A b b ./ g ./s c h é m a/a. / ill. 2
A b b ./ g ./s c h é m a/a. / ill. 1
1
2
3
5 6 4
7
9
8
A b b ./ g ./s c h é m a/a. / ill. 5
5
4
7
A b b ./ g ./s c h é m a/a. / ill. 3
A b b ./ g ./s c h é m a/a. / ill. 7
A b b ./ g ./s c h é m a/a. / ill. 4
D Sabotageschalter
G Sabota ge swtich
n Sabotageschakelaar
D IR-Diode
G Infr ared-Diode
n Infr arooddiode
D Kontr oll-LED
G Contr ol-LED
n Contr ole-LED
+
-
A b b ./ g ./s c h é m a/a. / ill. 6
WEEE-Reg-Nr .
DE 79663311
FG3 50E Sec v est
Tec hnische Änderu ngen vo rbehalte n. Für Irrtümer und Druckf ehler k eine Haung. ABUS © 9/20 15 | ABUS Security-C enter GmbH & C o. KG | Link er Kr euthwe g 5 | 86444 Ang (German y)
Subject to tec hnical alter ations. No liability fo r mistak es and print ing err ors. ABUS © 9 /201 5
Tec hnische wijzi gingen v oorbehouden. Geen aanspr akelijkheid v oor ve rgissi ngen en druk fouten. ABUS © 9/2 015
Monta ge- und Bedienun gsanleitung f ür ABUS Funk -Fenste rgri F G350E
Diese Anleitung ist wie folgt u nter gliedert
I. Allgemeines und Batt eriehinw eise
II. Einsatzmöglichk eiten
III. Packun gsinhalt
IV. Montagewerkzeug
V. Montage und Einlernvor gang
VI. Bedienung und Batte riewechse l
VII. Technische Daten
I. Allgemeines und Ba tteriehin weise
Dieses Produkt erfüllt die Anfor derung en der gelte nden europäis chen und nation alen Richtlinien. Die K onformit ät
wurde nachgewies en, die entsprec henden Erkläru ngen und Unterl agen sind beim Her steller (www .abus.com)
hinterlegt.
Um diesen Zustand zu erhalten u nd einen gef ahrlosen Betrie b sicherzustellen, muss der Anwende r diese Installa-
tionsanleitung be achten.
Das gesamte Pr odukt darf nic ht ge ändert bzw . umgebaut wer den. Das gilt be sonders für die interne Antenne und
den Drehkondens ator . Ebenfalls sollte ein F inger k ontakt mit der Plati ne vermiede n werde n. Der zugela ssene Einsat -
temperatur bereich be tr ägt – 10°C bis +55°C bei einer ma ximalen Luf euchti gkeit von 90 %.
Weder der Verf asser noch ABUS-SC k ann eine Haung f ür einen V erlust oder Schaden über nehmen, der mitt elbar oder
unmittelb ar aufgr und dieser Anleit ung ver ursac ht wur de oder vo n dem behauptet wird, da ss er dadur ch entst anden ist.
Der Inhalt dieser Anleitung k ann ohne vo rherige B ekann tgabe ge ändert werden.
Sicherheitshinw eise:
Das gesamte Pr odukt darf nic ht ge ändert bzw . umgebaut wer den. Ebenf alls sollte ein Fin gerko ntakt mit de r Platine
vermieden werden.
Vorsicht im Umg ang mit dem Ma gneten:
• Gefahr des Einklemme ns der Fing er!
• Produkt von K indern fe rnhalte n wegen versc hluckbar er Kleinteile .
• Insbesondere beim V erschluck en des Magneten ist un verzüglich ärz tliche Hilfe in Anspr uch zu nehmen.
• Kredit- oder EC -Karten mit Magne tstreife n könnte n geschädi gt wer den.
• Für Personen mit He rzschritt macher , Debrillator ode r sonstig en implantierten Ge rät en gilt: Der Ma gnet k ann
solche Geräte ne gativ beei nussen, daher ins besondere bei der Monta ge ausreic henden Abstand (c a. 20 cm)
zwischen Magnet und i mplantiertem Ger ät einhalten.
Batter iehinweise:
Das Gerät wird mit Gleic hspannung über ei n Stück 3 ,6V SAFT L S 142 50 Lithium-B atterie versor gt , die i m Lieferumf ang
enthalten ist. Beim Einle gen der B atterie ist auf richti ge Polarit ät zu acht en.
