9
EG
PORTHOLE KIT
ASSEMBLING
●
Make a hole in the window
pane.
●
Insert the porthole without the
plug.
●
Remove the terminal pipe
fitting of the warm air outlet
from the retractile flexible
pipe.
●
Bring the air conditioner near
the window and insert
the air outlet in the porthole.
If you want to utilise the air conditioner in several rooms, it is
possible to buy varies portholes for air discharge separately.
CARE AND CLEANING
WARNING! For safety’s sake, be sure to turn the air conditioner OFF and also disconnect it from the power supply before cleaning
it.
1. Cleaning of the Air Filter
The air filter must be checked at least once every two weeks operation. Operation with a dirty filter always causes a lower effi-
ciency of the air conditioner and severe product damage.
The filter can be removed from the upper part of the unit, removing the upper panel and pulling upwards. Use a vacuum cleaner
to remove light dust. If there is sticky dust on the filter, wash it with lukewarm soapy water, then rinse in clean, cold water and dry
it before reinstallation.
135 mm
In the win-
dow pane
In the wooden
kickboard of a
french window
In the wall: you are
recommended to
insulate the section of
the wall using suita-
ble insulation
FILTER CLEANING
Filter