537058
6
Verklein
Vergroot
Pagina terug
1/13
Pagina verder
6
Digital coding system
This monitor is equipped with a digital coding system which eliminates
interferences. The codes are written on the box and in the battery
compartment. For use of 2 Angelcare Movement and Sound Monitor in same
household or when interferences occur with an Angelcare in another
household, ensure the 2 monitors have 2 different digital coding system.
In range feature
This monitoring system is equipped with an In Range indicator. To
activate this function press the night light button and hold it until the
halo light flashes. If units are within range, the In Range light will flash.
If out of range the In Range light will be ON with no flashing. To
deactivate the In Range function, press and hold the night light button
again until halo flashes. The In Range light will turn OFF.
NOTE: The parents unit has a range up to 120 meters (394 feet).
AC power source
Model AC301: The AC adapters should be used whenever possible to
extend the battery life. Batteries can be kept in units while using AC
power source. Use regular AAA batteries for the AC301 model.
Model AC301-R: Use AC adapter on Nursery Unit whenever possible to
extend the batter
y life. For Parents Unit, use AC adapter ONLY to charge
NiMh batteries. Only charge batteries when low battery indicator is on. Do
not overcharge. Only use rechargeable batteries for the AC301-R model.
Warning: Damages caused by misuse of the monitor are the customer
responsibility.
Replacing the rechargeable batteries (Model AC301-R only)
When the NiMh batteries in the Parents Unit will not charge or
only hold their charge for a short period of time, batteries need to
be replaced. Unscrew the battery compartment door on the Parents
Unit (if necessary). Remove old batteries. Insert new rechargeable
batteries. Screw in the battery compartment door. Plug the Parents Unit
into an electrical outlet. Use only rechargeable batteries in the Parents
Unit. Allow new batteries to charge continuously for 15 hours.
Problem Possible Cause Solution
False alarms.
Baby was removed from crib and Nursery Unit was not switched OFF.
• Sensor Pad cord not connected properly to Nursery Unit.
Sensor Pad is not in full contact with crib mattress, or crib
mattress is not resting on a completely flat or rigid surface.
• Baby has moved away from Sensor Pad, to the edge of the crib.
• Turn Nursery Unit to the OFF position.
• Verify the connection between the Sensor Pad and Nursery Unit.
Unplug and reconnect the cord.
Make sure there is no bedding between mattress and Sensor
Pad. Sensor Pad
must
rest on a completely flat and rigid
surface. Place a piece of 6 mm (1/4”) plywood to cover the
full size of the crib base.
• Make sure Sensor Pad is positioned as described in the 5 Easy
Steps section. Sensitivity may need to be adjusted, consult the
Movement Sensitivity Adjustment section.
Alarm indicator light is flashing red
(monitor is barely detecting
movement).
Sensor Pad is not in full contact with crib mattress, or crib
mattress is not resting on a completely flat or rigid surface.
Baby is in a very deep sleep or has moved away from Sensor Pad,
to the edge of the crib.
• Make sure there is no bedding between mattress and Sensor Pad.
Sensor Pad
must
rest on a completely flat and rigid surface. Place
a piece of 6 mm (1/4”) plywood to cover the full size of the crib base.
• Make sure Sensor Pad is positioned as described in the 5 Easy
Steps section. Consult Movement Sensitivity Adjustment section.
No sound is being transmitted.
Units are too far apart (in range indicator is off on the Parent Unit).
Batteries are low or improperly installed.
AC adapters are not connected properly or electrical outlet is
out of order.
• One of the units is not ON.
• Bring Parents Unit closer to Nursery Unit.
• Check/replace batteries or recharge Parents Unit
(Model AC301-R only).
• Check connections or change to another electrical outlet.
• Ensure both units are ON.
• Make sure both units are on the same channel, either A, B or C.
Power ON indicator (green light)
does not light up.
Batteries are low or improperly installed.
• AC adapters are not connected properly or electrical outlet is
out of order.
• One of the units is not ON.
• Check/replace batteries or recharge Parents Unit
(Model AC301-R only).
• Check connections or change to another electrical outlet.
• Make sure both units are ON and on the same channel, either
A, B or C.
Static, distortion, interference (interference
from other monitors, wireless phones,
walkie-talkies, etc…).
• Parents Unit is out of range.
• Units are set to different channels.
• Parents Unit located near motorized devices, fluorescent lights,
television, etc…
There is an Angelcare Monitor in another household nearby.
• Bring units closer together.
• Make sure both units are ON and on the same channel, either
both on channel A, B or C.
Rotate Parents Unit or move it away from source of
interference.
The digital codes are the same on the 2 monitors. Verify the
digital coding on the box or in the battery compartment.
Feedback (loud noises emitted from
Parents Unit).
• Units are too close to each other. • Move units farther apart (at least 3 meters/10 feet apart).
• Decrease volume on Parents Unit.
Weak reception but the in range
indicator is not lit.
The in range option is off. Use the night light switch to activate the range out feature.
Press it and hold for 2 seconds.
Very weak reception.
Units are too far apart (in-range) indicator will flash rapidly and
beep on the parent unit.
• One or both units are placed near a large metal mass.
• One or both units are not in the upright position.
• Batteries are low.
• Bring units closer together.
• Change the position of one or both units.
• Place units on flat surface away from baby’s reach.
• Replace the batteries or recharge Parents Unit
(Model AC301-R only).
Alarm will not sound.
• Nursery Unit is detecting movement when crib is being touched.
• Nursery Unit is detecting movement from outside the crib such
as motorized devices, strong drafts, etc…
Sensitivity is set too high.
• Avoid contact with the crib when monitor is ON.
Place crib near a solid supporting wall to avoid Sensor Pad
from detecting movement from outside crib.
• You may need to decrease the sensitivity, consult the
Movement Sensitivity Adjustment section.
TROUBLESHOOTING
ManAC301 angl-fra 14 july06.qxd 7/14/06 9:29 AM Page 6
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Angelcare AC301 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Angelcare AC301 in de taal/talen: Engels, Frans als bijlage per email.

De handleiding is 1,13 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Angelcare AC301

Angelcare AC301 Gebruiksaanwijzing - Nederlands, Deutsch, Português, Espanõl, Polski, Dansk, Svenska, Norsk, Suomi - 72 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info