GB
- Open the gas inlet (bottle cock and/or pressure
reducing valve handle) (fig. 4).
- If bubbles appear, this means that there are gas leaks.
- To remove the leak, tighten hose nuts and/or hose
clamps if any. If a part is defective, have it replaced.
The appliance should not be returned to service until
the leak is removed.
- Close gas bottle cock.
Important:
In case of gas leak or odour, immediately close
bottle cock and/or pressure reducing valve handle.
Enhance room ventilation by opening the windows.
Ask a specialised technician to check the appliance
and proper bottle connection.
A leak test should be carried out at least once a year
and whenever the gas bottle is changed.
E - UTILISATION
OPERATING PRECAUTIONS
DO NOT install the appliance next to a wall,
curtains or a sofa or armchair.
DO NOT cover the appliance with clothes or other
objects.
DO NOT move the appliance when in operation.
The appliance must ALWAYS be directed to the
centre of the room.
The appliance must be put in a dry place.
This appliance protecting grid is designed to
prevent fire hazards or burns and no part shall be
permanently removed.
THE GRID DOES NOT TOTALLY PROTECT YOUNG
CHILDREN OR THE DISABLED.
USEFUL INFORMATION
Just after igniting the heater, small flames may
appear on the panel until reaching a certain
temperature.
As a precautionary measure, the atmosphere
analyzer will make the heater switch off
automatically if the CO
2
concentration becomes
too elevated. You will have to ventilate the room
before igniting it again.
If your gas bottle comes from a cold place it may
need some time to reach a higher temperature
and thus to work normally. The regulator is a
fundamental part for the good functioning of the
heater ; you must check that it is in good state.
The gas bottles may have at the beginning air or
impurities that make difficult the first ignition of
the heater.
Connect the other end to pressure reducing valve outlet
union.
- Check tightness in compliance with indications of
paragraph D-2.
Other countries:
The appliance is fitted with a ringed end-piece. Il must
be used with a hose the quality of which shall comply
with the use of butane or propane gas and with the
national regulations in force (BS, UNI, UNE, etc....).
The hose shall be 0.50 m long. It should be replaced
if it is damaged or develops surface cracks or when
so required by national legislation. Do not pull or twist
the hose. Keep it away from parts that are likely to get
heated.
Check tightness in compliance with indications of
paragraph D-2.
D - CONNECTING THE GAS BOTTLE
If an empty bottle is in place, read paragraph
F-”Removing or replacing gas bottle”.
To install or remove a gas bottle, always operate in a
well-ventilated place and never in presence of a flame,
spark or heat source (cigarette, electric appliance,
etc.).
The heater is equipped with a panel to protect the
gas cylinder, which should be mounted on three sides
behind the heater after connecting the cylinder (fig.4
letter B).
To attach the panel to the heater, place the panel tabs
in the body openings, as shown in fig.4 letter A, and
insert the panel in the opposite direction to the one
indicated by the arrow on the panel, in such a way as
to lock the panel tabs into the heater body (repeat this
step on the other side of the heater).
To remove the panel from the heater, slide the side of
the panel in the direction indicated by the arrow and
detach the panel from the body (fig.4 letter B). Repeat
this step for the three sides of the panel.
D - 1 - Installing gas bottle:
- Position the gas bottle on the floor behind the appliance.
- Check whether bottle cock and/or pressure reducing
valve handle is in “closed” position.
- Screw in or engage pressure reducing valve to gas
bottle or gas bottle cock (fig. 3 item B).
- Position the gas cylinder in the compartment behind
the heater, avoiding all contact between the hose and
the metal panels of the heater and checking to see that
the hose is not folded or crushed.
- Check that the hose moves freely, without twisting or
pulling.
- Replace the plastic protective panel for the cylinder by
sliding it into the slots behind the heater body which are
designed to hold it (fig.4 A).
D - 2 - Tightness:
In case of leak, appliance gas supply must be
shut down using gas bottle cock and/or pressure
reducing valve handle.
Do not carry out leak tests with a flame, use a gas
leak detecting liquid.
- Apply gas leak detecting liquid to bottle/pressure
reducing valve/hose/appliance unions.
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Campingaz Comfort Heat IR - IR 5000 Comfort bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Campingaz Comfort Heat IR - IR 5000 Comfort in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Pools als bijlage per email.

De handleiding is 2,3 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info