030n30200..7FIns. Param.1 MSBRefer to the Ef. Parameter List
00..7FIns. Param.1 LSBRefer to the Ef. Parameter List
030n32200..7FIns. Param.2 MSBRefer to the Ef. Parameter List
00..7FIns. Param.2 LSBRefer to the Ef. Parameter List
030n34200..7FIns. Param.3 MSBRefer to the Ef. Parameter List
00..7FIns. Param.3 LSBRefer to the Ef. Parameter List
030n36200..7FIns. Param.4 MSBRefer to the Ef. Parameter List
00..7FIns. Param.4 LSBRefer to the Ef. Parameter List
030n38200..7FIns. Param.5 MSBRefer to the Ef. Parameter List
00..7FIns. Param.5 LSBRefer to the Ef. Parameter List
030n3A200..7FIns. Param.6 MSBRefer to the Ef. Parameter List
00..7FIns. Param.6 LSBRefer to the Ef. Parameter List
030n3C200..7FIns. Param.7 MSBRefer to the Ef. Parameter List
00..7FIns. Param.7 LSBRefer to the Ef. Parameter List
030n3E200..7FIns. Param.8 MSBRefer to the Ef. Parameter List
00..7FIns. Param.8 LSBRefer to the Ef. Parameter List
030n40200..7FIns. Param.9 MSBRefer to the Ef. Parameter List
00..7FIns. Param.9 LSBRefer to the Ef. Parameter List
030n42200..7FIns. Param.10 MSBRefer to the Ef. Parameter List
00..7FIns. Param.10 LSBRefer to the Ef. Parameter List
TOTAL SIZE 14
For effect types that do not require MSB, the Parameters for Address 02-0B will be received. Address 30-42 will not be received.
For effect types that require MSB, the Parameters for Address 30-42 will be received. Address 02-0B will not be received.
When Bulk Dumps that include Effect Type data are transmitted, the Parameters for Address 02 - 0B will always be transmitted. But, effects that require MSB, when the bulk dump is received the
Parameters for Address 02 - 0B will not be received.
n = Insertion Effect No. (0 - 2)
The INSERTION EFFECT Parameter cannot be reset to its factory settings with XG SYSTEM ON or XG ALL PARAMETER RESET, there is no default value.
When a Parameter Request or Bulk Request message is received, the currently set value is always transmitted.
040000200 - 7FInsertion Effect Type MSBRefer to the XG Effect Map
00 - 7FInsertion Effect Type LSB00 : basic type
02100 - 7FInsertion Effect Parameter1Refer to the XG Ef. Parameter List
03100 - 7FInsertion Effect Parameter2Refer to the XG Ef. Parameter List
04100 - 7FInsertion Effect Parameter3Refer to the XG Ef. Parameter List
05100 - 7FInsertion Effect Parameter4Refer to the XG Ef. Parameter List
06100 - 7FInsertion Effect Parameter5Refer to the XG Ef. Parameter List
07100 - 7FInsertion Effect Parameter6Refer to the XG Ef. Parameter List
08100 - 7FInsertion Effect Parameter7Refer to the XG Ef. Parameter List
09100 - 7FInsertion Effect Parameter8Refer to the XG Ef. Parameter List
0A100 - 7FInsertion Effect Parameter9Refer to the XG Ef. Parameter List
0B100 - 7FInsertion Effect Parameter10Refer to the XG Ef. Parameter List
0C100 - 7FInsertion Effect PartPart1...16(0...15)
AD1(64)
OFF(16...63, 65...127)
0D100 - 7FMW Insertion Control DepthDon’t care
0E100 - 7FBEND Insertion Control DepthDon’t care
0F100 - 7FCAT Insertion Control DepthDon’t care
10100 - 7FAC1 Insertion Control DepthDon’t care
11100 - 7FAC2 Insertion Control DepthDon’t care
TOTAL SIZE12
040014100 - 7F
Unique Insertion Effect External
1...16(0...15), off(127)
Control CH1(Harmony Channel)
15100 - 7F
Unique Insertion Effect External
1...16(0...15), off(127)
Control CH2 (MELODY CHANNEL)
TOTAL SIZE2
040020100 - 7FInsertion Effect Parameter11Refer to the XG Ef. Parameter List
21100 - 7FInsertion Effect Parameter12Refer to the XG Ef. Parameter List
22100 - 7FInsertion Effect Parameter13Refer to the XG Ef. Parameter List
23100 - 7FInsertion Effect Parameter14Refer to the XG Ef. Parameter List
24100 - 7FInsertion Effect Parameter15Refer to the XG Ef. Parameter List
25100 - 7FInsertion Effect Parameter16Refer to the XG Ef. Parameter List
TOTAL SIZE6
Insertion Effect Type MSB:Assigns the Harmony Mode.
If the value is not a Harmony Mode value, the Harmony function will be OFF and the input signal will be transmitted as is.
Insertion Effect Type LSB:Assigns the Harmony Kit.
If the value is not an existing harmony kit value, don’t care.
Harmony Channel:Harmony control channel.
Melody Channel:Melody play channel.
When both are received, the last message received will take priority.
For example, when the Melody Channel is 3 and the Harmony Channel 3 message is received, the Melody Channel will be OFF and the Harmony Channel will be 3.
Note) The SPECIAL EFFECT Parameter cannot be reset to its factory settings with XG SYSTEM ON or XG ALL PARAMETER RESET, there is no default value.
When a request message is received, the currently set value is always transmitted.
Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.
Product:
Spelregels forum
Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:
lees eerst de handleiding door;
controleer of uw vraag al eerder door iemand anders is gesteld;
probeer uw vraag zo duidelijk mogelijk te stellen;
heeft u een probleem en al geprobeerd om dit op te lossen, vermeld dit erbij aub;
heeft u een oplossing gekregen van een bezoeker dan horen wij dat graag in dit forum;
wilt u een reactie geven op een vraag of antwoord, gebruik dan niet dit formulier maar klik op de knop 'reageer op deze vraag';
uw vraag wordt direct op de website gezet; vermijd daarom persoonlijke gegevens in te vullen;
Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.
Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.
Abonneren
Abonneer u voor het ontvangen van emails voor uw Yamaha CVP-109 bij:
nieuwe vragen en antwoorden
nieuwe handleidingen
U ontvangt een email met instructies om u voor één of beide opties in te schrijven.
Ontvang uw handleiding per email
Vul uw emailadres in en ontvang de handleiding van Yamaha CVP-109 in de taal/talen: Duits als bijlage per email.
De handleiding is 3,25 mb groot.
U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.
Uw handleiding is per email verstuurd. Controleer uw email
Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.
Er is een email naar u verstuurd om uw inschrijving definitief te maken.
Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken
U heeft geen emailadres opgegeven
Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.
Uw vraag is op deze pagina toegevoegd
Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.