Whendrawingoutthepowercableyouhaveto
payattentiontoyellowbandindicatingtheend
ofthecabledrawnout.Furtherattempts(jerks)
mayleadtodamageofthecable.
7
Plug the cord into an AC outlet.
Before you start vacuum cleaner make sure whether the dust
container “CYCLONE” is mounted in chamber of the vacuum
cleaner, and whether the inlet and outlet lters are mounted
in the vacuum cleaner.
8
Start the vacuum cleaner by pressing On/Off button (4).
9
Vacuum cleaner is equipped with electronic power
regulator, which - during the vacuuming - can smooth control
the suction power of vacuum cleaner. By turning the knob
(4) right or left you can increase or decrease the suction
power.
10
Vacuum cleaner is also equipped in mechanical control
of suction power (9), which is located on the handle of the
hose. It can temporarily slightly adjust the suction power,
without adjustment done with knob (4).
Disassembly/assembly of “CYCLONE”
dust container
Vacuum cleaner is equipped in removable dust container
“CYCLONE” (which is a removable segment of vacuum
cleaner), which accumulates contaminants. As soon as the
“CYCLONE” dust container is full, it should be emptied.
Vacuum cleaner is equipped with a safety
valve whichis locatedin thechamber ofthe
“CYCLONE” dust container. The valve is
activated (open) automatically when a total
jam (occlusion) occurs on the sucking hose
orthishappenstoequipmentconnectedtoit,
aswellasin thecaseofexcessiveoverllof
“CYCLONE” dust container. When the valve
is open you can hear a characteristic sound
(“asoundofutter”)inthevacuumcleaner.
1
Vacuum cleaner is equipped with a dust container
“CYCLONE” full indicator (5). When the gap of dust container
“CYCLONE” full indicator is totally lled with red mark during
operation (vacuum cleaner operates at full power and
sucker nozzle or brush is upraised over cleaned surface)
so this informs that there is a need to empty the dust bin
“CYCLONE”. The dust container “CYCLONE” full indicator
(5) may work also in the case of clogging of the suction hose
or clogging of equipment connected to the hose.
2
Switch off the vacuum cleaner by pressing On/Off
button (4).
3
Take off the cable connection plug from the wall outlet.
4
Press the two side buttons on the hose end , then remove
the hose end from vacuum cleaner inlet hole.
5
Raise the hook to unlock the dust container “CYCLONE”
(7) and remove dust container “CYCLONE” (16) from the
vacuum cleaner.
C
6
Move the dust container “CYCLONE” on garbage trash.
Press the button located on dust container “CYCLONE”, the
bottom of the container will open and the contents will fall out
to the trash.
7
After emptying the container, snap the bottom. Pay
attention to the fact that a seal located on the bottom of
container must be correctly positioned.
Containermustbepreciselyclosed.Otherwise
the dust will penetrate the vacuum cleaner
chamberandthesuctionpowerwilldecrease.
8
Insert the empty dust container “CYCLONE” to vacuum
cleaner. The characteristic “click” indicates that container
has been mounted correctly.
Emptying the dust container “CYCLONE” is necessary when
you notice that:
a) “CYCLONE” dust container full indicator indices turned on,
b) sucking power of vacuum cleaner decreased,
c) dust container “CYCLONE” is full.
Disassembly of lters
In case of dirty lters: inlet lter, foam lter
(15),HEPAinletlter(14),outletfoamlter(13),
“Microlter” (12) you can replace them with
new lters, clean them or rinse with running
water.
Donotwashthelterinthewashingmachine
ordishwasher.
Filterscanbedriedinnaturalwayonly.
Do not dry the lters using hairdryers, on
heatersandradiators.
Before replacement of lters make sure that
vacuumcleanerisswitchedoffandconnection
cableplugispulledoutfromthewalloutlet.
INLET FILTER HEPA AND FOAM INLET FILTER
Vacuum cleaners are equipped with outlet lter HEPA (High
Efciency Particulate Air) type H10 or H13.
These lters have exceptionally high ltration capacity, are
made of special bers, which can retain almost all dust
particles. The lter standards H10 and H13 dene the
permeability of the lter: H10 lter can retain 85% of particles
diameter of 0.3 microns, and H13 lter up to 99.95% of all
impurities.
It is necessary to clean periodically the inlet lter HEPA (14)
in order to remove minor fractions of the dust, and foam inlet
lter (15) must be also cleaned.
Disassembly the “CYCLONE” dust container and empty it in
accordance with paragraph (C).
1
Remove the HEPA foam inlet lter (14) from “CYCLONE”
dust container
2
Remove foam inlet lter (15). If the foam inlet lter (15)
is dirty, you can replace it with a new lter, you can clean
D
62

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Zelmer Eco Power VC3100.0 SK bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Zelmer Eco Power VC3100.0 SK in de taal/talen: Engels, Pools als bijlage per email.

De handleiding is 4,1 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info