13
Prior to installation
Exhaust air flows upwards:
K
Cut a hole in the top of the wall cupbo-
ard, including a groove for the mains
cable.
– Template
O
I lis enclosed –.
The complete
installation set can
be obtained from
specialist outlets.
The corresponding
accessory numbers
can be found at the
end of these
operating
instructions.
Exhaust flows straight out at the
back:
– inside the wall cupboard –.
K
Cut a hole in the rear panel of the wall
cupboard, including a groove for the
mains cable.
Circulating-air mode
K With activated carbon filter if exhaust-air
mode is not possible.
Preparation:
K
Cut a hole in the top of the wall cupbo-
ard, including a groove for the mains
cable.
– Template
O
I is enclosed –.
Preparing the wall cupboard
2. Mark two points – right and left – on the
inside of the cupboard where the hood
is to be mounted, and start the hole with
a gimlet.
Details for drilling:
l 2 mm – max. 10 mm deep.
Use enclosed template
O
II for marking
points where hood is to be mounted.
Caution:
K
The mounting points shown on the
template have been configured in such
a way as to allow a 20 mm thick handle
to be attached flush with the front edges
of the cupboard.
K
If no handle is going to be attached, the
mounting points must be brought
forward by 20 mm.
If the cupboard depth is greater than
280 mm, the hood can be mounted further
back,
. . . if the light strip under the cupboard
. . . units is mounted further back,
. . . if the handle is more than 20 mm thick.
To do this, move the mounting points
further towards the back by the
corresponding distance.
3. Align the 4 enclosed mounting brackets
and screw them on tight.
Preparing the wall cupboard
Ensure that there is a minimum gap
between hob and extractor hood of 650
mm (for gas hobs) or 430 mm (for electric
hobs).
This extractor hood has been designed for
installation inside a wall cupboard with the
following dimensions:
Width: 600 mm
Depth: 280 bis 350 mm
Height:at least 280 mm.
Preparation:
1. Remove bottom panel of cupboard – if
fitted.
The stability of the cupboard must be
maintained.
Installation inside the wall
cupboard
1. Align the cupboard doors if the hinges
will no longer be accessible after the
extractor hood has been fitted.
2. Place the extractor hood onto the
mounting brackets and push it into the
cupboard.
Important: The extractor hood must be
firmly seated on the 4 mounting
brackets.
3. Loosely screw in the 4 enclosed screws.
Align the extractor hood and then
tighten screws.
Check that the extractor hood is firmly
fitted into the cupboard.
4. Install a shelf immediately above the
extractor hood. Cut holes for the pipe
connection and the mains cable.