22
Nozzle Replacement
Changing over to a different gas type
Only authorised specialists are permitted to
change over to a different gas type.
The nozzles needed for the gas type to be set
are available as a conversion kit. Please specify the
appliance type and the required gas type.
The nozzles can be changed on the installed
appliance.
Loads for all gases
For all gas types and pressures, the rated load
is achieved by installing the high and low setting
nozzles for the required gas type (see nozzle
table).
Replacing the low setting nozzles
• Switch off the power at fuse point and close the
gas supply!
• Detach pod grid, burner ring, burner head cover
and burner head.
• Undo trough securing nuts and carefully detach
the trough. Loosen the nuts of the spindle cover
and remove cover.
• Detach the spindle between the control knob and
the gas tap.
• Turn the black plastic part so that the recess is
above the nozzle. Screw out nozzle and take
nozzle out with small pliers.
• Replace both low setting nozzles on the gas taps
according to the new gas type and as detailed in
the low setting nozzle table. Fully screw in the
new low setting nozzles.
Important: be careful not to damage the O-ring.
See table on page 15
for details of nozzle settings.
outer low
setting nozzle
inner low
setting
nozzle