Um eine lange Lebensdauer zu gewährleisten und Br ände und Verletzunge n zu ver meiden, sind folgende Hi nweise
zu beachten:
• Gemäß Batterie ver ordnung ist die Entsor gung v on Batt erien über den H ausmüll ver boten, diese müssen an
gekennzeichne ten Sammelst ellen abgege ben werde n.
• Batterien dürf en weder dir ekter Sonneneinstr ahlung noch anderen W ärmequellen ausgese tzt oder an Orten mit
sehr hohen Te mper aturen auew ahrt wer den.
• Batterien gehö ren nicht in Kinderh ände und sind nicht wiede r auadbar .
• Batterien dürf en nicht
• zerlegt, angest ochen oder besc hädigt werden
• verbrannt werden
• mit Wasser in Berührung kommen
• kurzgeschlossen werden
II. Einsatzmö glichk eit
Der Fu nk -Fenstergri FG350E bietet ne ben der normalen B edienung eines Fe nsters mit Ei nhand-Dreh-Kipp-B eschlag
die Funktionalität eine s klassischen Ö nungsmelder s sowie eine Detekt ion der Grist ellung und k ann diese als
Zustandsmeldung (F enster geö net oder Fenster verrie gelt) an das sep arat e ABUS Funk -Anzeigemodul F A 01 und/oder
eine Önung an alle ABUS Funk alarmanlagen der Secvest Ran ge, an das IP Al armmodul und über ein F unkerweit e
rungsmodul auch an die ver dr ahtete ABUS Alarmanl age T erxo n MX und LX melden.
Die Funkreich weite im Geb äudeinneren bet rä gt ca. 30 m und ist abhängig von der B ausubstan z des Gebäudes sowie
den s onsti gen Umweltbedingungen.
III. Pac kungsinh alt (siehe Abb. 1)
1. Drehgri 6. Magnethalter
2. Elektroni keinheit 7 . Befestigungss chr aube 2, 9 x 16 mm
3. Batterie 8. Vierkan tsti, Arretiersc heibe,
4. Mag nethalter befesti gung Bef estigu ngsschr auben M5 x 35 mm und M5 x 45 mm
5. Unterla ge 7 mm 9. Ausgleichsri nge (2 Stüc k)
IV. Monta gewerkzeug
• Kreuzschlitz- u nd Flachschr aubendreher
V. Monta ge und Einlern vorg ang
V. 1. Montage:
Vor der Montage des FG3 50E ist der v orhandene Gri in Önungsst ellung zu brin gen und zu demontieren.
• Elektroni keinheit mit achem Sc hraube ndreher aus dem Gri lösen (siehe Abb. 3).
• Länge des V ierk antsties mit Arret ierscheibe ( 8) anhand de s alten Grie s einstellen (Abb. 2 ).
• Wenn die Durc hmesser der Befesti gungslöcher im Fenster gleich oder gr ößer 12 mm sind, Ausgleichsr inge ( 9)
auf die Nock en des Gries st eck en.
• FG350E in waager echt e Stellun g bringen und mit 2 Schr auben M5 x 35 mm oder M5 x 4 5 mm montieren.
• Monta ge des Magnet halters: M agnethalt erbefest igung ( 4) und Unterla ge 7 mm (5) k önnen mit den aufgesetzten
Klebefolien ohne Schr aube befesti gt wer den, wir empf ehlen jedoch die Sc hrau bmontag e (vor bohr en bei Kun st-
sto nicht nöti g). Die Unterlag e 7 mm kann bei F alzhöhen ab 20 mm die Funktion des Magnetkontaktes ver-
bessern (siehe Abb. 5).
• Position des Magne thalter s: Mitte Mag nethalter in Höhe der Unt erkan te des Grisoc kels (siehe Abb. 5)
• Seitlicher Abstand zum F ensterügel: ma x. 3 mm (siehe Abb. 5 ).
• Magnethalter (6) aufdrück en.
V.2. E inlernvor gan g:
• An F A 01 oder Secvest F unkalar manlage /IP-Alar mmodul /Funke rweiterunge n Te rxon muss die Z one fest gelegt
werde n, auf der FG3 50E eingeler nt wer den soll (siehe hierzu die Mon tage anleitung des entspreche nden Ger ätes).
• Batte rie polungsr ichtig i n Elektronik einheit einlegen (Abb. 5).
• Sabota geschalt er vo n Hand kurz bet ätigen und wieder loslassen (Ab b. 5).
