25
Technical Data
Total connected load: 8680 W
Important notes on installation
Pay attention to the "Important notes" on page
3 and 4.
The appliance must only be connected by an
authorised specialist, paying attention to the
relevant regulations of the power supply companies
and the regional construction regulations.
The installation technician is responsible for the
correct functioning of the appliance at the place of
installation. He must instruct the user on how to
disconnect the appliance from electricity in an
emergency.
If the range is not installed over a built-in cooker,
protection against hazardous contact from below
must be ensured after assembly, e.g. by installing
an intermediate shelf that can only be detached
using a tool. The distance between the interme-
diate shelf and the worktop in which the range is
recessed must be at least 60 mm.
There must be a gap of at least 20 mm at each side
between the appliance and any flammable walls or
furnishings.
If all poles of the appliances cannot be isolated
from the mains by removing an accessible plug, an
isolating device with a contact gap of at least 3 mm
must be installed (e.g. domestic fuse).
No warranty claims can be lodged for any
damage resulting from failure to observe these
instructions.
Subject to technical change without notice.
Electrical connection
The appliance must only be connected by an
authorised specialist.
All corresponding regulations must be observed.
The mains connecting cable must at least
correspond to type H 05 VV-F.
Note for single phase connection:
This device is intended for the connection to a
power supply system with a maximum permissible
system impedance Z
max
of 0.46 Ohm at the interface
point (power service box) of the user’s supply.
The user has to ensure that this device is
connected only to a power supply system which
fulfills the requirement above. If necessary, the user
can the ask the public power supply company for
the system impedance at the interface point.
Pay attention to the data on the rating plate. The
appliance must be properly grounded. Connect the
connecting cable to the mains.
When connecting electrical appliances in the
proximity of cooking surfaces, make sure that
connecting cables do not come into contact with hot
cooking surfaces.
This appliance may be installed in kitchen
combinations made of wood or similar combustible
materials without taking additional measures.
The built-in furniture and worktop where the
appliance is installed must be heat resistant up to
temperatures of 200° F/90° C.
10. Installation