DECOMPRESSION AIR WARNING DECOMPRESSION NITROX WARNING
VIOLATED DECOMPRESSION STOP ALARM
Failure to observe deco depth: lower depth.
Failure to observe deco depth: greater depth.
PRE DIVE
DECOMPRESSION WARNING ALARM
DEEP STOP
17
LOG BOOK
DEEP STOP ON DEEP STOP OFF
INDEX
DECOMPRESSION WARNING ALARM.
Every time the time available within decompression, shown on the display by the NO DECO icon, decreases to
3 minutes, Newton warns the diver by emitting a sound alarm. In this situation, the no decompression limits are
being reached and a decompression dive is required.
DEEP STOP.
In order to avoid the risks related to the micro bubbles formed during the ascent, Newton is able to suggest a
DEEP STOP of one or two minutes (in case of decompression dives) at variable depth depending on the dive
profile. During the dive, if the profile requires it, DEEP STOP is displayed and an acoustic signal is issued. The
stop icon with the depth and the time minutes is displayed. In case the dive omits the Deep Stop, the warnings
will be deleted and the computer recalculates the ascent planning without that stop.
REMARK: Verify that the deep stop is enabled (see paragraph DIVE SET)
REMARK: In this case, the maximum depth can be displayed by pressing the UP or DOWN button.
DIVING OUTSIDE THE NO DECOMPRESSION LIMITS
DANGER: do not use this device to dive beyond the no decompression limits! Cressi discourages the
use of this device for decompression dives.
However, if during the dive, due to negligence or emergency, you have exceeded the no decompression limits,
Newton will provide specific information related to a correct ascent and to the decompression information.
Upon violating the limits, the computer will issue an audible alarm and the screen on the display will change to
look as indicated in the following picture providing the diver with the following information:
1) Stop icon with the text DEC at the bottom of the display indicates that the diver has gone outside the
safety curve, and must make decompression stops. The arrow pointing upward will flash to indicate the
need for ascent.
2) Depth of first decompression stage (the deepest), indicated in metres (m) or feet (ft). This can vary from a
maximum of 24 m to a minimum of 3 m by steps of 3 m in 3 minutes.
3) Duration in minutes for the first decompression stage (the deepest).
4) TOTAL icon, indicating the total ascent time, that is the time required to ascend to the deepest stage,
respecting the ascent rate, plus the stop time at that depth and any other subsequent stop (indicating the deep
stop if necessary), plus the safety stop time, plus the time required to reach the surface after completing the
decompression stages.
5) “DIVE.T” icon giving the total time spent while diving.
REMARK: In this case, the maximum depth can be displayed by pressing the UP button.
REMARK: In case the deepest stage is a Deep Stop, by pressing the UP key you will see, always on the right
top corner, the depth and duration of the first stage, not Deep Stop.
DANGER: NEVER ascend above a decompression depth.
To avoid this situation, you should ascend at a depth slightly below the recommended decompression stop
depth, but still within the depth range established for decompression and identified by the instrument with the
two icons which are simultaneously lit but not flashing. Please remember that under these conditions, the
amount of air you need to complete your dive increases.
Omitted decompression stage alarm.
If, by any reason, the decompression stage is "forced" by surfacing above the depth given by the computer, an
alarm will sound and the down arrow of the decompression icon will flash on the display until the diver
descends back to the proper depth or below it. The computer allows a maximum time of 2 minutes to correct
this dangerous situation, clearly marked by a continuous acoustic alarm.
After 2 minutes without the diver descending to the proper depth, Newton enters in the ERROR PROGRAM
making the “STOP” icon flash. It will not be possible to use the device for the subsequent 48 hours. The only
function working will be the clock and it will be possible to access the Logbook and History Later, in the PRE
DIVE screen the "STOP“ icon will start flashing, together with the word DECO and the stop icon with the arrow
up flashing. This means that the decompression stage was omitted during the last dive. The LOG BOOK will
store the same warning, indicating that on a specific date, the dive with a specific number was carried out
without the decompression stage.
DANGER: under these conditions you won't be able to dive for the next 48 hours.
In the case that you feel any symptoms of decompression sickness, you should contact the DAN (Divers Alert
Network) and your local hyperbaric chamber centre, providing as much data as possible about the dive.
In the opposite case i.e. when you descent other metre under the depth stage the arrow indicating back will
17

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Cressi NEWTON bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Cressi NEWTON in de taal/talen: Engels als bijlage per email.

De handleiding is 8,29 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info