776255
4
Verklein
Vergroot
Pagina terug
1/12
Pagina verder
4GMC-I Messtechnik GmbH
2 Safety Precautions
The test adapter has been manufactured and
tested in accordance with the following
regulations:
IEC 61010-1/DIN EN 61010-1/VDE 0411-1
“Regulations for electronic testers and controllers,
part 1: Safety measures for electrical measuring
instruments”
DIN VDE 0404 “Devices for technical safety
testing of electrical equipment, parts 1 and 2.
EN 61326-1 product standard EMC requirements.
Safety is only assured for the user and the test
adapter when used for its intended purpose in
combination with SECUTEST.../SECULIFE ST test
instruments.
In order to maintain flawless technical safety
conditions, and to assure safe use, it is imperative
that you read these operating instructions
thoroughly and carefully before placing your test
adapter into service, and that you follow all
instructions contained herein.
Due to the fact that all tests performed with the AT3-
III E must be executed in combination with a
SECUTEST.../SECULIFE ST test instrument, you must
also read the safety precautions and liability limitations
included in the operating instructions for this
instrument.
Observe the following safety precautions:
Attention!
!
If the red LED (10) remains lit even after
the AT3-III E has been disconnected from
the mains and connected once again, the
test adapter is defective.
If this is the case,
the AT3-III E must be removed from service
and repaired before it is used again.
In order to assure compliance with technical
safety requirements, the AT3-III E test adapter
should only be repaired by the manufacturer.
The AT3-III E must be disconnected from the
mains and from the SECUTEST.../
SECULIFE ST test instrument before it is
opened.
Measurements within electrical systems are prohibited!
The test adapter’s 16 A CEE 3P+N+PE (16)
plug may only be connected to 230/400 V
50 Hz mains power. In order to avoid
undesired shutdown of defective devices
under test, the electrical circuit for the device
under test should be separately fused.
Before connecting the AT3-III E to the mains,
the SECUTEST.../SECULIFE ST test
instrument must first be connected to the
AT3-III E.
Attention!
!
Tests during which mains power is
applied may only be selected with the
function selector switch at the
SECUTEST.../SECULIFE ST test
instrument after safety class I devices
under test have passed the protective
conductor test.
If the protective conductor is defective
(interruptions / reversed conductors), line
voltage may be present at the housing of
a defective device under test, at the
earthing contacts of the test plugs (4 – 7)
and at the safety socket (15)!
•For REASONS OF SAFETY, the device under test
must be turned off before switching to
“MAINS” so that dangerous devices under
test (e.g. a circular saw) can only be switched
on intentionally.
Be prepared for the occurrence of
unexpected voltages at devices under test
(e.g. due to charged capacitors).
Before connecting the device under test to
the test adapter, subject it to a thorough
VISUAL INSPECTION first. Damaged devices
under test must be repaired prior to testing.
Only extension cables which have been
plugged into the test outlets (1 – 4) at the test
adapter may be connected to the device
plugs (4 – 7) at the test adapter.
Due to test adapter design in accordance with
DIN VDE 0404, the “PE” contacts at the
outlets (1 – 4) are only connected to the mains
protective conductor when the SECUTEST.../
SECULIFE ST test instrument has been set for
testing with mains power.
If the test adapter and/or its connector cables
demonstrate visible damage, no longer
function, have been stored for a lengthy
period of time under unfavorable conditions or
have been subject to excessive stress during
transport, it must be assumed that hazard-
free operation is no longer possible. Remove
the AT3-III E from service and secure it
against inadvertent use in such cases.
Opening of Equipment / Repair
The equipment may be opened only by authorized
service personnel to ensure the safe and correct
operation of the equipment and to keep the
warranty valid.
Even original spare parts may be installed only by
authorized service personnel.
In case the equipment was opened by unauthorized
personnel, no warranty regarding personal safety,
measurement accuracy, conformity with applicable
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gossen Metrawatt AT3-III E bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gossen Metrawatt AT3-III E in de taal/talen: Engels als bijlage per email.

De handleiding is 0.59 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info