals if you can use them for this purpose. Never use tap
water. In case, you are working with an alcoholic fluid, or other
burnable liquids, there is always the danger of fire or explosion
hazards. Never refill the tank directly over the unit to avoid in
case you accidently spill water, this will flow into the unit.
Change the spray liquid everyday.
Always add disinfection additive to the distilled water.
6
Safety Instructions
Rinse the tank daily and fill it with fresh water every day.
Empty the unit if it is not in use for a longer period of time
(e.g. before vacations). Clean out the tank. Set the spray
function on maximum. Now start the spray function, and the water
will spray for approx. 3 min. The fluid will be blown out of the
complete spray system and handpiece.
Ensure that the patient’s foot and the handpiece are held
firmly in place during the operation. To prevent injury, work
with extreme caution on the foot of the patient, and use only light
pressure
To ensure that the burr/ tool sits firmly in the chuck, do not
work with tools which:
have an oily shaft
are worn
are bent.
Before using the equipment, assure that:
the tool can be pushed far enough into the chuck
(Test this with a dipstick and clean if necessary)
the inserted tool sits properly in the chuck and will not
cant/jam while clamping it
the tool is approved for using it at the max speed (see
manufacturer´s instructions), or only use the speed re-
quired by the instrument
the tool is absolutely dry.
For safety reasons do not change the tool while the motor
is running.
7
Safety Instructions
Switch off the unit immediately if:
the bur comes off during the treatment itself.
the motor blocks during the treatment.
Always follow the operating instructions. Do not carry out
any repairs, modifications or maintenance work yourself.
This is only to be accomplished by an authorized special-
ist. The mains cable may also only be changed by the manufac-
turer or an authorized specialist. Maintenance records may be
supplied to repair workshops and trained technicians upon re-
quest. Never remove the housing, while the equipment is plugged
in as some components are live. A spare parts list may be sup-
plied to qualified persons (repair workshops).
No responsibility can be accepted for unauthorized or improper
tampering with the unit, which nullifies the guarantee and any
other liabilities.
This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
8
Cleaning and disinfection
Cleaning and disinfection
The device is designed to be compatible with rotating in-
struments which do not penetrate the skin or mucosal or
inadvertently may still cause injuries. For this application please
adhere to the cleaning and disinfection instructions provided be-
low.
After every treatment please carry out these steps:
Remove the rotating tool (e.g. bur) first.
To do so, pay attention to the instructions of its manufacturer.
Remove clothing remains through wiping off easily the unit with a
moistened paper cloth. Afterwards clean all surfaces with a disin-
fection cloth (e.g. Mikrozid AF cloths of Schülke and Mayr).
9
Getting to know the unit
1 Display
2 Knob to start the suction and for adjusting the suction level
3 Knob for adjusting the amount of spray
4 Connection for suction hose
5 Lid of the water tank
6 Water tank
7 ON / OFF button (line voltage is not disconnected, unit in
standby)
8 handpiece speed down
9 handpiece speed up
10 Switch for modus change (spray or suction)
11 Switch for turning ON/ OFF the handpiece/ spray
12 Switch for changing running direction of the bur
13 LED (shines during counterclockwise rotation)
14 Foot switch port
1 2 3 4 5 6
10
Before the use
Please read through the instructions
carefully before using the unit and
carefully note the safety advice.
Always keep this manual accessible
to any users of the drill.
Area of application
This device should only be used by
people who have completed a foot
care qualification. Before use the
operator should make themselve
familiar with the device by reading
this manual or being instructed by
another. The device must only be
used in closed spaces. It may be
used in hospitals, in a commercial
environment or in homes. The de-
vice is not intended for use in oper-
ating rooms.
The control unit can be set up in a
cabinet, or can be used as a porta-
ble unit (e.g. in a carry case). It is
suitable for the following scopes:
Foot care: Milling, trimming and
polishing. (Attention: The suction
or spray must be in operation dur-
ing foot care).
Manicure: Grinding, milling and
polishing works.
Fill in the spray liquid
Pull out the spray tank at the grip.
Hold on to the tank cover with one
hand and turn the container of the
tank off.
Now fill it with distilled water and
anti- germ liquid (e.g. AQUA HY
item no. 8555).
Do not exceed the maximum
level when filling the tank.
While screwing back the cover on
the tank, make sure that is closed
correct.
Otherwise there will no pressure be
build up.
Put the tank back in the housing.
The devise is determined of
operating rotating
instruments, which will not
penetrate the skin or murcous
membrane if used appropriate, but
could evoke damages accidently.
Caution: In the area of
pedicure you have to work
with suction techniques
11
Before the use
Operation
The working area must conform to
the conditions described. Set up the
unit in such a way, that the air slits
are not blocked and the extracted
air can escape well. To guarantee
unhindered air flow there must a
gap of at least 12cm to the right of
the device. Position the device so
that the operating buttons are easy
to reach and the outlet of the hose
is a maximum distance of 60cm
from the patient's foot. The unit
should be 30 - 90cm from the floor.
Image: Example of positioning of foot care unit
in treatment room.
Image: Bird's eye view of work area
If you have a foot switch insert its
plug into the port on the right of the
device which displays this sym-
bol .
Make sure, that the tank is filled
with spray liquid.
Check that the filter bag and dust
filter are correctly fitted.
Ensure that the tool is fixed.
On the back of the device you will
find the main power switch. Press
this switch to turn the unit on.
Take up the handpiece
To use the device press the button
(7) on the front of the unit.
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Hadewe Argos2 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Hadewe Argos2 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,64 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Hadewe Argos2

Hadewe Argos2 Gebruiksaanwijzing - Deutsch - 28 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info