15.7.3 Dometic 8 series with MES
9 The gas supply has been cut
off. The flame has not been ig-
nited within 30 seconds in gas
operation mode
z Check the gas supply
z Repeat ignition 3 to 4 times
z Contact customer service
10 The refrigerator is set to 12 V
mode and the vehicle engine
is not running
Start the vehicle engine or se-
lect a different energy source
11 The refrigerator is set to "AU-
TO" mode and no energy
source is available
Provide an energy source and
reset the refrigerator. Switch
the refrigerator off and on
again for this purpose
12 – Contact customer service
13 The temperature sensor is de-
fective
Check whether the plug is in-
serted properly above the fin
inside the refrigerator. If so:
Contact customer service
14 The connection between oper-
ating controls and control de-
vice is interrupted
Contact customer service
Z In the case of a fault the LED display fault will always light up " ".
Fault Cause Remedy
LED " " flashes No 240 V power supply Connect 240 V power sup-
ply
240 V automatic circuit
breaker has triggered
Switch on the 240 V auto-
matic circuit breaker
240 V operating voltage
too low
Have the 240 V power sup-
ply checked by an author-
ised specialist workshop
LED " " flashes Fuse on the transformer/
rectifier is defective
Replace fuse on the trans-
former/rectifier
Disconnector relay in the
transformer/rectifier is de-
fective
Contact customer service
12 V operating voltage too
low
Have the 12 V power sup-
ply checked by an author-
ised specialist workshop
LED " " flashes
Lack of gas Open regulator tap and
gas isolator tap
Connect a full gas bottle
Cobwebs or burnt residue
in the burning chamber
Remove the ventilation
grill on the outside of the
vehicle and clean the burn-
ing chamber
Error code Cause Remedy