Use
The hood has been made for use in the internal recirculating
filtering version.
Cooking fumes and steam are aspirated inside the hood,
filtered and cleaned, passing through the fat filter/s and the
carbon filter/s that MUST be supplied with the hood.
Important
It is possible to buy an extraction operation Kit.
In this case the charcoal filter must not be installed.
Furthermore, the use of the extraction kit may require a
different installation of the hood from what shown in this
manual; therefore, before starting the installation of the hood,
buy the extraction kit and consult the instructions enclosed
with the kit.
Installation
Specialised personnel must carry out both the electrical
and the mechanical installation.
The minimum distance between the supporting surface for the
cooking equipment on the hob and the lowest part of the
range hood must be not less than 50cm from electric cookers
and 65cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
Electrical connection
The mains tension must correspond to the tension shown on
the characteristic label situated inside the hood.
The product is meant for connecting directly to the mains
supply, therefore apply a regulation bipolar switch that
ensures complete disconnection from the mains in the
conditions of category III over-tension, conforming to the
installation rules.
Warning! Detail B (fixing bracket to the ceiling) is
equipped with a conductor (yellow-green) that must be
connected to the earth of the domestic electrical plant.
Fig. 16-17
ATTENTION! Be particularly careful about positioning
the excess cable. Failure to observe this indication could
cause grave damage to the apparatus and/or an electric
shock to the user or the installer.
Warining! Changing the interconnection cable must be
carried out by the authorised technical assistance service.
Mounting
Before beginning installation:
Check that the product purchased is of a suitable size for
the chosen installation area.
Remove the charcoal (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
Attention! Before connecting the hood to the electrical
mains.
If you have an Elica hob:
Perform the electrical connections of the hood and Elica
hob at the same time to ensure the logical connection
between the hob and Elica hob (also refer to the
paragraph "Operation-Adjusting the parameters for
automatic operation-Sensor calibration" e
"Operation-Adjusting the parameters for automatic
operation-Logical connection between hood and
Elica hob").
If you do NOT have an Elica hob:
In this case, after being connected to the mains, the hood
will try connecting to a hob.
Wait for the hob to complete the connection attempts
(approximately 5 minutes) and then disable the electronic
connection module as follows:
With the hob switched off, simultaneously press and hold
keys T1 and T2 for 10 seconds, (see Operation
paragraph), the hood at first emits a short sound signal
(beep- after approximately 5 seconds), followed by a long
sound signal (beeeep), indicating that the disabling
process is complete (LED L1 turns red for a few
seconds).
Reactivating the connection module between the
hood and Elica hob: With the hob switched off,
simultaneously press and hold keys T1 and T2 for 10
seconds, (see Operation paragraph), the hood at first
emits a short sound signal (beep- after approximately 5
seconds), followed by a long sound signal (beeeep),
indicating that the activation process is complete (LED L1
turns red for a few seconds).
This type of cooker hood must be fixed to the ceiling.
Very heavy product; hood handling and installation must
be carried out by at least two persons.
Expansion wall plugs are provided to secure the hood to
most types of walls/ceilings. However, a qualified technician
must verify suitability of the materials in accordance with the
type of wall/ceiling. The wall/ceiling must be strong enough to
take the weight of the hood. Do not tile, grout or silicone
this appliance to the wall. Surface mounting only.
37

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Elica Audrey Sense bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Elica Audrey Sense in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Deens, Zweeds, Noors, Fins als bijlage per email.

De handleiding is 11,71 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info