When operating the appliance
• If you are going to use the hot air gun, vapours and gas can be liberated during a short time.
This can be harmful for your health. Asthmatics can suffer hindrance of it;
• Before connecting the plug to the mains voltage you have to check if the switch is in
position “0”;
• Keep the mains lead always away from the mouthpiece of the hot air gun;
• Keep children and animals away from the appliance if you are using it.
Immediately switch off the appliance when:
• Plug and/or cable are defective or damaged;
• The switch is defective;
• You smell or see smoke caused by scorched insulation from the hot air gun.
3. USING THE APPLIANCE
The Hot air gun can be used for:
• Plumbing work like tube connections, solder, bowing tubes;
• Removing paint, varnish and lacquer without firerisk;
• Quickly drying of appliances which have become wet;
• Drying surfaces for quick repairing;
• Removing self-adhesive labels in a clean way placing PVC labels;
• Blistering after sticking PVC materials can be smoothed after heating;
• Easy removing of vinyl carpeting:
• Forming all synthetics with a low temperature (350 degrees) among which polyethylene
and PVC;
• Forming all synthetics with a high temperature (580 degrees) among which acryl and
plexiglass;
• Smelting synthetics, among which matters and foils with PVC layer;
• Applying heat shrinking tubes;
• Shrinkwrappers;
• Thawing tubes and engines;
• Repairing finishing layers: email of bath and household appliances;
• Applying epoxypowder coverlayers;
• Repairing of ski’s, surf-boards and other sports goods;
• Unscrewing too fast fixed screws and connections.
Before operating
Before you switch on the hot air gun you have to search for the right adapter for the mouthpiece
and assemble it on the mouthpiece if it is still cold.
Replace the mouthpiece only:
• With a stationary engine.
• When the appliance is disconnected;
• When the mouth piece is cold.
GB