Example: Data: Keys:
Block No.
Mo, We, Fr. 13:00,
15 second pulse
on Channel 4
Tu, Th, Sa, Su,
h+, h-, m+, m-
I/0 Channel 4
= 15
Store with S
Pulse switching commands can also be assigned to an individual date or a date range.
15. Test run
To check the entered program, it is possible to execute the switching command in time-lapse tempo.
We recommend that you carry out this test run without connected loads so as to exclude the possibility of hazardous moments on machines and
plant.
Keep the key pressed, the briefly press the key . Release both keys.
The relevant next switching command (calendar-based) is searched for and executed.
The output relays are switched on or off accordingly.
Of course, the defined priority and date assingments are taken into account here.
The date and time must be updated again. See Point 6.1.
16. Manual actuation of the switching outputs
The relevant switching outputs can be influenced as follows with the keys 1 to 4.
Automatic mode Manual operation Continuous operation
FIX I / Fix 0
I=ON
0 = OFF
The switching times correspond
to the entered program
If the current switching state is changed
manually, the next switching command is
again executed automatically after the
switching program is entered.
0 = ON
I=OFF
FIX I = continuous ON / FIX 0 = continuous OFF
It is only possible to return to automatic
mode from the switching states FIX 1 and
FIX 0 by pressing the key.