3. Defrost indicator
4. Memory indicator
5. Water tank full indicator
6. Memory button
7. Humidity up button
8. Humidity down button
9. ON/OFF (power) button
OPERATION
1. Plug the unit into a suitable mains socket (please refer
to the rating label on the backside of the unit to check the
appropriate voltage/frequency).
2. Press ON/OFF button to turn on the unit. When turning
on the unit for the rst time, if press only ON/FF button but
not set the Memory, the compressor will start (provided the
room humidity is higher than 50%).
3. Press the buttons Humidity up and Humidity down to
set the required humidity. The setting range is 40%~80%,
1% will be added or reduced for each press. The set hu-
midity will show on the LED display for 8 seconds, after
that the display will return to show the room humidity. Once
the set humidity is achieved, the compressor stops working
automatically.
Humidity range is 35%~95%, when the room humidity is
less than 35%, the LED display shows “LO”, when the
room humidity is higher than 95%, it shows “ HI”.
4. Press ON/OFF button again to turn off the unit.
5. When unit is turned on for the rst time or immediately
after shutoff, there is 3 minute delay protection for com-
pressor.
DEFROST
Unit is equipped with the Hot Gas Defrost function. After
running for 30 minutes, the coil sensor detects the coil tem-
perature. If the coil temperature is ≤-1°C, the unit switches
to the hot gas defrost mode, and the Defrost indicator is
on. During the defrost process, the compressor and the
fan keep running. It takes 5 minutes to defrost (if the coil
temperature raises up to 10°C, the unit drops out of the
defrost mode automatically).
MEMORY
By pressing Memory button, the memory indicator is on,
and the unit remembers the last settings.
HOUR COUNTER FIG. 5
1. A special hour counter serves to count the operation
time of the machine.
2. 7-digit display counts off the operation time, it goes on
continuously, never gets back to “zero”.
6. DRAINAGE
Please note that in case the water tank is not positioned
appropriately, the water full indicator turns red. When the
water tank is full, the compressor stops, as a protective
measure, the “Water Tank Full” indicator turns red and
buzz.
To remove the water tank, pull it out carefully from the unit,
make sure it does not tilt over.
After empting the water tank, place the water tank into the
dedicated space. Make sure it is positioned properly, only
then the ’water full’ indicator is off and your dehumidier
can start working. (FIG. 6)
CONTINUOUS DRAINAGE
When the dehumidier works in extremely high humidity
levels, the water tank requires more frequent drainage. In
this situation, it may be more convenient to set the unit up
for continuous drainage, according to the following proce-
dures:
Remove the drain knob and rubber plug and retain for
future use.
Connect the drain tube to the water outlet (FIG. 7) and
put the other end into a drain.
7. MAINTENANCE
Always unplug the unit from the mains supply before car-
rying out any maintenance or cleaning of the unit.
CASING CLEANING
Use soft cloth to clean the unit.
Don’t ever use volatile chemicals, gasoline, detergents,
chemically treated clothes, or other cleansing solutions as
they may damage the casing.
FILTER CLEANING (FIG. 8)
Extract the lter from the unit.
Use a vacuum cleaner or tap the lter lightly for easy
cleaning. If the lter is excessively dirty, use warm wa-
ter with a small amount of medium strength detergent.
Make sure the lter is completely dry before installing
it back.
Do not expose the lter to sunlight.
STORAGE
If the unit is not used for an extended period of time, please:
Turn off the unit, unplug it and take away the AC cord.
Empty the water tank completely and dry it.
Cover the unit and store it in a place not exposed to the
direct sunlight.
8. TROUBLE SHOOTING
THE UNIT DOES NOT OPERATE:
Is the unit plugged in?
Is the house electricity on?
Is the room temperature below 5
O
C or above 32
O
C? If
so, then it is out of the working range of the unit.
Make sure the ON/OFF switch is turned on.
Check if the water tank is positioned properly inside the
unit and if it is not full.
Make sure the air inlet and outlet are not obstructed.
THE UNIT SEEMS TO DO NOTHING:
Is the lter dusty, contaminated ?
Is the air intake or outlet blocked?
Is the room humidity already quite low?
THE UNIT SEEMS TO DO LITTLE:
Are too many windows or doors open?
Is there something in the room producing a lot of hu-
midity?
THE UNIT IS TOO NOISY:
Check whether the unit is positioned on a level surface.
THE UNIT IS LEAKING:
Make sure the unit is in appropriate condition.
If you are not using continuous drainage, make sure
the rubber plug (on the bottom of the unit) is in its position.
6

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

master-DH-732

Zoeken resetten

  • Beste

    Ik heb een vraagje ivm dit product er komt op mijn droger constant lo al melding wat is hier van de bedoeling
    Als ik hem aansteek heb ik ook je kan hem instellen van 40 -80 maar ik kan hem niet op 80 zetten want dan gaat hij niet aan ik kan enkel tot 50 gaan hoe komt dit Mvg Gesteld op 24-3-2020 om 09:20

    Reageer op deze vraag Misbruik melden

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw master DH 732 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van master DH 732 in de taal/talen: Alle talen als bijlage per email.

De handleiding is 2,15 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info