590608
2
Verklein
Vergroot
Pagina terug
1/2
Pagina verder
V / V
Gelijk- / mengspanningsmeting
Direct Voltage / Pulsating Voltage Measurement
V~/ Hz
Wisselspanning – frequentie, zonder/met laagdoorlaatfilter
AC Voltage – Frequency, without/with Low-pass Filter
m
Capaciteit
Kabellengtemeting
Capacitance Cable Length Measurement
A / A A~ / Hz
Gelijk-/gemengde/wisselstroom- / frequentiemeting
DC/Pulsating/Alternating Current/Frequency Measurement
A / Hz
Meting met tangstroomsensor
Measurement with Clip-on Current Transformer
Apparaat- en meetparameters SETUP
Device and Measuring Parameters
COM mA A
V
Temp
aEb
– (+)
+ (–)
V= : 100 V 610 V
020.00
V
DC
AC
TRMS
020.00
V
DC
V
V
V
V
Meetbereiken:
> 15 V AC of/or > 25 V DC:
> 620 V:
Waarschuwingen voor gevaarlijke spanningen:
230
.
0
Caution! Dangerous Voltages:
Measuring Ranges:
max. 600 V (< 10 kHz)
!
P
max
= 6 x 10
6
V x Hz
FUNC
ENTER
V : 10 mV610 V
CLiP = OFF ! SETUP
COM mA A
V
Temp
aEb
max. 600 V (< 10 kHz)
V~: 10 mV610 V
Hz: 1Hz300 kHz
~
!
>620V:
0225.6
V
AC
TRMS
0049.9
Hz
AC
V~
Hz
V~
Hz
V~/Hz & Filter
P
max
= 6 x 10
6
V x Hz
V~ FilFilter actief / active
Hz FilFilter actief / active
Meetbereiken:
Measuring Ranges:
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
CLiP = OFF ! SETUP
COM mA A
V
Tem p
aEb
10.38
F
0V !
!
+
+
10 pF ... 310 F
m
FUNC
ENTER
15.00
m
m
3.100 km/31.000 km
Meetbereiken:
Measuring Ranges:
COM mA A
V
Temp
aEb
k
Setup CAP
Kabeltype = constant !
!
Cable type = constant !
COM mA A
V
Tem p
aEb
~
R
x
~
R
x
1
3
2
Zekering
Fuse
FF 1,6 A / 700 V AC DC
6,3 mm x 32 mm
A
A
003
.
50
m A
DC
003
.
50
m A
DC
AC
TRMS
A
A
Stroom
Current
Meetbereiken:
Measuring Ranges:
FUNC
ENTER
!
I > 1,2 A
A: 0,1 A . . . 1,1 A
A: 3 A . . . 1,1 A
A~
Hz
003
.
50
m A
AC
TRMS
0049
.
1
Hz
AC
FUNC
ENTER
A~
Hz
Meetbereiken:
Measuring Ranges:
A ~: 3 A . . . 1,1 A
Hz: 1Hz30 kHz
!
COM mA A
V
Te mp
aEb
* METRAFLEX
Omzettings-
verhou-
ding
Transforma-
tion ratio
CLIP
Meetbereiken
Measuring
Ranges
Tang
Current
sensor
300
mV
3 V 30 V
1:1
1mV/1mA
0,3 A
3 A 30 A
WZ12C
1:10
1mV/
10mA
3 A 30 A
300
A
WZ12B
Z201A/B
METRAFLEX
1:100
1mV/
100mA
30 A 300 A
3000
A
Z202A/B
METRAFLEX
1:1000
1 mV/1 A
300
A
3000
A
(30kA)
WZ12C
Z202A/B
Z203A/B,*
~
R
x
0035
.
0
A
AC
TRMS
A~
Hz
1:1000
0050
.
1
Hz
AC
1:1000
SETUP
Stroom
Current
0035
.
0
A
1:1000
0035
.
0
A
1:1000
A
A
SETUP
DC
AC
TRMS
DC
TRMS
FUNC
ENTER
FUNC
ENTER
R
i
~ 9 M
R
i
V
V
V~
Hz
bAtt: 2.92 V
verSion: 1.00
dAtE: 13.09.06
tiME: 11:15:19
OCCUP:
100.0%
... InFo
tEMP ...SEt
1nfo
Submenu’s / parameters / Sub-menus / Parameters
rAtE 0:05:00
0.diSP
0000.0/0.0
A.diSP
bArG/Point
CLiP
OFF/1:1...1000
APoFF
10...59min/on
U_ISo 10V/100V
CAP 10 ... 500nF
r_SL 100...3,1K
,
bEEP
01... 90
irStb ir on/oFF
Addr 01...15
dAtE 13.09.
tiME 11:15
C
F
Hoofdmenu’s / Main Menus
opvragen instellen instellen
read set set
... SEnd ... StorE ...
bevestigen
confirm
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
MEASURE
SETUP
0
20
.
