Technical Specifications
ELECTRICAL SPECIFICATIONS
Power supply 230Vac +/- 10% 50 Hz
On/off switch yes
Average power consumed 100 W
Power consumed upon ignition 400 W
Remote control frequency infrared
Main power supply protection *** Fuse 2A, 250 V AC 5x20
Electronic control board
protection
Fuse 2A, 250 V AC 5x20
THERMOCOUPLE:
placed on the smoke exhaust pipe to detect the temperature.
It controls the ignition, operation and shutdown
phases according to the parameters set.
AIR FLOW SENSOR:
placed in the air inlet channel.
This intervenes if an anomaly is detected in the combustion air
flow and causes insufficient circulation in the smoke ducts.
SAFETY THERMOSTAT:
intervenes when the temperature within the stove is too high
by stopping the pellets from being loaded, which in turn
causes the stove to shutdown.
The above data is purely indicative.
EDILKAMIN s.p.a. reserves the right to alter the products
without prior notice in order to improve their performance.
SAFETY DEVICES
Models and dimensions
AIDA
sandstone
MEDEA
aluminium sides with stone inserts and top
* basic/channelled
A A
B
A hot air room inlet
B hot air output for adjacent
room (channelled version)
cm 64
Hot air
channel
Ø 100 mm
Smoke outlet
Ø 80 mm
Combustion
air Ø 40 mm
Serial socket
Rs232 fitting
FEATURES
Hopper capacity 29 kg
Efficiency 89,2 %
Nominal Power 10 kW
Reduced power 3 kW
Smoke mass 6,1 g/s
Smoke temperature 190 °C
Emissions CO (13% 0
2
)
90 mm
Minimun draught 12 Pa
Min./max. autonomy 13/41 hours
Fuel consumption (min./max.) 0,7/2,2 kg/h
Heating capacity ** 240
m
³
AIDA weight including packaging* 310/311 kg
AIDA weight including packaging* 280/281 kg
Smoke duct diameter (male) 80 mm
Air inlet duct diameter (male) 40 mm
cm 54
cm 115
** The heatable room dimensions are calculated on the basis of pellets
with a lhv of at least 4300 kcal/kg and home insulation in compliance
with Italian law 10/91, and subsequent changes together with an expec-
ted heat output of 35 Kcal/m³ per hour. It is also important to consider
the location of the stove in the room to be heated.
N.B.
1) Bear in mind that external devices may cause interference.
2) Caution: live parts. Servicing and/or inspections must be carried out by
qualified staff.
(Before carrying out any maintenance, disconnect the device from the
mains power supply)