588472
6
Verklein
Vergroot
Pagina terug
1/12
Pagina verder
1
en
THE UNIT IS SEALED AND CONTAINS
FLUORINATED GREENHOUSE GASES
COVERED BY KYOTO PROTOCOL.
THE “GWP” IS LISTED IN THE “TECHNICAL
SPECIFICATIONS TABLE”.
SAFETY WARNINGS
The dehumidier must always be connected to an
efciently grounded socket. As with all electrical
appliances, failure to observe this safety measure
is a potential source of danger that the constructor
does not respond for in any way.
The appliance must only be dismantled by a
qualied technician using the appropriate tools.
The appliance must always be in an upright position
when it is plugged into an electric socket and must
not be handled with sharp movements. Any water
leaking from the dehumidier could wet the electric
parts with the obvious risk of danger, therefore the
dehumidier must always be unplugged before it is
moved and the tank emptied [if present] before it is
lifted.
Should any water be spilt due to sharp movements,
the dehumidier must remain turned off and
unplugged in an upright position for at least eight
hours before it can be turned on again.
This dehumidier takes the air in from the rear and
expels it through the front grid, and therefore the
rear panel which holds the air lter must be at a
distance of at least 15 centimetres from the wall.
The appliance must not be turned on in conned
spaces where the expelled air from the front grid is
unable to circulate freely, however the side panels
can be placed next to a wall without affecting the
appliance efciency.
This dehumidier has been constructed to the
strictest safety standards. No sharp items (such as
screwdrivers, knitting needles or similar objects)
must be introduced into the front grid or the opening
in the rear panel when the lter is removed as that
is extremely dangerous for human safety and can
damage the appliance.
Do not wash the appliance with water; just use a
damp cloth after unplugging it from the socket.
Do not cover the front grid with clothes or other
items as this could damage the appliance and be a
source of danger.
Clean the lter periodically; on average once a
month but if the dehumidier is used in very dusty
surroundings the lter should be cleaned more
frequently. Refer to the specic lter cleaning
chapter. When the lter is dirty the expelled air is
hotter than normal and can damage the appliance
and reduce its efciency.
DEHUMIDIFIERS
DESCRIPTION
All dehumidiers use cooling cycles with compressor. The
appliances are described below.
FUNCTIONS
This dehumidier is an appliance working with a cooling
cycle based on the physical principle whereby the air is
exposed to a cold surface and wets it, giving off humidity
as drops of condensation, or ice if the room temperature
is very low.
In practice, a cooling machine keeps a coil cold that the
air is passed through and therefore the air cools down and
has the humidity removed. The air then passes through a
hot heat exchanger and is heated up to return to the room
dehumidied and slightly warmer than at the beginning.
Refer to the diagram (Fig. 1-2):
The air is taken in from the rear of the appliance and
passes through the lter (1), the cold aluminium coil
(evaporator) (2), the hot exchanger (condenser) (3), the
fan (4) and nally the dehumidied air is expelled into
the room through the front grid. The condensed water is
collected in the tank (5) [if present] or discharged by the
specic pipe. A micro-switch (6) stops the appliance when
the water in the tank reaches a set level [if present]. The
moisture gauge (7) enables the dehumidier to work when
the room humidity is higher than the required level. An
electronic board (8) controls the defrosting and prevents
any dangerous starting of the compressor (9) too soon
and delays its ignition.
These appliances have hot gas defrosting devices
installed, with a solenoid valve for the hot gas bypass,
a special electronic board (with double relay) and a
defrosting thermostat.
This defrosting system is exclusive to our appliances:
in practice, a system with a thermostat and electronic
control that uses the hot gas bypass only for the time
that is strictly needed. This allow to extend the life of the
appliance and reduces the time of the hot gas phase.
CONTROL PANEL
The control panel is in the front of the appliance and
contains four lighted signals (Fig. 3):
DEFROST (red led): Comes on when the compressor
is on pause or the rst ignition is delayed or during the
defrosting phase.
WORKING (red led): Comes on when the humidity gauge
requests the appliance functions.
POWER (red led): Comes on when the appliance is
powered.
FULL (green led): Comes when the condenser tank is
full [if present]; when this light is on the appliance stops/
does not work.
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw master DH 44 INOX bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van master DH 44 INOX in de taal/talen: Duits, Engels als bijlage per email.

De handleiding is 1,64 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info