ENGLISH
46
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A BOILER-STOVEWITH HOT SANITARY WATER PRODUCTION USINGKIT 6
Kit 6 is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the product to be
properly installed.
NB: insulating mats must be applied so that the components of the kit are well protected from the heat radiation emitted by the boiler-
stoves.
1
2
3
4
5
6
7
C
D
F
11
12
13
B
8
9
10
A
E
KIT 6
SELECTOR FUNCTIONS
Selector: OFF Everything is switched off
Selector: MAN Driven Circulator
Valve is set
Selector: AUTO Circulator is set
Valve is set
Alarm selection No acoustic signal in the
OFF position
KIT 6 code 280600
1" Ball Valve
Thermal Relief Valve (72940)
Pressure Relief Valve (284220)
Circulator (219660)
Fittings with 1" Check Valve (284180)
¾" Male 3-way Solenoid Valve (283690)
Fittings
20-plate Heat Exchanger for hot sanitary water
production (284300)
Temperature Relief Valve Nozzle
Closed Expansion Tank (283680)
Flow Switch (220830)
½" Thermometer Well + Sensor (175960)
Electronic Regulator (220780)
3/8" Automatic Relief Valve (284150)
1/4" Manual Relief Valve (284170)
Manometer (269590)
Boiler-stoves Return
System Return
Boiler-stoves Return
Cold Sanitary Water
Pressure Relief Valve
Hot Sanitary Water
Temperature Relief Valve
14
15
16
G
NB: essential safety connections
safety valve connection
ACS:
AF:
AL:
C:
EV:
NA:
NC:
F:
GR:
Ja:
Jm:
MAN:
MI:
P:
RA:
RE:
RI:
S:
SC:
ST:
V:
Vec:
VR:
VSP:
VST:
Hot Sanitary Water
Cold Water
Water Mains Supply
Filling/Top-Up Section
3-way Solenoid Valve
Normally Open
Normally Closed
Flow Switch
Filling unit
Automatic Relief Valve
Manual Relief Valve
Manometer
System Flow
Pump (circulator)
Radiators
Electronic Regulator
System Return
Drain
Plate Exchanger
Temperature Sensor
Ball Valve
Closed Expansion Tank
Check Valve
Pressurised Safety Valve
Thermal Relief Valve