539663
43
Verklein
Vergroot
Pagina terug
1/46
Pagina verder
49
2750-001_v04
The basic HEPA (High Efciency Particulate Air) washable
class H12 lter is located at the outlet of the cyclone lter
container. The HEPA 12 washable lter is made of a special
ltration material which enables to rinse the lter under
running water once it becomes dirty and to reuse the lter.
An outlet HEPA class H11 lter (nonwashable) is located at
the outlet of the vacuum cleaner.
The lters have a high ltration capacity; they are made of
special bers which are able to retain almost all dust particles
greater than 0.3 micron. The H11 and H12 classes determine
the ltration effectiveness of a given lter. The HEPA H11
and H12 lter retains 95.5% of particles with the size of 0.3
micron.
Before changing the lters make sure that the vacuum
cleaner is switched off and unplugged from the mains
supply.
BASIC HEPA 12 FILTER
It is necessary to periodically clean the basic HEPA 12 ler
from ne dust fractions.
Dismantle the “CYKLON” dust container and empty the
container according to the instructions in section (E).
1
Turn the basic HEPA 12 lter in the UNLOCK direction
and remove the lter.
2
Remove the protective mesh of basic lter (14).
Clean the mesh and dry it thoroughly. Replace the mesh
if damaged.
Duetosafetyreasonsitisprohibitedtoinstall
amoistprotectivemesh.
Clean the pleats of the basic HEPA 12 lter
(13). The
lter can be washed under running water. Thoroughly dry
the lter. In case of damage to the lter pleat, the lter
must be replaced with a new one.
Duetosafetyreasonsitisprohibitedtoinstall
amoistordamagedbasicHEPA12lter(13).
3
After cleaning and drying the protective mesh and the
basic HEPA 12 lter, install the protective mesh on the HEPA
12 lter and insert the whole unit to the “CYKLON” dust
container.
4
Press the interlock button and turn the basic HEPA 12
lter (13) in the LOCK direction.
Insert the “CYKLON” dust container together with the
installed basic HEPA 12 lter (13) into the vacuum cleaner
chamber and close the cover by pressing it until you hear
a characteristic “click” according to section (E).
HEPA 11 OUTLET FILTER
1
To replace the HEPA 11 lter lift the vacuum cleaner
handle and open the accessory compartment.
2
Grab the lter cover by the fastening, rmly pull with the
thumb and lift it upwards.
3
Remove the HEPA 11 lter case and replace it with a new
one. The HEPA lter ensures an effective operation of the
vacuum cleaner for about 1 year.
4
Insert the cover so that the two protrusions in the lower
part of the cover are inserted in the openings of the vacuum
cleaner body, press the lter cover so that the rear fastenings
snap shot on the body.
INLET FILTER
Release the upper cover fastening
(12) and open the
cover.
Remove the SAFBAG dust bag module/the “CYKLON”
dust container from the vacuum cleaner chamber.
1
Slide the inlet lter casing with the installed inlet lter
from the tracks on the back side of the vacuum cleaner
chamber.
2
Remove the inlet lter (19) from the inlet lter casing.
3
Place the new lter in the inlet lter casing (20) with the
material side directed towards the inside of the casing.
4
Slide the inlet lter casing (20) together with the lter in
the tracks until stop to the previous position.
Alwaysreplaceadamagedinletlter(19)with
abrandnew,originalone.
Insert the SAFBAG dust bag module/the “CYKLON” dust
container into the vacuum cleaner chamber.
Close the cover by pressing it until you hear
a characteristic click.
Special accessories
The following special accessories may be purchased in retail
outlets:
Zelmer turbobrush (25)
May be used with all types of ZELMER vacuum cleaners. Is
used for an effective vacuuming of carpets and tted carpets.
While using the turbobrush follow the instruction manual.
The use of the turbobrush decidedly increases the
effectiveness of removing brous dirt such as: animal hair,
hair, threads etc. It is practically useful in households with
pets (cats, dogs), where removing the animal hair from the
carpets and oorings is very onerous.
End of operation cleaning and
maintenance
1
Switch off the vacuum cleaner by pressing the “on/off”
button (7).
2
Unplug the appliance.
3
Wind the cord by pressing the cord rewind button (4).
While doing this hold the cord to make sure it is not tangled
and the plug does not hit the vacuum cleaner housing.
4
Disconnect the telescopic tube from the nozzle or brush.
5
Disconnect the telescopic tube from the hose. In order to
remove the tube from the hose handle press the “A” locking
device and pull the tube in the direction of the arrow.
6
Press the two side buttons on the end of the hose and
remove the hose end from the inlet opening of the vacuum
cleaner.
H
D
F
G
43

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Zelmer Clarris Twix 2750.0 SP bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Zelmer Clarris Twix 2750.0 SP in de taal/talen: Engels, Pools als bijlage per email.

De handleiding is 3,21 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info