4. The unit will shut down automatically after the SLEEP
function running for 12 hours.
5. Please note, the sleep function is not available while the
machine is working in ventilation. Only available in
Cooling or Heating mode.
6. When the machine is in Sleep function, the ventilation
would turn to be LOW.
Heating function (This is optional, only for cool & heat
model.)
1. When using Heat Pump, the ambient warm air is recycled
and use to heat the area where it is required. The Exhaust
Pipe must be fitted firmly to allow the cold air to be
removed outside.
2.
3. Continuous drain is compulsory while the unit is in heat
mode. Working range for heating function is 5 to 27oC.
For temperature outside this range, the unit may not work
properly.
TiO2 / Ionizer function (option)
1. This is only for the model with TiO2 or Ionizer function,
i.e. model no. with T or I. T stands for TiO2 (ultra-violet)
, I stands for Ionizer.
2. To start the TiO2 or Ionizer button, please press
TiO2/Ionizer button. These two functions can clean the air,
improve the air quality.
Regulating air flow direction
Adjust the air louvers by hand to control the air flow direction.
(Fig. 23)
Self-diagnosis
This machine is equipped with self-diagnosis function. If
something is wrong in the machine, the display window will show
the word “E1” or “E2”. As this time, please call your service
centre.
All the above functions can also be performed with the supplied
remote control. (Fig. 24)
This remote control requires one button cell (No.CR2025) to
operate
NOTICE !
1. To prolong the compressor's life, after switch-off of the
unit, please wait for 3 minutes (at least) before re-switch.
2. The cooling system will switch off if the ambient
temperature is lower than the set one. The ventilation,
however, keeps working on the set level. If the ambient
temperature rises above the selected level, the cooling will
return to work.
3. On the contrary, the heating will switch off if the ambient
temperature is higher than the set one (still, the ventilation
keeps working on the set level). As the ambient
temperature drops below the selected level, the heating
will return to work.
4. This machine is equipped with ANTI-FROST function.
While using the heating function during low temperature,
sometimes the heating will stop for a while in order to melt
the frost. As this occurs, just wait for the heating returns
to work.
DRAINAGE
During the process of cooling, some water will be extracted from
the air into the unit. If the tank is full, both of the compressor and
motor will stop. The “water full” sign will light on, also the
machine will beep as reminder.
To make the cooling work again, please empty the water by one of
the following ways:
Fig. 25
1. Turn off the air conditioner and avoid moving it when full.
2. Position a container (a water tray for example) underneath
the drain hole.
3. Remove the drain knob & rubber plug from the drain hole
and allow the water to drain out.
4. When the container is almost full, replace the rubber plug
in the drain hole and empty the water tray.
5. Repeat until the unit is emptied.
6. Replace the rubber plug and tighten the drain knob firmly.
7. Switch on the unit - the full water or compressor operating
indicator should not be flashing.
If you wish to operate the unit without the need to empty the water
tank, please:
Fig 26.
Remove the drain knob and rubber plug and retain for
future use.
Connect the drain tube supplied to the water outlet as
shown and locate the other end into a drain.
Fig. 27.
The drain tube may be extended by adding an extension
tube and using a suitable connector.
Please note (Fig. 28.)
1. The drain must be at or below the outlet level.
2. Flashing comp / ‘full water’ indicator will not function in
this mode of drainage.
3. If you want to extend the water tube, you can connect it
with another tube (OD: 18mm)
Special caution for heating function !(fig. 29)
While using the heating function, please note:
1. Install the exhaust pipe well, in order to exhaust the cool
air to outdoor. (Please refer to the instruction manual for
installation method.)
2. Fix the drainage to be continuous one (i.e. drain the water
by water tube).
3. Working range for heating function is 7 to 27oC (for
cooling function, it is 18 to 32oC). For temperature outside
this range, the unit may not work properly.
MAINTENANCE
Always unplug the air conditioner from the mains before
cleaning. To maximize the efficiency of the air conditioner
clean regularly.
Cleaning the housing
Use a soft, damp cloth to wipe the body clean.
Never use aggressive chemicals, gasoline, detergents, chemically
treated cloths, or other cleansing solutions. These all could
possibly hurt the cabinet.
Cleaning the filter
Use a vacuum cleaner or tap the filter lightly to remove loose dust
and dirt from the filters and then rinse thoroughly under running
water (no hotter than 40oC).
Dry thoroughly before replacing.
Notice! Never operate the unit without the filters.
End of season storage (fig. 30)
Drain any water in the unit before completely operating the
unit on ventilation only mode for a few hours, to
thoroughly dry the inside.
Clean or change the filter
Unplug and store the power cord as shown
Cover the cord storage
26

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw master AC 1600 E bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van master AC 1600 E in de taal/talen: Duits, Engels, Italiaans, Pools, Deens als bijlage per email.

De handleiding is 2,86 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info