• Durch d as Önen des K ontakte s wird der FG350E mit ei nem Funksig nal an F A 01 oder Secvest IP-Alar mmodul /
Funkerweiterungen T erxon eingelernt (Abb. 5).
• An F A 01 oder Secvest F unkalar manlage /IP-Alar mmodul /Funke rweiterunge n Te rxon wi rd das erf olgreiche
Einlernen ak ustisch quitt iert.
• Nach dem erfolgr eichen Einle rnen des FG3 50E an Alarmanla ge / F A01 oder Se cvest Funk alarmanlage / IP-Alarm
modul /Funke rweiterung en T erxon die Elekt ronik einheit in den Gr i lageric htig eins chieben (Abb. 6 ).
• Zum Einler nen von weite ren FG35 0E die entspreche nden Zone n auswählen, Vo rge hensweise entspr echend
Punkt V .2.
• Es kann nur ein FG350E pr o Zo ne eingelern t wer den, (Ausnahme Secv est IP: Hier k önnen bis zu 3 bzw . 4 Melder
pro Zone eing elernt werden) jedoc h kann ein F G350E sowohl an F A 01 als auch der Secv est Funk alarmanlage
sowie dem IP-Alarmmodul /Funk erweiterungen T erxo n eingeler nt wer den.
V.3 . Infr arotdiode (Abb . 5) zum Einler nen in ve rdr ahtet e ABUS-Alarmanla ge Te rxon über separ ates Funk erweiterungs
modul:
• Siehe Produktprogr amm ABUS Security-Cent er .
• Informat ionen zur Inst allation sind in de n Unterlagen zur Alarm anlage T erxo n zu nden.
VI. Bed ienung und Ba tteriewechs el
VI. 1. Bedienung:
Der Funk-Fenste r gri FG3 50E bietet neben der norm alen Bedienung eines F ensters mit E inhand Dreh-K ipp
Beschla g die Funktionalit ät eines kl assischen Önun gsmelders sowie eine D etektion der Gristellun g und k ann
diese als Z ustandsmeldun g (Fenster g eönet oder Fenster verrie gelt) an das sep ar ate ABUS Fu nk-Anz eigemodul
FA 01 und/oder eine Ö nung an die ABUS – Secvest F unkal armanlage /IP-Alar mmodul und über ein Fu nk-
erweiterungsmodul auch an die ver dr ahtete ABUS Alarmanlage T erxon melden.
Dabei gilt:
Fenster p ar allel zum Fenste rrahme n und Gri in V ersc hlussstellung (Fenst er gesc hlossen) –> Zo ne geschlossen
(oder LED grün bei F A 01). Alle davon ab weichenden Sz enarien –> Z one oen (oder LED rot am F A 01).
VI.2. Batter iewechsel:
• Der Bat teriest atus des FG3 50E wird mit dem Funksig nal übertr agen.
• Ein notwendige r Batt eriewec hsel wird ü ber eine Meldun g (Low B att) an F A 01 oder Secvest F unkalar manlage /IP
Alarmmodul /Funk erweiterungen T erxo n angezei gt.
• Wenn der FG350E in die ABUS Secvest Funk alarmanlage /IP Alarmmodul / Funk erweiter ungen T erx on eingeler nt
ist, muss die Alarmanlage vor einem B atter iewechsel in de n Errichte rmodus gesetzt werden, d a ansonsten dur ch
den betäti gten Sabot agek ontakt ei n Alarm ausge löst wer den wür de (siehe Bedienungs anleitung der je weiligen
Alarmanla ge).
• Zum B atter iewechsel mit kleinem Schlitz schr aubendr eher die V erriege lung der Elekt ronik einheit lösen (Abb . 7).
• Elektroni keinheit he rauszie hen
• Alte B atterie en tnehmen und neue Bat terie polungs richti g einlegen (Ab b. 4, Zonenbele gung bleibt erhalten).
• Anschließend Ele ktronik einheit lagerichti g wieder einsc hieben, wodur ch der S abotages chalter erneut bet ätigt
wird (Z onenbelegu ng bleibt er halten, Abb . 6).
• Errichte rmodus der jeweili gen Alarmanl age k ann jetzt wieder verla ssen wer den.
