ENGLISH
A
B
A
B
HOT AIR CIRCULATION
ONLY for the CHANNELLED VERSION
The stove is equipped with a rear outlet (see positioning
on page 25) for the air to be channelled into the adjacent
room by means of the specific optional Kit 8 (code
297360), which consists of:
• clamp fitting
• flexible pipe Ø 10 length 1.5 m
• outlet
Please remember that it is extremely important to insu-
late the hot air pipe appropriately in order to prevent
dispersion.
Bends in the pipe must be avoided as much as possible.
The intensity of the channelled air can be adjusted
manually (see page 34). This means that the air can be
either directed to the lower front part or to the rear
(reference figure 2 page 30).
NOTE
The basic version can be upgraded to a channelled ver-
sion and to do so please contact your authorised
Edilkamin DEALER to buy the kit required (code
633430). This must be installed and connected inside
the stove.
In the NON-CHANNELLED basic version, the hot
air is emitted from the right half of the upper front
grille and the left half of the lower front grille.
A: insulated steel chimney flue.
B: minimum height 1.5 m.
C-E: room air inlet (minimum internal
cross-section 80 cm²).
D: steel chimney flue inside existing masonry
chimney flue.
Fig. 2Fig. 1
I
N
L
INSTALLATION
TYPICAL EXAMPLES
30