8.3 Automatic measurement of the open-circuit voltage, short-circuit current and insulat-
ing resistance of the PV generator
c
The PV module/ PV string must not exceed the maximum opencircuit voltage
of 1000 V DC, the maximum short-circuit current of 15 A and the maximum DC
power (P = U x I) of 10 kW.
According to DIN EN 62446, the measurements have to be made for each PV string.
Measurements made at PV strings which are connected in parallel might in-
volve an overload of the BENNING PV 1-1.
m
During the insulating resistance measurement, the PV generator is shorted.
Measurement is made between the red 4 mm test socket and the shorted PV
test sockets.
m
In case DC polarity is wrong or DC voltage is within the range of < 5 V or
> 1000 V, it is not possible to make an automatic PV measurement.
- Connect the BENNING PV 1-1 to the PV module or the PV string by means of the enclosed
PV safety measuring leads.
- For insulating resistance measurement, connect the red safety measuring lead of the 4 mm
test socket L to a metal part (frame or mounting system) of the PV generator.
- If the PV generator is properly earthed by means of an earthing conductor, the red safety
measuring lead of the 4 mm test socket L can be connected alternatively to a safe earth
connection (equipotential busbar).
- Measurement of the PV open-circuit voltage is made automatically, if a DC voltage is applied
to the PV safety measuring leads (test sockets
9
and
J
).
- In case of reversed polarity of the DC voltage, the polarity indication is flashing and the
symbol E is displayed. Automatic measurement will be blocked until the polarity of the DC
voltage is correct.
- As soon as a voltage of > 30 V is applied to the PV safety measuring leads, the
c
warning
symbol F (Attention, dangerous voltage) is flashing.
- In order to set the testing voltage for measuring the insulating resistance , press the
V
ISO
-key
5
and select the desired testing voltage (250 V, 500 V or 1000 V DC).
- Press the
Auto
-key
3
to start the automatic PV measurement. The following measurements
will be made:
- measurement of the PV open-circuit voltage
- measurement of the PV short-circuit current
- measurement of the insulating resistance
- The measured values will be shown on the display
1
for approx. 20 seconds or until a key
is pressed.
- If the measured insulating resistance is higher than the preset limiting values, the sym-
bol will be displayed next to the insulating resistance value. If the insulating resistance value
is lower than the limiting values, the symbol will be displayed.
See gure 6: Automatic solar panel measurement, ISO measurement via earthing conductor
Preset limiting values:
V
ISO
Limiting value of insulating resistance
250 V 0.5 MΩ
500 V 1.0 MΩ
1000 V 1.0 MΩ
8.4 AC/ DC voltage measurement
- Disconnect the PV safety measuring leads from the PV test sockets
9
and
J
.
- Connect the red and black safety measuring lead to the corresponding 4 mm test sockets K
and L.
- Connect the measuring probes to the voltage source to be measured.
- The BENNING PV 1-1 automatically measures the voltage at the measuring probes.
- The polarity of the DC voltage is displayed by “+ / –“ A. In case of AC voltage, “+ / –“ A will
be displayed alternately.
See gure 7: Voltage measurement via 4 mm test sockets
8.5 Current measurement by means of optional AC/ DC current clamp adapter
BENNING CC 3 (part no. 044038)
By means of the optional AC/ DC current clamp adapter BENNING CC 3, the BENNING PV 1-1
can be used to measure the operating current of a PV system. The determined current values
can be stored in the internal memory of the BENNING PV 1-1 and can be recalled.
- Disconnect all measuring leads from the BENNING PV 1-1.
- Connect the BENNING CC 3 current clamp adapter to the 4 mm test sockets K and L of
24

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Benning PV 1.1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Benning PV 1.1 in de taal/talen: Duits, Engels als bijlage per email.

De handleiding is 10,6 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Benning PV 1.1

Benning PV 1.1 Snelstart handleiding - Nederlands, Français, Italiano, Espanõl - 14 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info