74
Full Alarm sounds when system has not
been triggered by an intruder or is disarmed.
1. Tamper switch activation
a. Check all detector battery covers to ensure
correctly fitted.
b. Check Control Panel and Siren are securely
mounted to the wall and Tamper switch is closed.
2. Personal Attack Alarm operated from a Remote
Control or Control Panel.
3. Jamming Detection circuit operated.
LED on Remote Control not illuminating, or
is dim when unit is operated.
1. Ensure battery is fitted with correct polarity.
2. Ensure battery holder connections are making
good contact with the battery.
3. Battery flat - replace battery.
PIR Detector false alarming.
1. Ensure that the detector is not pointing at a source
of heat or a moving object.
2. Ensure that the detector is not mounted above a
radiator or heater.
3. Ensure that the detector is not facing a window or
in direct sunlight.
4. Ensure that the detector is not in a draughty area.
5. Sensitivity set too HIGH - reset to LOW sensitivity.
(i.e. SW3 to down position).
PIR Detector not detecting a person’s
movement.
1. Ensure the battery clip is securely connected.
2. Ensure ‘ID Code’ of the detector is learnt for a
particular zone.
3. Sensitivity set too LOW - reset to HIGH sensitivity.
(i.e. SW3 to up position).
4. Ensure that detector is mounted the correct way
up, (i.e. with detection window at the bottom).
5. Ensure that the detector is mounted at the correct
height, (i.e. 2- 2.5 metres).
6. Allow up to 3 minutes for detector to stabilize and
become fully operational. Leave the area for this
period.
7. Ensure detector is within effective radio range of
the Control Panel and is not mounted close to metal
objects which may interfere with Radio transmission.
PIR Detector LED flashes on detection of
movement, (device in normal operation
mode).
1. PIR still in Walk Test Mode for fixed 5 minutes
after the PCB button was activated.
2. Low battery - replace battery.
Door Contact not working.
1. Ensure that Magnet is correctly positioned in
relation to Detector and that the gap between Magnet
and Detector is less than 10mm.
2. Ensure batteries are fitted with correct polarity
(correct way around).
3. Ensure battery holder connections are making
good contact with the batteries and Circuit Board.
4. Ensure ‘ID Code’ of the detector is learnt for a
particular zone.