VII. T echnische Dat en
Spannungsversor gung: 1 x 3 ,6V Lithiu m-Thionylchlor id
Batteri etyp: SAFT LS 14250
(bitte ausschließ lich diese Bat teriety pe verwende n,
um einwandf reie Ger ätefunktion zu gewährleiste n)
Frequenz: 868 ,663 5 MHz/AM
Batterielaufzeit: ca. 3 Jahre
Umweltklasse: II
Temper aturber eich: – 10°C bis + 55°C
Installation and Oper atin g Instructions for the ABUS wir eless window h andle FG350E
These instructions ar e comprised of the followin g sections
I. Gener al inform ation and notes conc erning the b attery
II. Applications
III. P ackage con tents
IV . Assembly tool
V. Installatio n and lear ning proc ess
VI. Oper ation and replaci ng the batt ery
VII. Technical dat a
I. Gener al information and no tes conc erning the ba ttery
This product fulls the requir ements of the v alid European and nat ional direct ives. Pr oof of conf ormity and
the relevan t and document ation are on le with the manu factu rer (www .abus.com).
In order to obt ain this condition and ensur e saf e oper ation, the user must observe the se instructions.
No part of the product ma y be alter ed or modied. This applies in p articular fo r the inter nal antenna and the
variable capacit or . Make certain also not to touch the cir cuit board with the nger s. The permitt ed oper ating
temperatur e r ange is fr om – 10°C to +5 5°C, with a maxi mum relati ve humidity of 90%.
Neither the author nor ABUS-SC can assume liability for loss or damage r esultin g directly or indirectly fr om
these instructions or f or whic h this is claimed. The cont ents of these inst ructions are su bject to chan ge
without prior notice.
Safety in form ations:
The product should not be chang ed or modied. Also ng er cont act with the boar d should be avoided.
Be careful w hen using mag nets:
• Risk of t rappi ng nger s!
• Keep product a way f rom c hildren due to small p arts.
• In particular , seek immediate medic al attent ion if mag net is swallowed.
• Credit o r debit car ds with ma gnetic strips m ay be dam aged.
• For persons with pacemak ers, debrillators or other implanted de vices – the mag net may advers ely aect
such device s, so ensure sucient distance (appr ox. 2 0cm) between the mag net and implant ed device
during inst allation.
Notes conc erning the b attery:
The device is supplied with DC v oltage f rom a sin gle 3,6V SAF T LS 14 250 lithium b attery , included in delivery
he correct polarity must be ensured when insertin g the batte ry .
In order to ensure a lon g service life and t o prev ent r es and injuries, the f ollowing note s must be observed:
• In accordance with the batte ry directi ve, the dispos al of batt eries in household r efuse is f orbidden.
Batte ries must be disposed of at collection points ident ied for this pu rpose.
• Batte ries may not be exposed to di rect sunli ght or other he at sour ces or stor ed in places with very hi gh
temperatures.
• B atterie s must be kept a way from c hildren and c annot be rec har ged.
• B atterie s may not
• be t aken ap art, pierced or otherwis e damaged
• be bur ned
• come into contact with w ater
• be short -circuit ed
II. Applications
Besides normal window ope rat ion via sin gle-handed tilt -rotat e tting, t he FG350E wir eles lock able window
handle also oers the function ality of a classic openi ng detector and detects the handle position.
The device can sign al this as a status r eport (window ope n or window loc ked) to the s epar ate ABUS F A 01
wireless display module and/o r the ABUS – Secvest alar m panel, to the IP alarm module (CAS A10010) and
also via a wireless modulee xtension (AZ4 120 or AZ42 20) t o the wired ABUS T erxon MX and LX alarm s ystems.
The wireless r ange withi n buildings is appro ximately 30m, depending on the buildi ng materi al and other
environment al conditions.
III. Packa ge cont ents (Fi g. 1)
1. Rot ary handle 6. 7 mm washer
2. Electronics unit 7 . 2.9 x 16 mm attac hment scr ew
3. Batt ery 8. Split spindle, locking dis c and M5 x 3 5 mm
4. Mag net holder att achment and M5 x 4 5 mmattachment scr ews
5. 7 mm washe r 9. Equalising ri ngs (2 pieces)
IV . Assembly tool
• Phillips-he ad and at-he ad screwdriv e
V . Installation and le arning proc ess
V. 1. Installation:
Before inst alling the FG3 50E, turn the e xisting h andle to the open position and det ach the handle.
• Remo ve the electr onics unit f rom the handle usi ng the at-he ad screwdriv er (Fi g. 3).
• Adjust t he length of the split spi ndle with lockin g disc (8 ) using the old handle (F ig. 2).
