Instructions for Assembly and Use
TCS-Cody 3
Electronic encoder-type lock
The TCS-Cody is a modern and safe alternative to traditional key switches.
The TCS-Cody can safely be used after two simple programming steps (master
code and pass code). For opening or closing of the door only a four- or five-digit
numeral code (pass code) has to be entered, which has been previously program-
med via the master code by an authorized person.
After correct input of the pass code and actuation of arrow keys UP
or DOWN
the drive (UP or DOWN) is triggered by the corresponding relay contact.
The high flexibility of the encoder is achieved by extensive programmability of the
individual operating functions. All sections required for operation are, however, pre-
programmed and thus immediately ready for use.
Technical Data:
24 V series 230 V series
Supply voltage 12 - 24 V AC / DC 230 V AC 50 Hz
Output 3x NO, NC relay contact, 3x NO, NC relay contact,
isolated, 8 A 250 V isolated, 8 A 250 V
Connections 2.5 mm
2
max., 2.5 mm
2
max.,
Ambient- -20 ˚C to +60 ˚C -20 ˚C to +60 ˚C
temperature
Adaptation of the TCS-Cody 3 to special requirements:
The TCS-Cody 3 is provided with a series of flexible time settings which allow the adaptation
to special cases of application. For programming these special operating modes please ask
for our flow chart for the TCS-Cody series, if required!
geba GmbH is released of its obligations regarding guarantee and product liability if - without
prior permission - the unit has been modified, or if the installation is unproper or not in
accordance with our instruction manual.
The installer has to take care that the EMC-regulations are respected.
GB
The most important characteristics of the TCS-Cody are:
Simple operation, programming and assembly.
Water-protected enclosure
A maximum of safety:
The electronic decoder is separately installed in the
protected area
Up to 50 different pass codes can be stored
Up to 100 million different coding possibilities
Variable lock-out function
Nearly unlimited data security, even with power failure
Three potential-free relay outputs
After entry of a valid pass code and within 30 seconds the user can con
trol the drive unit connected in dead man‘s operation by means of arrow
keys ”UP” and ”DOWN” .
High switching capacity for direct control of appliances
industial controls
®
industial controls
®
Program 2
Clearing of a pass code
A pass code is cancelled by clearing of the corresponding memory
location (00-49)
In case of loss of the master code:
In case you forget the master code or the appliance has been accidently interfered with, there
is the possibility to reset the appliance by means of pressing the general reset button. This
means the appliance is brought back into the state preset by the factory.
Now the master code 12345678 preset by the factory as well as the pass code 1234 are valid
again. The appliance must now be re-programmed again.
Input 8-digit
master
code
Input of 2-digit
memory location,
e.g. 07 or 28
Sound
signal
2 x long
Sound
signal
1 x short
Sound
signal
1 x long
Push key
button
Push key
button
Push key
button
The memory location chosen is now cleared
Push key
button
2
Dear customer,
The Cody which you have purchased is one of our highest quality technical pro-
ducts. We have taken the greatest care in its manufacture to ensure that this
microprocessor controlled encoder reaches you in faultless condition. However in
the unusual event of suspected equipment failure please return the appliance
together with the enclosed warranty document to your dealer or direct to our
factory.
The extent of warranty exclusively refers to the free repair of malfunctions of the
appliance, which demonstrably are caused by faults in production or defective
material, inclusive of spare parts required for this purpose.
Therefore please first read the instructions of use carefully before you start
programming!!!
WARRANTY-DOCUMENT
On the below described encoder we grant a warranty of
1 year
Type: TCS - Cody 3
Serial number: see label on logic PCB
Serial master code: All appliances are supplied with master code 12345678
Pass code: All appliances are supplied with pass code 1234 on memory location 01
Production date: ____________________________________________________
Sales date: ____________________________________________________
Dealers adress:
Reset to factory-settings:
Hold the GENERAL RESET BUTTON - after several short
sound signals a long sound signal can be heard (~ 5 sec.).
industial controls
®
industial controls
®
Description of the appliance
The TCS-Cody consists of a decoder and a keyboard. The units are connected by a simple
double-wire cable without a special plug. Programming of the TCS-Cody is possible with the
keyboard and the master code.
Attendance/Function:
The TCS-Cody 3 has three potential free relay-outputs enabling direct control of a tubular
drive or an industrial door drive unit or similar instruments. After having entered a valid pass
code the user can, within a period of 30 seconds, trigger the installed drive unit in the dead
man’s mode with the arrow-keys “UP“ and “DOWN“ . The relay is activated only as long
as the arrow-keys are pushed. The two relays are interlocked against each other, so it is not
possible that both relays can be attracted at the same time. After expiration of the enable
time of 30 seconds the TCS-Cody locks automatically. The appliance can, however, also be
blocked intentionally within the enable time by pushing the “STOP“ key. The enable time is
freely programmable and can be changed according to the individual demands, if required.
Master
code:
