ENGLISH
44
SYSTEM FOR AN OPEN/CLOSED TANK INSTALLATION
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A BOILER-STOVETHAT PRODUCES AND STORES HOT SANITARY WATER AND HAS A WALL MOUNTED BOILER USINGIDROKIT
IDROKIT is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the product
to be properly installed.
ACS: Hot Sanitary Water
AF: Cold Water
AL: Water Mains Supply
C: Filling/Top-Up Section
CE: Electronic Panel
EV: 3-way Solenoid Valve
NA: Normally Open
NC: Normally Closed
GR: Pressure Reducer
Ja: Automatic Relief Valve
Jm: Manual Relief Valve
MI: System Flow
MT: Thermostatic Mixer
P: Pump (circulator)
RA: Radiators
RI: System Return
S: Drain
SC30: 30-plate Heat Exchanger
ST: Temperature Sensor
TC: Contact Thermostat
TM: Thermo Boiler-stoves
V: Ball Valve
Vea: Open Expansion Tank
Vec: Closed Expansion Tank
VR: Check Valve
VSPT: Safety Pressure and Temperature Valve
VCA: Boiler
IDROKIT
A
B
C
D
E
1 heating return
2 gas boiler hot sanitary water
3 boiler-stoveflow
4 drain
5 hot sanitary water
6 boiler-stovereturn
7 heating flow
8 water mains
9 thermostatic mixer setting
10 synoptic panel
11 auxiliary socket for a room thermostat
1
2
3
4
5
6
7
8
10
9
A 30-plate Heat Exchanger
B primary circulator (in the wood-fired version)
C 50-litre boiler
D heating system circulator
E closed expansion tank
F boiler-stoves covering for exposed installation
F
cm 45cm 44
cm 115
11
IDROKIT code 601740
TM
Collector
Safety pipe Ø> 28mm
Inlet pipe Ø> 18mm