• If t he diameter of the attac hment holes in the window is 12 mm or more, plac e the equalising rin gs (9)
on the handle tappets.
• Bri ng the FG35 0E to the horizont al position and assemble with two M5 x 3 5 mm or M5 x 45 mm
attachme nt scr ews.
• Assembli ng the magne t holder: the magne t holder att achment ( 4) and 7 mm washe r (5) c an be attached
without the need f or scr ews by apply ing adhesiv e lm, but we r ecommend scr ew assembly
(no pre-dr illing necess ary with plast ic). The 7 mm was her can impr ove ma gnetic cont act with r abbet
heigh ts gre ater t han 20 mm (Fi g. 5).
• Posit ioning the mag net holder: the cen tre of t he magnet holde r should be leve l with the lower edge of
the handle base (Fig. 5 )
• Lat er al distance f rom the c asement: ma x. 3 mm (Fig. 5).
• Ax magnet holde r (6 ).
V .2. L earnin g process:
• With the F A 01 or Secvest al arm panel / IP alarm module / Terx on wir eless ext ensions, it is necess ary
to dene the zone f or the FG3 50E le arning pr ocess (see also the inst allation instr uctions for the
relev ant de vice).
• Insert the bat tery with the co rrect polar ity in the elect ronics unit (F ig. 5).
• Briey actuate the s abotag e switch manually and then r ele ase it ag ain (Fig. 5 ).
• The opening of the co ntact caus es the FG350E t o send a wir eless le arning si gnal to the F A 01 or
Secvest alarm panel / IP alar m module / Terx on wireless exte nsions (Fig. 5). With the T erxon wireless
extensions, the component lear ning proc ess tak es place vi a the LED (observe t he installatio n
instructions for the r elev ant wir eless e xtension).
• Successful le arning is acoustically acc epted for the F A 01 or Secvest alar m panel / IP alarm module /
Terx on wir eless ext ensions.
• Following succ essful le arning of the FG350E to t he FA 01 or Secv est alarm p anel / IP alarm module /
Terxon wireless e xtensions, push the ele ctronics unit into the corr ect position withi n the handle (Fig. 6 ).
• Repe at the le arning pr ocess f or additional F G350E devic es in accor dance with Se ction V .2., dening the
respective zones.
• Only one FG3 50E per zone c an exe cute the le arning pr ocess (with the e xc eption of the Se cvest IP:
here up to 3 or 4 detector s per zone c an exe cute the le arning pr ocess), ho ev er FG3 50E can ex ecute the
learning pr ocess either to an F A 01 or to a Secvest alar m panel / IP alarm module / T erxon wirele ss
extensions.
V.3 . Infr ared diode (Fi g. 5) for le arning vi a a separ ate wir eless ext ension module in the wir ed ABUS Terx on
alarm system:
• See ABUS Secu rity-Cent er product line.
• Inform ation about inst allation can be f ound in the document ation f or the T erx on alarm system.
VI. Operation and replac ement of the ba ttery
VI. 1. Operat ion:
Besides normal window ope rat ion via sin gle-handed tilt -rotat e tting, the F G350E wir eless lock able
window handle also oers the f unctionality of a cl assic opening dete ctor and detects the h andle
position. The device can si gnal this as a st atus report (wi ndow open or window lock ed) to the separ ate
ABUS FA 01 wireless displa y module and or an ope ning to the ABUS Secvest alar m panel / IP alarm
module and also via a wireless module e xtension to the wired ABUS T erxon alar m system.
The following points are ne cessary her e:
Window par allel to the window f r ame and handle in the closed positio n (window closed) –> zone
closed (or LED green fo r F A 01). All other scenarios –> zone open (or LED r ed on the F A 01).
VI.2. Replacing the battery:
• The batte ry status of the F G350E is tr ansmitted by a wir eless sig nal.
• The need to replac e the battery is indicated b y a sign al (Battery Empty) to the F A 01 or Secvest alar m panel / IP
alarm module /Terx on.
• When the FG35 0E has ex ecuted the le arning process in the ABUS Secvest alarm panel / IP alar m module / Te rxon
wireless extensio ns, before r eplacing the b attery it is necessary to set the alar m system
to the installer mode, as the actuat ion of the sabot age switc h would otherwise t rigger an alarm
(see the operatin g instructions f or the r espective de vice.