The master code is an 8-digit numeral code necessary for all programming procedures.
Only after the input of this code the appliance can be programmed according to your
personal needs. TCS-Cody is preset by the company with the master code 12345678.
Pass
code:
The pass code is by choice a four- or five-digit numeral code, by which you operate your
door drive unit. You have the possibility to store up to 50 different pass codes, which means
that up to 50 different persons with different pass codes can open the door. In case you
are accompanied by another person when entering your pass code you can at first press
as many keys as you like before you finally enter your code. This ensures that no other
person can notice your pass code, but the TCS-Cody recognizes your pass code as
correct! The TCS-Cody is preset by the company with the pass code 1234 on memory
location 01.
ATTENTION!!!
After you have made yourself familiar with the functions of the appli
ance, please program your personal master code as well as a pass
code with which you replace the pass code which is located on the
memory place 01. Only by this your TCS-Cody is protected against
manipulation!
Lock-out
function:
If the lock-out function is actuated the TCS-Cody automatically blocks for 10 seconds
after the input of a wrong pass code which is signalled with a double sound signal.
By choice, you can arrange that the lock-out time can be doubled after any wrong input
until a correct pass- or master code is entered. The end of the blocking time is signalled
by a long sound signal.
Program 2
Input / Clearing of a pass code
Input 8-digit
master code
Input 4- or 5-digit
pass code
Sound
signal
2 x long
Push key
button
Push key
button
Input of 2-digit
memory location
e.g. 07 or 28
Sound signal
1 x long
Sound signal
1 x short
Push key
button
The pass code entered is now stored at the memory
location selected and connected to the fixed output !
With this procedure you can allocate 50 different
pass codes to the memory locations 00-49 !!
2
industial controls
®
industial controls
®
Please read first - then do programming!!!
Before programming your TCS-Cody with your personal codes, please check the faultless
function of the appliance with the help of the factory‘s pass code 1234 and the key-operated
pushbutton.
Normally, any programming is made via your personal master code. In order to get familiar
with that kind of programming, you start with the input of a new pass code, which replaces
the one preset by the factory (1234). The procedure is explained under item
“Program2“.
After that please change the master code to the string of digits you choose.
ATTENTION
In case you made a mistake on programming, you can start again by actuation of the key-
operated pushbutton (`*`).
Program 1
Input of a new master code
Assembly Instructions
Assembly of the CODY keyboard:
1. By slightly pushing the two latches at the right and left side of the keyboard
from behind to the edge, remove the small frame from the keyboard.
2. Now you see two fixingholes (diam. = 4 mm) at the front of the keyboard.
By means of these you can fix the keyboard onto the wall.
3. Connect the keyboard to the logic unit by means of a twin-cable (up to 5 m long).
There is no particular polarity for the twin wires.
4. Now re-fix the small frame.
5. It is possible to connect in parallel up to four keyboards if a thin connection cable, max.
total line cross-section 1.5 mm
2
, is used.
Keyboards connected in this way must not be operated simultaneously.
Assembly of the logic unit (inside area):
1. Put the screw-driver into the gap of the enclosure front, push the screw-driver up and
open the enclosure.
2. Remove the control PCB (which is force fitted to the inside of the enclosure).
3. Locate the screwed glands supplied (sealing nipple left side) in the
enclosure and replace the PCB. (Please ensure PCB is firmly in position)
4. Bore the fastening holes and fix the enclosure bracket at the wall.
5. The wires for the keyboard ensure through the left cable entry (sealing nipple), the wires
for the relay contacts through the three middle cable entries and the wires for the supply
voltage ensure through the right cable entry. Ensure tight seating of sealing nipple and
cable gland, otherwise the water-protection ot the appliance cannot be assured.
6. According to connection diagram connect the wires to the corresponding terminals.
Connections: Keyboard, UP - control, DOWN - control, STOP - control,
Supply voltage
Programming Instructions
Spannungs-
versorgung
Tastatur
Trafo
Industrietor
Antrieb
Netz 3x400 V
AB
AUF
STOP
Generalreset
X N L1 N PE PE
Connection diagram:
Input 8-digit
master code
Input 8-digit
NEW master code
Sound
signal
2 x long
Push key
button
Push key
button
Sound signal
1 x long
Sound signal
1 x short
Push key
button
The new master code is now stored !
1
Motor reversing by interchanging of connection wires UP (black) and DOWN (brown).
keyboard
GENERAL RESET
Push Button
power supply
power supply
400 V
Industrial door
drive
UP
DOWN
STOP
Trans-
former
industial controls
®
industial controls
®
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Geba Tronic TCS-Cody 3 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Geba Tronic TCS-Cody 3 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,16 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Geba Tronic TCS-Cody 3

Geba Tronic TCS-Cody 3 Gebruiksaanwijzing - Nederlands - 4 pagina's

Geba Tronic TCS-Cody 3 Gebruiksaanwijzing - Deutsch - 4 pagina's

Geba Tronic TCS-Cody 3 Gebruiksaanwijzing - Français - 4 pagina's

Geba Tronic TCS-Cody 3 Gebruiksaanwijzing - Espanõl - 4 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info