753497
17
Verklein
Vergroot
Pagina terug
1/60
Pagina verder
17
ENGLISH
Caution!
Check all connections and
supply lines before switching ON.
Caution!
At the workplace, secure the
machine against rolling away.
8.1 Control unit
The operating parameters are set and
displayed at the control unit.
With the pushbutton for parameter
selection, the parameter to be displayed
or adjusted is selected.
The following parameters can be
selected and displayed:
Wire feed [m/min]
Welding current [A]
Welding voltage [V]
Arc length [%]
The selected parameter is indicated by
the LEDs and its value is displayed on
the 7-segment display.
Using the parameter adjustment the
desired value, except the welding volt-
age, is set.
Wire feed
Via the parameter wire feed the feed
speed of the wire feed drive is set. The
best value for welding voltage and weld-
ing current is computed by the machine,
dependent on the selected charateristics
curve.
wire feed value range:
1.5 ... 19 m/min.
The value range available for adjustment
is dependent on the selected electrode
wire and the operating mode.
For manual arc welding the display is
disabled.
Welding current
The best current strength is determined
by the machine. During MIG/MAG weld-
ing the welding current can not be
adjusted. The set value can be adjusted
prior to welding via the parameter adjust-
ment.
For manual arc welding it is possible to
adjust the set value of the welding cur-
rent before the welding starts and also
during the welding process (actual
value).
Welding voltage
The welding voltage is displayed only. It
can not be adjusted.
Arc length
In MIG/MAG and pulsed MIG/MAG oper-
ating mode, the value set affects welding
voltage.
The adjustment range is from 50%
through 150%. 100% is the best operat-
ing point.
Note:
When using interconnecting torch
lead extensions, the occuring voltage
drop can be compensated by the param-
eter. In this case adjust to values of
110% ... 120%.
8.2 Gas-shielded arc welding
Caution!
Check before starting any
work:
Correct electrode wire installed?
Correct shielding gas connected?
Welding gun correctly fitted
(liner, spiral liner, contact tip, gas
shroud, support tube)?
1. Attach earth cable at suitable loca-
tion of workpiece.
2. Open cylinder valve and set desired
gas flow rate.
Change gas shroud, if necessary.
3. Set main switch at Powerbox and
mains switch of SWK to ON.
4. Adjust the machine’s default setting.
Selet charateristics curve.
5. Change parameters, if required.
The welding machine is now opera-
ble.
8.3 Manual arc welding
1. Attach earth cable at suitable loca-
tion of workpiece.
2. Set main switch of Powerbox to ON.
3. Select welding process ELE-
KTRODE.
The welding machine is now opera-
ble.
8.4 Shutting down
1. Close gas cylinder valve.
2. Set main switch to "0".
3. Disconnect earth cable from the
workpiece.
4. Unplug power cable.
This welding machine contains no user-
serviceable parts.
Depending on dust accumulation, the
Powerbox and the SDV should be blown
out with condensate-free compressed
air.
Periodically check all components for
visible damage.
Contact a qualified electrician if any of
the cables are damaged.
For models 232/ 302/ 402/ 502 EP the
accessories mentioned below are rec-
ommended. These accessories have
been tested with the machine and
ensure operation without any problem.
AWelding guns for 232 EP
1) SB 24/3
2) SB 24/4
3) SB 24/5
BWelding guns for 302 EP
1) SB 36/3
2) SB 36/4
3) SB 36/5
CWelding gun for 402 EP and
232/302 EP with water cooling
1) SB 41/W3
2) SB 41/W4
3) SB 41/W5
DWelding guns for 502 EP
1) SB 51/W3
2) SB 51/W4
3) SB 51/W5
EEarth cable
1) 5 m, 25 mm2 for 232 EP
2) 5 m, 50 mm2 (copper jaws)
for 302/ 402 EP
3) 5 m, 70 mm2 (copper jaws)
for 502 EP
FInterconnecting torch lead exten-
sion
for 232/302 EP
1) 5 m, 50 mm2, gas-cooled
2) 10 m, 50 mm2, gas-cooled
GInterconnecting torch lead exten-
sion for 232/302/402 EP with water
cooling
1) 5 m, 50 mm2, water-cooled
2) 10 m, 50 mm2, water-cooled
HInterconnecting torch lead exten-
sion
for 402/502 EP
1) 5 m, 70 mm2, water-cooled
2) 10 m, 70 mm2, water-cooled
IPressure gauge with 2 gauges and
stop valve.
8. Operation
Shielding gas amount in l/min Aluminium Steel
Welding current in A
Gas shroud diameter
in mm
9. Maintenance
10. Available Accessories
17

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Elektra Beckum Mig Mag 232EP bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Elektra Beckum Mig Mag 232EP in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 3,28 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info