• To r eplace the bat tery , loosen the locking mec hanism for the electr onics unit with a small Phillips -he ad
screwdriver (Fig. 7).
• Remove t he electronics unit.
• Remove t he old battery and i nsert the new b attery with the correct polarity (Fi gure) (zo ne denition
remains in tact).
• Then push the electr onics unit bac k into the cor rect positio n, again actuatin g the sabot age switch
(the zone denition remai ns intact).
• Y ou can now e xit the installe r mode of the alarm s ystem again.
VII. T echnical dat a
Supply voltage: 1 x 3,6V Lithium-Thionylc hloride
Batter y type: SAFT LS 14250
(Plea se only use this ty pe of batt ery to ensure
proper f unctioning of t he equipment)
Frequency: 868 ,663 5 MHz/AM
Battery lifet ime: appro x. 3 ye ars
Environment al cate gory: II
Temper ature r ange: –10°C to +55°C
Monta ge- en bedieningsinst ructie voor ABUS Funk -venster greep F G350E
Deze handleiding is als volgt ingedeeld
I. Algemene inf ormatie en inf ormatie o ver de b atterij
II. Mogelijkhede n om de venst er greep in te z etten
III. Inhoud van de v erpakk ing
IV. Mont agegereedschap
V. Monta ge en aanleerpr oces
VI. Het bedienen en wiss elen v an de batter ij
VII. Technische geg evens
I. I. Algemene inf ormatie en i nform atie over de batterij
Dit product voldoet aan de eis en van de g eldende Europe se en nationale ric htlijnen.
De conformiteit is a angetoond, de v ereist e verkl aringen en de docu mentatie zijn bij de producent
(www.abus.com) in te zien.
Om deze situatie te kunnen co ntinuere n en het gebruik van het product ge vaarloos t e houden moet dege ne die dit
product gebruikt we rken met deze inst allatiehandleidin g.
Het product als geheel mag nie t wor den ver anderd resp. worden om gebouwd. Dat g eldt met name voor de int erne
antenne en de dra aicondensato r . Ook zou vinger contact me t de prin plaat moeten wor den
vermeden. Het toeg estane tempe rat uurbereik voor de i nzet van de v enster greep bed ra agt – 10°C bis +55°C bij een
maximale luchtvoch tigheid van 90%.
Noch de auteur noch ABUS-SC k an een aansprak elijkheid voo r verlie s of schade acc epteren, die dir ect of indirect
veroorzaakt is op basis v an deze inst ructie of wa arvan wor dt beweer d dat hij da ardoor is o ntstaan.
De i nhoud van deze instr uctie kan zonder voor afg aande waarsc huwing wor den ver anderd.
Veilig heid:
Het product als geheel mag nie t gewijzigd of omgebouw d worden. Oo k ving ercont act met de plati ne moet
vermeden worden.
Voorzichtig bij het gebruik v an de magneet:
• Gevaar v oor het knellen v an vinge rs!
• Product buite n het berei k v an kindere n houden omwille v an kleine onder delen die inge slikt kunnen worden.
• Voor al bij het inslik ken van de mag neet moet onmiddellij k een arts ger aadpleegd worden.
• Credit - of EC -kaarten met een ma gnetisc he strip kunnen be schadig d worde n.
• Voor per sonen met een pac emake r , debrillator of ander e geïmplanteer de toestellen g eldt: de magneet k an
dergelijk e toestellen negatief beïn vloeden. Houd daar om bij de mont age voldoende af stand (ca. 2 0 cm) tussen de
magneet e n het geïmplant eerde toest el.
Informat ie over de ba tterij:
Het product wor dt gev oed d.m. v . gelijkspanning via ee n 3,6V SAF T LS 142 50 lithiumb atterij die wordt meegelev erd.
Bij het plaatsen v an de batter ij moet wor den gelet op de a ansluiting op de juiste pole n.
Om een lange levensduur mo gelijk te mak en en br and en verwondingen te vermijde n, moet rek ening wor den
gehouden met de volgende inf ormatie:
• Volgens de we t- en r egelge ving is het v erwijder en van b atterije n via het huis vuil ver boden, die moeten wo rden
afge geven bij de be kende plaats en van i nzameling.
• Batte rijen mogen noch a an directe zonnestr alen noch aan ande re war mtebro nnen wor den blootgest eld of wor den
bewaar d op plaatsen met zeer hoge te mper aturen.
• Batte rijen hore n niet in handen van kinde ren en k unnen niet opnieuw worden opg eladen.
