Approval and conformity
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Electrical installation
Electrical installation work must only be
performed by a qualified electrician. This work
must be carried out in accordance with the
regulations according to IEC 60364-7-701
(corresponding to VDE 0100 Part 701) as
well as all national and local regulations.
Always switch off the power supply before
making electrical connections.
New installation
During installation, please note:
The lid of the function unit must be removable to permit
maintenance work.
The function unit must not be installed with the lid facing
downwards.
Prepare the wall for the installation, refer to the dimensional
drawing on fold-out page I.
Install function unit, see fold-out page II, Figs. [1] to [9].
Observe printing on the lid.
1. Prepare holes for the function unit as well as slots for
the pipes and vacant tubes, see fold-out page II, Figs. [1]
to [4].
2. A vacant tube must be used when connecting the function
unit to the fitting and the plug power supply.
3. Unscrew screws and remove lid, see Fig. [5].
4. Align and fasten function unit in place, see Fig. [6].
Do not solder the connections.
5. The cold water supply must be connected to the inlet
marked COLD, the hot water to the inlet marked HOT,
see Fig. [7]
GROHE recommends installing isolating valves upstream
of the function unit to facilitate servicing.
6. Seal plug (A) in the unused outlet.
7. Route mixed water outlets to the fitting. Connection
of outlets must be performed from the bottom upwards.
8. Seal plug (B) in the unused outlet.
9. Route connection cable in vacant tube, see Fig. [8].
Several connection cables can be connected together.
10. Attach the plug-in conntector to the plug power supply and
to the fitting, see Fig. [9].
Flush the function unit, see fold-out pages II and III,
Figs. [10] and [11].
1. Remove screw plug (B), see fold-out page II, Fig. [10].
2. Remove the non-return valve (C) and filter (D).
3. Install the flushing plugs (E) in non-return valve seat
recesses, see fold-out page III, Fig. [11].
4. Open the cold and hot water supply.
Flush pipes thoroughly before and after installation
(observe EN 806).
5. Close the cold and hot water supply and remove the flushing
plugs (E), see Fig. [11].
6. Insert the filter (D) and the non-return valve (C), see fold-out
page II, Fig. [10].
7. Install the screw plug (B).
Open hot and cold water supply and check that
connections are watertight.
8. Fit lid and fasten with screws, see Fig. [5].
Maintenance
Inspect and clean all components and replace if necessary.
Disconnect voltage supply.
Close isolating valves.
I. Thermostatic compact cartridge, see fold-out page II
and III, Figs. [5] and [12].
1. Remove screws and detach lid, see fold-out page II, Fig. [5].
2. Remove screw (H) and washer (H1), see fold-out page III,
Fig. [12].
3. Detach plug (J1) and remove servo motor (J).
4. Loosen screw ring (K) using a 34mm tool and remove.
5. If necessary, lever out thermostatic compact cartridge (L)
via recess (L1).
Assemble in reverse order.
Observe the correct installation position of the
thermostatic compact cartridge (L), see detail (L2).
6. Connect plug (J1) to servo motor (J).
7. Connect the voltage supply and open the cold and hot water
supply, see fold-out page II, Figs. [7] and [9].
8. Turn regulating nut (M) until 38 °C appears in the display
of the operating panel of the fitting, see fold-out page III,
Fig. [12].
9. Install servo motor (J).
Readjustment to 38 °C is necessary after every maintenance
operation on the thermostatic compact cartridge.
II. Non-return valve (E), see fold-out page III, Fig. [12].
1. Remove the screw plug (D).
2. Remove the non-return valve (E) and filter (F).
III. Servo motor (N), see fold-out page III, Fig. [13].
Detach plug (N1), remove clip (N2) and and remove servo
motor (N).
IV. Solenoid valve (O), see fold-out page III, Fig. [13].
Detach plug (O1), remove clip (O2) and and remove solenoid
valve (O).
Assemble in reverse order.
Replacement parts
See fold-out page I (* = special accessories).
This product conforms to the requirements of the
relevant EU guidelines.
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Grohe 36067 Ondus bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Grohe 36067 Ondus in de taal/talen: Alle talen als bijlage per email.

De handleiding is 1,28 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info