In case of malfunctions may adjoining list of error messages help for people to get function back. Basically, electrical repairs only in compliance with the
relevant safety rules which exists. For more information and assistance in case of malfunctions with our service department (contact details see last page.)
Note:
Please contact your local dealer if you have checked all the above listed
things but the problem is still there.
Problem Potential reasons Solutions
-------Safe lock falls down1. Place back the safe lock;
2. Replace safe lock switch or magnetic sensor in the electronic meter; if the problem still fails to
be solved, replace the electronic meter;
E01After powering on, the electronic me-
ter displays E01
Communication failure from the
electronic meter to the driver, The
electronic meter displays E01 in the
operating process Communication
failure from the driver to the electro-
nic meter
1. Check whether the connecting joint between the electronic meter and the core wire of the con-
troller is loose; whether wires are damaged; whether the core wires are in correct connecting order.
2. The controller may be defective. Check and replace a good one.
3. The electronic controller’s IC may not be plugged to the place. Check and ensure good plugging.
4. The transformer may be damaged. Check and replace a good one.
E02Explosion-proof protection or motor
abnormality
1. Check whether the power supply voltage is less than 50% of the normal value; please ensure
correct voltage and test again;
2 Check whether motor wires are well connected; re-connect motor wires, or, if the problem still
fails to be solved, replace the motor;
3. Check whether there is peculiar odor generated by the controller; if yes, it means that IGBT has
been broken down to cause short circuit; then, replace the controller.
E03No sensory signal Check whether the photoelectric sensor directs to the hole on CD; check whether wires of photo-
electric sensor are damaged and whether terminals of the photoelectric sensor and speed termi-
nals on the controller are firmly connected.
E04Lifting learning or self-inspection
fails
1. Check whether motor signal wires are well inserted; re-insert the signal wire joint to ensure that
it is reliable;
2. Check whether lifting motor‘s AC wires are properly connected; lifting motor shall be correctly
plugged according to marks on its AC controller;
3. Check whether motor wiring is damaged to form open circuit; if yes, replace wires or replace the
lifting motor;
4. Replace the controller;
5. After all of these inspections, press the learning key for learning again.
E05Over-current protection 1. It may be the system’s self-protection against excessive current when the load exceeds the rated
value; restart the machine;
2. Some part of the treadmill is jammed so that the motor can not rotate, thus triggering the self-
protection of the system against excessive current under excessive load; adjust the treadmill and
restart it, or add lubricant.
3. Check whether there is over-current sound or burning odor when the motor is running; replace
the motor;
4. Check whether the controller emits the odor of burning; if yes, replace the controller.
E06Lifting sensor has no signal1. Check whether lifting signal wires are damaged.
2. Check whether lifting signal terminals and the controller’s lifting terminals are firmly connected.
3. Check whether lifting power cords are damaged.
4. Check whether lifting power cord terminals and the controller’s lifting terminals are firmly con-
nected.
No display
on the elec-
tronic meter
The controller is not powered on or
is damaged
1. First of all, check whether the over-load protector has tripped off; if yes, press it;
2. Check the power supply switch, over-load protector and the controller’s power cord and trans-
former to ensure well connection;
3. Check whether the power cords from the electronic meter to the controller are well collected;
dismantle the pillar to check connecting joints on each section of the wiring from the electronic me-
ter to the controller; ensure that each wire core is well connected; or the reason may be the com-
munication power cord defect (damaged or broke down); in such case, re-connect or replace wires.
4. The transformer is damaged; replace the transformer
E09Controller is in tilt position1. When treadmill has incline position no start possible
2. Treadmill is not fold out complete on an even floor
Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.
Product:
Spelregels forum
Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:
lees eerst de handleiding door;
controleer of uw vraag al eerder door iemand anders is gesteld;
probeer uw vraag zo duidelijk mogelijk te stellen;
heeft u een probleem en al geprobeerd om dit op te lossen, vermeld dit erbij aub;
heeft u een oplossing gekregen van een bezoeker dan horen wij dat graag in dit forum;
wilt u een reactie geven op een vraag of antwoord, gebruik dan niet dit formulier maar klik op de knop 'reageer op deze vraag';
uw vraag wordt direct op de website gezet; vermijd daarom persoonlijke gegevens in te vullen;
Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.
Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.
Abonneren
Abonneer u voor het ontvangen van emails voor uw Christopeit TM450S bij:
nieuwe vragen en antwoorden
nieuwe handleidingen
U ontvangt een email met instructies om u voor één of beide opties in te schrijven.
Ontvang uw handleiding per email
Vul uw emailadres in en ontvang de handleiding van Christopeit TM450S in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.
De handleiding is 5.59 mb groot.
U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.
Stel vragen via chat aan uw handleiding
Stel uw vraag over deze PDF
Uw handleiding is per email verstuurd. Controleer uw email
Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.
Er is een email naar u verstuurd om uw inschrijving definitief te maken.
Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken
U heeft geen emailadres opgegeven
Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.
Uw vraag is op deze pagina toegevoegd
Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.