• Batte rijen mogen niet
• uit e lka ar wor den genomen, wo rden doorboo rt of anderszins w orden besc hadigd
• worden v erbr and
• met water in aanr aking k omen
• worden k ortgesloten
II. Mogelijkheden om de venster greep in t e zett en
De d ra adloze venst er greep FG35 0E biedt - behalve de nor male bediening v an een venster dat me t een
draai-k antelbesla g dat met een h and kan worden bediend - de f unctionaliteit van een k lassieke ope ningsmelder
alsmede detectie van de gr eepstelling; die k an als toestandsmelding (ve nster geopend of venster ver grendeld) wor den
gemeld, en wel aan de separ ate ABUS dra adloze displa ymodule F A 01 en/of ee n opening aan de ABUS – Secvest
alarmcentr ale, aan de IP alarmmodule (CA SA10010 ) en via een dr aadloze uitbreidings module (AZ4 120 of AZ4220 ) ook aan
de via k abel verbo nden ABUS T erxon-alar minstallatie MX en LX.
De draadloz e reikwijdt e binnen in het gebou w bedr aagt c a. 30 meter e n is aankelijk van de bou wconstructie van
het gebouw alsmede de over ige omst andigheden te r plaatse.
III. Inhoud van de ver pakkin g (A. 1)
1. Draai greep 6. Magneethouder
2. Elektronische eenheid 7 . Bevestigin gsschroef 2, 9 x 16 mm
3. Batter ij 8. Vierk antsti, v er grendelsc hijf en
4. Magneethouderbe vesti ging bevestigingss chroe ven M5 x 3 5 mm en M5 45 mm
5. Basis 7 mm 9. Opzetstukk en (2 stuks)
IV. Mon tag egereeds chap
• Kruiskop- e n platte schr oev endr aaier
V. Monta ge en aanleerproce s
V . 1. Montage:
Voor de montag e van de F G350E moet de best aande gr eep in open positie wor den gebr acht en worden
gedemonteerd.
• Elektr onische eenheid met pl atte schr oevend ra aier uit de gr eep losmake n (zie a. 3).
• Le ngte v an de vierk antsti me t ver grendelschijf ( 8) aan de h and van de oude gr eep instellen (a . 2).
• W anneer de doorsnede van de bev estigin gsgaten i n het venst er gelijk aan of gr oter dan 12 mm zijn,
opzetstukke n (9) op de nok ken van de gr eep steke n.
• FG350E in hor izontale posit ie breng en en met 2 schr oeve n M5 x 3 5 mm of M56 x 45 mm mo ntere n.
• Mon tage van de mag neethouder: Magnee thouderbev estigin g (4) en ba sis 7 mm (5) kunne n met de
aangebrac hte plakfolie s zonder sc hroef wo rden bev estig d, wij r aden echter de schroef monta ge aan (voor boren
b ij k un st sto f niet nodi g). De basis 7 mm k an bij sponninghoogten van af 20 mm de funct ie van het maagneet contact
verbetere n (zie a. 5).
• Posit ie van de ma gneethouder: Midden ma gneethouder t er hoogte v an de onderk ant van de sokk el v an de
greep (zie a. 5)
• Af stand tot de venstervleugel a an de zijk ant: max. 3 mm (zie a . 5).
• Ma gneethouder ( 6) er opdrukk en.
V.2. aanleerpr oces:
• Bij F A 01 of Secvest al armcentr ale / IP-alarmmodule / dra adloze T erxon-uit breidinge n moet de zone wo rden
vast gelegd, waarop de FG350E moet worden a angeleer d (zie daarvoor de montage´-i nstructie v an het
desbetr eende apparaat).
• Batt erij met de polen in de juist e positie in de elektr onische eenheid le ggen (A. 5)
• Sabotag eschak elaar k ort handmat ig drukk en en weer loslaten (A. 5 )
• Door het opene n van het contact wordt de F G350E met een d ra adloos signa al aan F A 01 of Se cvest
alarmcentr ale IP/ IP-alarmmodule / dr aadloze Terx on-uitbreidi ngen aang eleerd (A. 5 ). Bij de dr aadloze
Terxonuitbr eidingen moet de component v ia de LED wor den aangeleer d (Kijk d aarvoor in de mo ntage-
instructie van de desbe tree nde dr aadloze uitbr eiding).