00
V
DC
AC
TRMS
R
SL
Lusweerstandsmetingng Doorgangstest
Loop Resistance Measurement Continuity Testing
M ISO @10 V / 100 V (a-b) (a-E) (b-E)
Isolatieweerstandsmeting Meetingangen
Insulation Resistance Measurement Measuring Inputs
F (CAP) / m (a-b) (a-E) (b-E) % (a-b)
Capaciteit (storingsvrij)
galv. signatuurherkenning
Capacitance (low disturbance)
galv. Signature detection
Technische gegevens – Technical Data
1)
bij / at 0 C...+40C
2)
bij functie ZERO actief / with function ZERO active
3)
Vermogensbegrenzing / Power limiting: 6 · 10
6
V · Hz (max. 600 V 1
kHz)
4)
maximale stroomwaarden zie stroommeetbereiken
max. current values see current measuring range
Isolatiemeting – (a-b) (a-E) (b-E)
Insulation Resistance Measurement
1) Stoorspanningsmeting / Interference voltage measurement
Elektrische veiligheid – Electrical Safety
Beschermingsklasse / Protection class II
– volgens /
per
IEC 61010-1:2001/EN 61010-1:2001/VDE 0411-1:2002
Meetcategorie / Measuring Category CAT II / CAT III
Nominale spanning / Nominal Voltage 600 V / 300 V
Verontreinigingsgraad / Pollution degree 2
Test spann i ng / Tes t Volta ge 3,5 kV~
– volgens / per IEC 61010-1/EN 61010-1
Beschermingsklasse / Protection – Behuizing / Housing:
IP54 (drukcompensatie door behuizing/
pressure equalization by
means of the housing)
Tabeluittreksel over de betekenis van de IP-code
Extract from table on the meaning of IP codes
Elektromagnetische Compatibiliteit EMC
Electromagnetic Compatibility EMC
Storingsuitzending / Interference Emission
EN 61326-1:2006 klasse B / class B
Storingsbestendigheid / Interference Immunity
EN 61326-1:2006, EN 61326-2-1:2006
Omgevingsomstandigheden – Ambient Conditions
Nauwkeurigheidsbereik / Accuracy range 0C ... + 40 C
Werktemperatuur / Operating temperature –10 C ... + 50 C
Bewaartemperatuur /
Storage temperature
zonder batterij / without battery – 25 C ... + 70 C
relatieve luchtvochtigheid / relative humidity 40 ... 75 %
condens moet worden uitgesloten / no condensation allowed
Hoogte boven NAP tot / Elevation up to 2000 m maximum
Zekering – Fuse
FF(ultrarapid) 1,6 A / 700 V AC DC
6,3 mm x 32 mm
Uitschakelvermogen /
breaking capacity
:
50 kA (min. 10 kA)
Bij gebruikmaking van een andere zekering vervalt de fabrieksga-
rantie.
If you use other fuses than the one indicated above you forfeit
your product guarantee.
Interne zekeringentest –
Internal Fuse Test
Zekering vervangen – Fuse Replacement
Koppel het apparaat van de meetkring af voordat u
het deksel van het zekeringenvakje openmaakt! Draai
daartoe de (niet te verliezen) sleufschroef naar links.
Licht de zekering eruit met de vlakke kant van het
zekeringendeksel.
Als u het zekeringendeksel weer aanbrengt, moet u de zijde met
de geleidingshaken er het eerst inzetten.
Draai de sleufschroef naar rechts.
Disconnect the instrument from the measuring circuit
before opening the fuse compartment lid! Turn the
(captive) slotted head screw counter-clockwise for
this purpose. Remove the fuse with the flat end of the
fuse compartment lid.
When refitting the fuse compartment lid the side with the guide
hooks must be inserted first. Then turn the slotted head srew
clockwise.
COM mA A
V
Temp
aEb
R
x
R
x
0V !
!
00.000
k
R
SL
000.8
Doorgang
R < 1, 10, 20, 30, 40, 90
R
SL
: 0,1...3,1k
SETUP
Meetbereiken:
Measuring Ranges:
Continuity
R
SL
: 0,1...310
FUNC
ENTER
Drempel
R
SL
> 100, 200, 2...3 k, OL
SETUP
Threshold
R
x
0V !
!
