479861
4
Verklein
Vergroot
Pagina terug
1/12
Pagina verder
ACTIVATING THE ALARM SYSTEM.
The alarm can be activated by pressing key no.1 on the remote or by inserting the electronic key into
the appropriate socket. The operation is confirmed by a visible signal consisting of one flash of the turn
indicators lasting approximately one second. While the visible signals are being emitted, the following
functions are enabled:
a) Module output (PINK wire / +A)
b) LED output (lit continuously to indicate neutral activation time)
c) Engine blocks
d) Activation of door-locking control (with the timing selected at programming phase).
If the electronic key is used, all the functions described under points a), b) and c) will be activated,
whereas d) ACTIVATION OF DOOR-LOCKING CONTROL will not occur (enabling the user to get out
of the vehicle).
Moreover, by using the electronic key, a car entry time of approximately 10 seconds will be generated
to allow the user to get into the car and deactivate the alarm system with the electronic key without
creating a fals e alarm.
While the user gets into the car, entry time is indicated by the continuous light of the LED.
NEUTRAL ACTIVATION TIME CUTTING OUT THE EXTERNAL SENSORS / STOPPING WINDOW UPWARD TRAVEL /
COMFORT.
Neutral activation time lasts approx. 35” and it is indicated by the continuous light of the LED. This time
interval allows the user to get out of the vehicle without causing false alarm conditions. During the first
25” of the neutral time, it is possible to cut out the external sensors and stop the windows’ upward
travel by pressing key no. 2 on the remote (Note: the stop window function requires the installation of a
special module see art. 2344 – or the existence of the COMFORT function in the car).
THE ACTIVATION OF SAI D FUNCTIONS (CUTTING OUT THE EXTERNAL SENSORS / STOPPING WINDOW
UPWARD TRAVEL / COMFORT) IS INDICATED BY A BRIEF FLASH OF THE TURN INDICATORS.
NOTE: SENSOR CUTOUT IS LIMITED TO A SINGLE AL ARM ACTIVATION CYCLE.
CUTTING OUT THE SIREN .
To cut out the sound of the siren and enable the alarm signal only through the turn indicators you must
follow this procedure:
a) With the system off, turn the ignition key to the ON position the LED will light up for about 0.5
seconds.
b) While the LED is ON (0.5 seconds), press key no.2 on the remote the LED will immediately go
out.
The siren, including the supplementary external siren or the original horns, will be cut out during the
next alarm activation cycle. To reactivate the siren, just deactivate and reactivate the alarm system.
SYSTEM READY AFTER NEUTRAL TIME.
At the end of the neutral time (approx. 45”), the security system is completely armed and ready to
intervene in cases of attempted theft or sabotage.
Completely armed status is indicated by the flashing of the LED, which will wok according to the
following timing scheme in order to minimise power consumption:
LED ON : 200MS
LED OFF : 2”
EVENTS THAT CAN GENER ATE AN ALARM CONDITION:
a) SYSTEM WIRE CUTTING BY MEANS OF THE SELF -POWERED SIREN .
b) ATTEMPT TO START THE ENGINE.
c) POWER DRAINED. (THIS FUNCTION IS ACTIVE ONLY IF ENABLED IN THE ACCESSORY FUNCTION
PROGRAMMING PHASE AND CAN BE USED ONLY IN COUNTRIES WHERE THE LAW DOES NOT PROHIBIT THE
USE OF THIS SENSOR ).
d) ATTEMPT TO OPEN THE DOORS
e) ATTEMPT TO OPEN BOOT.
f) ATTEMPT TO OPEN ENGINE BONNET.
g) INTRUSION DETECTED BY INTERNAL ULTRASOUND VOLUME SENSOR.
h) INTRUSION DETECTED BY EXTERNAL SENSORS (OPTION) (ALSO BY RADIO ).
i) PANIC ALARM BY PRESSING KEY NO. 2 ON THE REMOTE (THIS FUNCTION IS ACTIVE ONLY IF
ENABLED IN THE ACCESSORY FUNCTION PROGRAMMING PHASE AND IT CAN BE USED ONLY IN COUNTRIES
WHERE THE LAW PERMITS THIS TYPE OF ALARM ACTIVATION NOT AVAILABLE IN PRODUCT
VERSION FOR THE DUTCH MARKET).