• Aan FA 01 of Secv est alarmce ntr ale / IP-alarmmodule / dr aadloze Terx on-uitbreidi ngen wor dt het f eit dat he t
aanleren is gelukt ak oestisch ge meld.
• Na het sig naal v an het FG350E a an FA 01of Secv est alarmce ntr ale / IP-alarmmodule / dr aadloze
Te rxonuitbr eidingen dat het aanler en is gelukt de ele ktronisc he eenheid in de juiste positie in de
greep schuiven (A . 6).
• Voor het aanleren van ander e FG350E de de sbetre ende zones k iezen, Ga te werk v olgens punt V .2.
• Er k an maar één FG3 50E per zo ne worde n aangeleer d (met uitzonder ing v an Secvest IP:
hier kunnen tot 3 , resp. 4 me lders per zo ne worde n aangeleer d) maar een F G350E k an zowel aan F A 01 als ook
aan Secvest alarmc entr ale / IP-alarmmodule / dr aadloze uitbreidingen van T erxon worde n aangeleer d.
V.3. Infr arooddiode (A .5) voo r het aanler en in de door k abel verbonden ABUS Terx onalarminstallatie vi a separ ate
dr aadloze uitbreidingsmodule:
• Zie productpr ogr amma ABUS Security -Center .
• Inform atie over de installatie is t e vinden in de docume ntatie m.b. t. de T erxon alar minstallatie .
VI. Het bedienen en het wisselen van de ba tterij
VI. 1. Bedieni ng:
De draadloze venster greep FG350E biedt – beh alve de normale bedie ning v an een venst er dat met een
draai-k antelbesla g dat met ee n hand k an worden bedie nd - de functionaliteit van ee n klassiek e
openingsmelder alsmede detect ie van de gr eepstelling e n kan die als toe standsmelding (v enster g eopend
of venster ver grende ld) melden aan de separ ate ABUS dr aadloze displa ymdule F A 01 en of een opening aan
de ABUS – alarminstallat ie Secvest alar mcentr ale / IP-alarmmodule en via een dr aadloze
uitbreidingsmodule ook aan de via een k abel ve rbonden ABUS al arminstal lat ie van Terx on.
Daarbij geldt:
Venster par allel tot de venster omlijsting en gr eep in v er grendelste lling (venst er gesloten) –> zone
gesloten (of LED groen bij F A 01). Alle daarvan afwij kende sce nario’s –> zone open (of LED rood op F A 01).
VI.2. batterij verwisselen:
• De batt erijstatus van het F G350E wor dt met het draadloze signaal ov ergedr agen.
• De noodzaak o m de batter ij te wisselen wordt a angege ven vi a een melding (le ge batter ij) aan F A 01 of
Secvest alarmcent rale / IP-alar mmodule /Terx on.
• Als de FG350E in de ABUS alarminst allatie Secv est alarmce ntr ale / IP-alarmmodule / dr aadloze
Terxon-uitbr eidingen is a angeleer d moet de alarminst allatie voo r het wisse len van de b atterij i n de
instellingsmodus wor den gebr acht, omdat e r anders alarm zou kunnen wo rden gesla gen door het
gebruikte sabota gecontact (zie daarvoor de bedie ningsinstructie van de desbet ree nde alarminstall atie).
• Voor het wisselen v an de batt erij met een k leine kruisk opschr oevendr aaier de ver grendeling v an de
elektronische eenheid losdr aaien (A. 7)
• De elektr onische eenheid er uit trek ken.
• Oude batte rij verwijde ren en de nieuwe b atter ij zo plaatsen dat hij aansluit op de juistepolen
(aeelding) (zone-indeling blij best aan).
• Vervolge ns de elektronis che eenheid er w eer in de juiste positie s chuiven, w aardoor de
sabotagesc hakela ar opnieuw w ordt in gedrukt (zone-i ndeling blij best aan).
• De instellin gsmodus van de des betre ende alarminst allatie k an nu weer w orden v erlaten.
VII. T echnische geg evens
Spanningsverzor ging: 1 x 3 ,6V Lithiu m-Thionylchlor ide
Type b atterij: SAFT L S1425 0
(Gebruik alleen dit t ype batt erij de goede
werkin g van de app arat uur te wa arbor gen
Frequentie: 868 ,663 5 MHz/AM
Levensduur b atterij: ca. 3 jaar
Milieuklasse: II
Temper atuurber eik: –10 t ot +55°C
150924-Montageanleitung-Rita.indd 1 24.09.15 10:07