000.00
M
M
300 k/3 M/30 M/300 M
Meetbereiken / Measuring Ranges:
a-b
a-E
b-E
M
ISO
@10V/100V
COM mA A
V
Temp
aEb
ab
aE
Eb
ISO
UISO
100 V
MAN / AUTO
DATA/MIN/MAX
10V/100V/SiGn
Kiezen van de
testspanning
Select
test voltage
UISO ON / OFF
ZERO
ESC
POL / UISO
000.0
UISO
V
DC
AC
TRMS
ISO
100 V
FUNC
ENTER
pol-
a-b
a-E
b-E
CAP
10
.
38
F
15
.
00
m
m
k
FUNC
ENTER
ZERO
ESC
000
.
0
U
ISO
V
DC
AC
TRMS
ISO 100V
POL / U
ISO
CAP
10
.
38
F
15
.
00
m
m
k
FUNC
ENTER
ZERO
ESC
000
.
0
U
ISO
V
DC
AC
TRMS
ISO 100V
POL / U
ISO
CAP
F
sign
V
V
000
.
0
U
ISO
V
FUNC
ENTER
DC
AC
TRMS
ISO
DC
AC
TRMS
MAN / AUTO
DATA/MIN/MAX
lo
V
V/%
ZERO
ESC
hi
V
V/%
100 V
10V/100V/SiGn
* Percentages knipperen / percentage values
blink
Signatuur
Signature
Beslissingswaarde
Decision value
beschikbaar
available
ca. +60 % ... +200%
niet beschikbaar*
not available
< +20 %
Meetbereiken:
300 nF/ 3
F / 10
F
Measuring Ranges:
3,100 km / 31,000 km
0V !
!
+
a-b
Meetbereik
Measuring Range
Meetfouten / Measuring Error
Overbelastbaarheid
1)
Overload capacity
/
300 mV
(
0,5% + 3 D)
2)
1,5% + 3 D
(> 300 D)
600 V
DC
AC
eff
Sinus/
sine
Continu
continuous
3V
(
0,5% + 1 D)
1,5% + 3 D
(> 100 D)
30 V
300 V
600 V
1 Hz ... 300,00 kHz
(0,5% + 1 D)
600 V
3)
max. 10 s
/
300 A
(0,5% + 5 D)
1,5% + 5 D
(> 100 D)
0,3 A
Continu
continuous
3mA
(0,5% + 3 D)
30 mA
300 mA
1A
(0,5% + 5 D)
1,6 A 5 min
1 Hz ... 30,00 kHz
(0,5% + 1 D)
4)
(... % v. MW/rdg. + ... D)
300 0,5 + 3
2)
600 V
DC
AC
eff/rms
Sinus/
sine
max. 10 s
3k
0,5 + 1
30 k
300 k
3M
30 M 2 + 5
R
SL
300 3 + 5
R
SL
3k 3 + 5
300 3 + 5
5,100 V 2 + 5
30 nF (3% + 6 D)
2)
600 V
DC
AC
eff
Sinus/
sine
max. 10 s
300 nF
(1% + 6 D)3 F
30 F
300 F (5% + 6 D)
Meetbereik
Measuring Range
U
ISO
Meetfout
Measuring Error
( % v. MW/rdg + D)
6 ... 110 V
1)
Ri ca. 120 k
3 + 30
5 ... 310,0 k 10//100 V 3 + 5
0,280 ... 3,100 M 10//100 V 3 + 5
02,80 ... 31,00 M 10//100 V 5 + 5
028,0 ... 310,0 M 100 V 5 + 5
IP XY
(1. Cijfer X)
(1
st
digit X)
Bescherming tegen
binnendringende vaste
deeltjes
Protection against
foreign object entry
IP XY
(2. Cijfer Y)
(2
nd
digit Y)
Bescherming tegen
binnendringend water
Protection against the
penetration of water
5
Stofbestendig
dust protected
4
Spatwater
splashing water
Zekering defect
0fuse
A
DC
Fuse defective
?
Zekering testen
Test Fuse
A
A
A~
Hz
!
!
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gossen Metrawatt METRAHIT T-COM PLUS bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gossen Metrawatt METRAHIT T-COM PLUS in de taal/talen: Nederlands als bijlage per email.

De handleiding is 0,47 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Gossen Metrawatt METRAHIT T-COM PLUS

Gossen Metrawatt METRAHIT T-COM PLUS Gebruiksaanwijzing - Nederlands - 80 pagina's

Gossen Metrawatt METRAHIT T-COM PLUS Snelstart handleiding - Deutsch, English - 2 pagina's

Gossen Metrawatt METRAHIT T-COM PLUS Gebruiksaanwijzing - English - 80 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info