INSTALLATION
20 SA5
TESTING THE SYSTEM
INITIAL TESTING
As the system is initially installed it is recommended
that each device is tested in turn as it is installed, (refer
to testing instructions for particular device).
TESTING AN INSTALLED SYSTEM
The Control Panel has a built in test facility to enable
you to test the system at any time. However it is
recommended that the system is tested at regular
intervals not exceeding 3 months.
With the system in Standby Mode
Press , ,
The Arm and Part-Arm LEDs will flash.
The system is now in the Test Mode
Use the and buttons to scroll through
the menu and press to select the displayed test
function or sub-menu.
Note: After completing all required test functions
press to leave Test mode and return to Standby.
WALK TEST
Before commencing testing please ensure that there
is no movement in any PIR protected area, all
doors/windows protected by Magnetic Contact
Detectors are closed and that all battery covers and
housings are correctly fitted.
Scroll through the top level Test Mode menu until
‘WALK TEST’ is displayed and press .
‘Walk Test Waiting…’ will be displayed.
1
.Trigger each detector on the system by either
walking into a PIR protected area or by opening a
door/window protected by a Magnetic Contact
detector. As each detector is triggered the Control
Panel will beep to indicate that an alarm signal has
been received and the identity of the zone that the
detector is configured for will be displayed.
Note: To conserve power and maximise battery
life the PIR detector will only detect movement if
there has been no movement detected within the
previous 2 minutes.
2
. Operate detector anti-tamper switches by opening
the case of the device. As the switches are
then remove the DC power jack and disconnect one of
the back-up batteries.
The hardwired zone and tamper switches should be
Volt free and Normally Closed, with the contacts
opening in order to initiate an alarm.
Note: Jumper link P51 should be fitted into the ON
position only if the external hardwired tamper circuit is
used, otherwise it must be in the OFF position.
After making your external connections reconnect the
power supply and Back-up Battery. Then close the
Control Panel cover and tighten the fixing screws on
the top edge of the Control Panel.
Press to leave Test mode and return to
Standby.