NOTE: In order to filter noise and/or undesired signals, the POSITIVE POLE UNDER KEY, DOORS
PUSHBUTTON and BOOT PUSHBUTTON inputs have a DEBOUNCE time of 200mS. Therefore
these inputs will cause the generation of an alarm cycle only if the signals coming in last longer than
200mS.
ALARM CYCLE.
An alarm cycle generated by an attempt to break in consists of the activation of the sirens
connected to the alarm device (unless previously cut out) and the flashing of the turn
indicators (with a timing scheme of 0.5” ON 0.5” OFF) for a maximum time period of 30”.
The supplementary siren/ original car horn output will have the following characteristics as
a function of type of programming chosen at the installation phase:
SUPPLEMENTARY SIREN OPERATION :
Continuous audible signal for the entire duration of the alarm signal cycle.
ORIGINAL HORN OPERATION :
Intermittent sound 2” ON – 2” OFF for the entire duration of the alarm signal cycle.
If the user has cut out the siren, the alarm condition will be indicated solely by the flashing of the turn
indicators for a maximum time period of 30”.
NOTE: While the alarm signal is given out, the LED will emit a continuous light.
You can cut off the alarm cycle without deactivating the system, by pressing key no. 2 on the remote.
As you do so, the audible/visible alarm signals will be immediately cut off, and the system will switch to
the condition of NEUTRAL TIME BETWEEN SUCCESSIVE ALARMS.
To minimise acoustic pollution, the DOORS PUSHBUTTON, BOOT PUSHBUTTON, BONNET
PUSHBUTTON, ELECTRICAL INPUT SENSOR, INTERNAL VOLUME SENSOR and EXTERNAL
SENSORS inputs are subject to a limitation of up to five alarm cycles per system activation period. The
count is reset upon the next deactivation of the alarm system or if an alarm for POSITIVE POLE
UNDER KEY intervenes during the same activation cycle,.
NOTE: THE POSITIVE POLE UNDER KEY INPUT AND THE WIRE CUT FUNCTION (BY MEANS OF THE
SELF-POWERED EXTERNAL SIREN ) HAVE NO ALARM LIMITS.
NEUTRAL TIME BETWEEN SUCCESSIVE ALARMS.
At the end of each alarm cycle there is a neutral time period, lasting up to approx. 5”, during which
there will be no reaction to the causes of alarm. During the neutral time between successive alarms,
the LED will emit a continuous light. Normal flashing will be resumed at the end of the neutral time.
DEACTIVATING THE ALAR M SYSTEM.
The alarm system can be deactivated by pressing key no.1 on the remote, or by inserting the
electronic key into the appropriate socket (or by means of an emergency PIN-CODE procedure during
the neutral time between successive alarms).
Following this action, the centralized door-unlocking command will be implemented at once, according
to the timing programmed at the installation phase, and two different types of confirmation signals will
be generated:
1) DEACTIVATION WITHOUT ANY ALARM CONDITION BEING INDICATED: If no theft or break-in
attempts have been detected during the surveillance period, the system will give out a visible
signal consisting of three flashes of the turn indicators.
2) DEACTIVATION WITH INDICATION OF ALARM CONDITIONS: If one or more attempted thefts or
break-ins have been detected during the surveillance period, the system will give out a visible
signal consisting of 5 flashes of the turn indicators.
WHEN THE ALARM SYSTEM IS DEACTIVATED, THE FOLLOWING OUTPUTS / FUNCTIONS ARE DISABLED :
a) EXTERNAL SELF-POWERED SIREN
b) MODULE OUTPUT (PINK wire / +A)
c) LED OUTPUT
d) ENGINE BLOCK function
4

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Gemini-7590

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gemini 7590 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gemini 7590 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,36 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info