Technical data AD 700
Supply voltage 9-15V DC
- Voltage monitoring Alarm at <7 V+/- 0,5V
Current consumption at 12V
- Quiescent 16 mA
- Alarm state 14 mA
Alarm relay Normally Closed 500 mA/max 100V DC/R<40 ohm
Tamper contact rating 50 mA/max 50V DC
Coverage
- Max range 9 m radius/165°
- Range setting Zone 3 = 1-2 m
Zone 2 = 2-4 m
Zone 1 = 4-9 m
- Size of glass to be protected min 30x30 cm, max 6x6 m
- Max thickness of glass 6,5 mm
- Approved glass Standard window glass (float glass)
Volume of protected room min 20 m
3
, max 250 m
3
Operating temperature -10° to +55° C
Humidity (DIN 40040) <90% r.h. (class F)
Housing protection category IP31
Approvals
VdS Klasse B G104512
Techom Pending
INCERT Pending
National approval conditions relating to the use
of the detector must be followed!
Alarmtech reserves the right to change specifications without prior notice.