660523
11
Verklein
Vergroot
Pagina terug
1/19
Pagina verder
11 XENYX X2442USB/X2222USB/X1832USB/X1622USB User Manual
Possible applications for the Voice Canceller are obvious: you can very simply
stage background music for Karaoke events. Of course, you can also do this at
home or at your rehearsal room before you hit the stage. Singers with their own
band can practice singing dicult parts using a complete playback from a tape
player or a CD, thus minimizing rehearsal time.
2.3.8 CD/Tape input, CD/tape output
X2442USB
Fig. 2.15: 2-track connectors and lamp socket
CD/TAPE INPUT
The CD/TAPE INPUT jacks (RCA) are designed to accept a 2-track recorder
(e.g.DAT recorder), or they can be used as stereo line input. The output signal of
a second XENYX or the BEHRINGER ULTRALINK PRO MX882 can also be connected
here. If you connect the output of a hi- amplier (with a source selection switch)
to the CD/TAPE INPUT, you can easily listen to additional sources (e.g. cassette
recorder, MDplayer, sound card, etc.).
Using the voice canceller function (X1832USB only), you can process all signals
being brought into your mixing console via these connectors.
CD/TAPE OUTPUT
These connectors are wired in parallel to the MAIN OUT and carry the main mix
signal (unbalanced). Connect this to the inputs of your recording device. The nal
output level can be adjusted via the high-precision MAIN MIX fader.
If you connect a compressor or a noise gate post 2-track output,
the main mix fader will probably not be able to create a satisfactory
fade-out effect.
2.3.9 Lamp socket (X2442USB only)
Use this BNC socket to connect a gooseneck lamp (12 V DC, max. 0.5 A).
2.3.10 Level meter and monitoring
X2442USB
Fig. 2.16: Control room and phones sections of the X2442USB
CD/TAPE
The CD/TAPE switch routes the signal from the CD/TAPE INPUT jacks to the level
meter, the CONTROL ROOM OUT outputs and the PHONES jack—this is a simple
way to check recorded signals via monitor speakers or headphones.
SUB 1-2 or SUB
The SUB 1-2 switch routes subgroup 1-2 to the level meter, CONTROL ROOM OUT
and phones.
SUB 3-4
The SUB 3-4 switch performs a similar function for subgroup 3-4
(X2442USBonly).
MAIN MIX
The MAIN MIX switch sends the main mix to the CONTROL ROOM OUT and the
PHONES output as well as to the level meter.
PHONES/CTRL ROOM
Use this control to adjust the control room output level and the
headphonesvolume.
CD/TAPE TO MAIN
When the CD/TAPE TO MAIN switch is depressed, the 2-track input is routed to
the main mix and thus serves as an additional input for tape machines. Youcan
also connect MIDI instruments or other signals here that do not require any
further processing. At the same time, this switch disables the main mix to tape
output link.
POWER
The blue POWER LED indicates that the device is switched on.
+48 V
The red “+48 V” LED lights up when phantom power is switched on.
Phantompower is required to operate condenser microphones.
While phantom power is switched on, do not connect or disconnect
microphones on the mixer (or the stagebox/wallbox). Connect any
micro-phones before switching on phantom power. Additionally,
monitor/PA speakers should be muted before you activate the phantom
power supply. After switching on, wait approx. one minute before
adjusting the input gain so that the system has time to stabilize.
2. 3.11 Level Meter
The high-precision level meters always give you an accurate display of
signallevel.
LEVEL SETTING:
When recording to digital recorders, the recorders meter should not go into
overload. This is because, unlike analog recordings, it takes only slightly excessive
levels to create unpleasant digital distortion.
When recording to analog, the VU meters of the recording machine should reach
approx. +3 dB with low-frequency signals (e.g. kick drum). Due to their inertia,
VU meters tend to display too low a signal level at frequencies above 1 kHz.
Youshould only drive instruments such as a Hi-Hat as far as -10dB. Snaredrums
should be driven to approx. 0 dB.
The peak meters of your XENYX display level almost independent of
frequency. A recording level of 0 dB is recommended for all types
of signal.
MODE
The MODE switch determines whether the channels’ SOLO switch operates as PFL
(Pre Fader Listen) or as solo (Solo In Place).
11

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Behringer Xenyx X2442USB bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Behringer Xenyx X2442USB in de taal/talen: Engels als bijlage per email.

De handleiding is 5,74 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Behringer Xenyx X2442USB

Behringer Xenyx X2442USB Snelstart handleiding - Deutsch, English, Français, Português, Espanõl - 18 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info